Compressor Intake and Air Quality Red Flags

PSDA Safety Inspector Exam · Put your knowledge to work in context.

All case studies

Compressor Intake and Air Quality Red Flags

During an unannounced inspection of a dive shop supporting recreational and working divers, you find a portable compressor housed in a lean-to beside the building's parking area. The intake hose is coiled near a diesel generator exhaust and a refuse bin. The compressor log shows the last filter change 14 months ago, with 62 hours since; the manufacturer's interval is 50 hours or 6 months. The most recent air quality test is 8 months old and reports CO at 12 ppm, CO2 at 900 ppm, and oil mist at 0.3 mg/m³. The shop's written program requires quarterly testing and a CO limit of 10 ppm. No continuous CO monitor is installed. The fill operator says the test 'passed' because it was under the old limit. Cylinders filled that morning are stacked for delivery. You must decide whether to quarantine cylinders, stop filling, and what records to demand.

1. Determine whether the cylinders filled that morning may be released, and what immediate controls you would impose.

Read the worked answer

Do not release the cylinders. The air test is 8 months old against a quarterly requirement, the filter is 14 months/62 hours against a 50-hour or 6-month interval, and the intake is beside a diesel exhaust. The recorded CO of 12 ppm exceeds the shop's own 10 ppm limit, so the operator's 'passed' conclusion is wrong on the program's terms. Because the air may be noncompliant and the sampling interval has lapsed, the cylinders are suspect until retested. Immediate controls: stop all filling, tag the compressor out of service, segregate and quarantine the morning's cylinders, notify customers not to use them, retain the compressor log and the prior air test, and arrange testing by a qualified air-quality laboratory before any release. Also inspect the intake location and prevent operation near the generator or refuse area. Release only after a compliant test result and documented corrective actions.

2. Assess the recordkeeping and monitoring deficiencies and identify likely root causes.

Read the worked answer

The deficiencies are systemic, not a single bad reading: testing is behind schedule; filter changes are not tracked by hours or date; no continuous CO monitor provides early warning; the operator does not understand the program limit; and intake siting is uncontrolled. The air test itself shows a value above the limit, yet no one stopped filling-evidence that results are filed without review. Likely root causes include no assigned air-quality custodian, no calibration or bump-test schedule for monitors, no management review of test results, inadequate operator training on limits, and an informal culture that treats a prior 'pass' as permanent. The record review should request the last four quarterly tests, filter change records, monitor calibration records, compressor maintenance records, and the written air-quality procedure. The inspection finding should address the control system, not just the individual test.

3. Draft the inspection finding and the corrective action plan you would require before filling resumes.

Read the worked answer

Write a major nonconformity: 'Compressed breathing air was produced and cylinders were prepared for release outside the written air-quality program; recorded CO exceeded the program limit.' Corrective action plan: (1) stop filling and quarantine affected cylinders; (2) relocate the intake away from combustion exhaust and refuse; (3) service or replace filters and document hours/date; (4) install and calibrate a continuous CO monitor with alarm; (5) retest air at a qualified laboratory and compare all parameters to the program limits; (6) train the fill operator on limits, test intervals, and stop-fill authority; (7) revise the tracking system so due dates are visible; (8) audit the last 12 months of fills to identify other suspect cylinders. Verification should include a witnessed air test, record review, and interview of the operator. Filling resumes only after objective evidence that the intake, filtration, monitoring, and records are under control.