- Bioanalysis
- Related: Biological matrix, Validation, Calibration curve
The quantitative measurement of drugs, metabolites, or biomarkers in biological matrices such as plasma, serum, urine, or tissue, typically to support drug development, toxicology, or clinical decisions.
- Biological matrix
- Related: Bioanalysis, Matrix effect, Sample preparation
The complex sample material of biological origin in which an analyte is measured, for example plasma, serum, urine, blood, tissue, or saliva. Its composition strongly influences extraction and detection.
- Analyte
- Related: Internal standard, Calibration curve, Selectivity
The specific chemical or biological substance that an analytical method is designed to detect and quantify in a sample.
- Internal standard
- Related: Analyte, Matrix effect, Calibration curve
A compound added in known amount to every sample and standard to correct for variability in sample preparation, injection volume, and detector response. Stable-isotope-labeled analogs are common in bioanalysis.
- Calibration curve
- Related: Analyte, Internal standard, Limit of quantification
A plot of detector response versus known analyte concentration, generated from standards, used to relate measured signal to unknown sample concentration over a defined range.
- Limit of detection
- Related: Limit of quantification, Signal-to-noise ratio, Sensitivity
The lowest analyte concentration or amount that can be reliably distinguished from background noise, usually estimated at a signal-to-noise ratio of about three.
- Limit of quantification
- Related: Limit of detection, Calibration curve, Accuracy
The lowest analyte concentration that can be measured with acceptable accuracy and precision, typically the lowest calibration standard meeting defined criteria.
- Accuracy
- Related: Precision, Recovery, Validation
The closeness of a measured value to the true or accepted reference value, often expressed as percent bias or percent recovery.
- Precision
- Related: Accuracy, Validation, Repeatability
The degree of agreement among repeated measurements of the same sample under specified conditions, commonly reported as percent coefficient of variation.
- Repeatability
- Related: Precision, Intermediate precision
Precision obtained when the same analyst measures the same sample multiple times within a short interval using the same instrument and conditions.
- Intermediate precision
- Related: Repeatability, Precision, Validation
Precision measured across changed conditions within one laboratory, such as different days, analysts, or equipment, reflecting routine method robustness.
- Selectivity
- Related: Specificity, Matrix effect, Interference
The ability of a method to measure an analyte accurately in the presence of other sample components, including metabolites, impurities, and matrix constituents.
- Specificity
- Related: Selectivity, Interference
The ability of a method to respond only to the intended analyte and not to structurally related compounds or other sample components.
- Matrix effect
- Related: Biological matrix, Internal standard, Ion suppression
The change in detector response caused by co-eluting components of the sample matrix, which can suppress or enhance ionization or signal relative to a pure standard.
- Ion suppression
- Related: Matrix effect, Electrospray ionization, Mass spectrometry
A reduction in ionization efficiency in mass spectrometry caused by co-eluting matrix components competing for charge, leading to lower signal for the analyte.
- Recovery
- Related: Sample preparation, Accuracy, Extraction
The proportion of analyte successfully carried through sample preparation and detected relative to the amount originally present in the sample.
- Sample preparation
- Related: Extraction, Recovery, Biological matrix
The steps taken to isolate, concentrate, and clean up an analyte from a biological matrix before analysis, such as protein precipitation, extraction, or dilution.
- Protein precipitation
- Related: Sample preparation, Extraction
A sample cleanup technique in which an organic solvent, acid, or salt is added to biological fluid to denature and remove proteins, releasing the analyte into the supernatant.
- Liquid-liquid extraction
- Related: Extraction, Sample preparation
A sample preparation technique that partitions an analyte between two immiscible liquid phases based on differing solubility, allowing separation from matrix components.
- Solid-phase extraction
- Related: Extraction, Sample preparation, Recovery
A sample preparation technique in which analytes bind to a solid sorbent and are eluted selectively with solvent, enabling concentration and removal of interfering matrix components.
- Extraction
- Related: Liquid-liquid extraction, Solid-phase extraction, Recovery
The general process of separating an analyte from its sample matrix into a different phase or solvent to enable cleaner, more sensitive measurement.
- Chromatography
- Related: Retention time, Resolution, Mobile phase
A separation technique in which components of a mixture distribute differently between a mobile phase and a stationary phase, causing them to elute at different times.
- Retention time
- Related: Chromatography, Resolution
The time elapsed between sample injection and the maximum detector response for a given analyte under defined chromatographic conditions, used for identification.
- Resolution
- Related: Chromatography, Retention time, Theoretical plates
A measure of how well two adjacent chromatographic peaks are separated, calculated from their retention times and peak widths.
- Theoretical plates
- Related: Resolution, Chromatography
A measure of chromatographic column efficiency describing the number of equilibration steps, where more plates and smaller plate height indicate sharper peaks.
- Mobile phase
- Related: Chromatography, Stationary phase
The liquid or gas that carries the sample through the chromatographic system and past the stationary phase.
- Stationary phase
- Related: Mobile phase, Chromatography
The immobile packing or coating in a chromatographic column that interacts with sample components to produce differential retention.
- Mass spectrometry
- Related: Electrospray ionization, Multiple reaction monitoring, Ion suppression
An analytical technique that ionizes molecules, separates ions by mass-to-charge ratio, and detects them, providing sensitive and specific detection for bioanalysis.
- Electrospray ionization
- Related: Mass spectrometry, Ion suppression, Liquid chromatography
A soft ionization technique that generates ions from a liquid sample by applying high voltage to a sprayed aerosol, commonly coupled with liquid chromatography.
- Multiple reaction monitoring
- Related: Mass spectrometry, Selectivity, Limit of quantification
A mass spectrometry acquisition mode that monitors a specific precursor-to-product ion transition, giving high selectivity and sensitivity for targeted quantitative analysis.
- Liquid chromatography
- Related: Chromatography, Electrospray ionization, Mobile phase
A separation technique using a liquid mobile phase pumped through a packed column, widely coupled with mass spectrometry for quantitative bioanalysis.
- Validation
- Related: Accuracy, Precision, Selectivity
The documented process of demonstrating that an analytical method is suitable for its intended purpose by evaluating parameters such as accuracy, precision, selectivity, and stability.
- Stability
- Related: Validation, Biological matrix
The extent to which an analyte retains its measured concentration under defined storage and handling conditions, including freeze-thaw, bench-top, and long-term storage.
- Interference
- Related: Selectivity, Matrix effect
Any component of the sample, reagents, or system that produces a signal or alters the response of the analyte, reducing method accuracy.
- Signal-to-noise ratio
- Related: Limit of detection, Sensitivity
The ratio of analyte signal to background noise, used to judge detectability and to estimate detection and quantification limits.
- Sensitivity
- Related: Limit of detection, Calibration curve
The ability of a method to detect small changes or low concentrations of analyte, often reflected by the slope of the calibration curve.
- Quality control sample
- Related: Validation, Accuracy, Calibration curve
A sample of known analyte concentration analyzed alongside unknowns to verify that a batch meets predefined accuracy and precision criteria.
- Carryover
- Related: Interference, Validation
The transfer of residual analyte from a previous sample into a subsequent one within the analytical system, which can falsely elevate low-concentration results.