Snellen 20/40 meaning
The patient reads at 20 feet a line a standard eye reads at 40 feet, so the letter must be twice normal size; the larger denominator indicates poorer acuity.
Spherical equivalent formula
Add half the cylinder power to the sphere. A refraction of +1.00 -2.00 x 090 equals plano (0.00) spherical equivalent.
Prism diopter definition
One prism diopter displaces an image 1 cm at a distance of 1 meter, equivalent to 100 times the tangent of the deviation angle.
Vertex distance effect
Effective power changes when a lens moves from the spectacle plane to the cornea; the effect is clinically significant above roughly 4 diopters.
With-the-rule astigmatism
The steepest corneal meridian is vertical, near 90 degrees, so a minus cylinder axis is placed near 180 degrees to correct it.
Aqueous humor outflow pathway
Aqueous is made by ciliary epithelium, passes through the pupil, and drains mainly through trabecular meshwork into Schlemm canal and episcleral veins.
Corneal endothelial function
The endothelium does not regenerate and pumps fluid out of the stroma, keeping the cornea clear; failure causes stromal edema and haze.
Rods versus cones
Rods support dim-light and peripheral vision and lack color; cones concentrate in the fovea and mediate acuity and color vision.
Physiologic blind spot
The optic nerve head lacks photoreceptors, creating a scotoma about 15 degrees temporal to fixation in each eye.
Accommodation mechanism
Ciliary muscle contraction slackens the zonules, letting the lens round up and increase power for near focus; lens stiffening causes presbyopia.
Normal intraocular pressure range
Adult IOP typically falls between 10 and 21 mmHg; values outside this range warrant evaluation but do not alone diagnose glaucoma.
Atropine cycloplegic duration
Atropine is the longest-acting cycloplegic, with effects lasting up to 1 to 2 weeks, unlike short-acting tropicamide which lasts hours.
Phenylephrine action
A direct alpha-1 agonist that dilates the pupil without cycloplegia; it can elevate blood pressure in susceptible patients.
Timolol contraindications
This topical beta-blocker lowers IOP by reducing aqueous production and should be avoided in asthma and heart block.
Latanoprost mechanism
A prostaglandin analog that increases uveoscleral outflow; common effects include iris darkening and eyelash lengthening.
Punctal occlusion purpose
Applying pressure to the inner canthus for 1 to 2 minutes after a drop reduces drainage into the nose and systemic absorption.
Spacing between eye drops
Waiting about 5 minutes between different drops prevents the second drop from washing out the first and preserves each drug's effect.
Topical anesthetic limits
Agents such as proparacaine act within seconds but only for minutes; chronic use is avoided because they mask injury and impair healing.
Pinhole test interpretation
Acuity improvement through a pinhole indicates refractive blur; no improvement suggests media opacity or retinal or neural disease.
Cover test purpose
It distinguishes a manifest deviation (tropia) from a latent one (phoria); alternate cover breaks fusion to reveal the total deviation.
Amsler grid use
The patient views a grid to detect central distortion or scotoma, screening for macular disease such as degeneration or edema.
Ishihara plate purpose
These plates screen for red-green color deficiency; a normal result does not rule out acquired blue-yellow defects.
Near acuity testing distance
Near acuity is checked at about 40 cm (16 inches) with a near card, recording the smallest line read and any add power used.
Confrontation visual field
A screening test comparing the patient's peripheral field with the examiner's at about 1 meter, useful for detecting gross field loss.
Goldmann tonometry requirements
Applanation tonometry uses fluorescein and a topical anesthetic; the prism tip is cleaned and dried between patients.
Keratometry measurement
It measures corneal curvature in diopters or millimeters, informing contact lens fitting and intraocular lens power estimation.
Autorefraction role
An objective estimate of refractive error that serves as a starting point; subjective refinement yields the final prescription.
A-scan versus B-scan
A-scan biometry measures axial length for IOL calculation; B-scan provides a two-dimensional view when media are opaque.
Slit-lamp patient positioning
Chin on the chin rest, forehead against the strap, and the canthus aligned with the marker on the support for stable viewing.
Standard precautions principle
All blood and body fluids are treated as potentially infectious; gloves are worn for contact with tears, blood, or mucous membranes.
Sharps handling rule
Used needles go directly into puncture-resistant containers; recapping by hand is avoided to prevent needlestick injury.
HIPAA disclosure standard
Protected health information may be shared for treatment, payment, or operations, or with patient authorization; otherwise it stays confidential.