Medical Device Alarm Fatigue

The desensitization that occurs when clinicians are exposed to frequent or false device alarms, causing slower or missed responses to genuine alerts; managed through alarm customization, default revision, and policy-based monitoring.

Related: Alarm Signal Integration, Clinical Alarm Management Program
Clinical Alarm Management Program

A structured, multidisciplinary set of policies and practices for setting alarm limits, defining escalation, training staff, and monitoring alarm performance across a facility's monitored devices.

Related: Medical Device Alarm Fatigue, Alarm Signal Integration
Alarm Signal Integration

The routing of device alarm signals into a central station, nurse call system, or secondary notification device so the right caregiver is notified without relying on sound traveling through walls.

Related: Clinical Alarm Management Program, Medical Device Alarm Fatigue
Preventive Maintenance (PM)

Scheduled inspection, testing, and servicing performed at defined intervals to keep equipment safe and functional and to detect deterioration before it causes failure.

Related: Work Order Management, Equipment Inventory Database
Corrective Maintenance

Repair work performed after a device fails or is found defective, restoring it to safe operating condition and documenting the fault, parts, and outcome.

Related: Work Order Management, Mean Time Between Failures
Work Order Management

The process of logging, prioritizing, assigning, tracking, and closing maintenance requests so that service history and labor are recorded against each asset.

Related: Preventive Maintenance (PM), Equipment Inventory Database
Equipment Inventory Database

The authoritative record of every device owned or serviced, including identifiers, location, service history, and risk classification, used to plan and audit maintenance.

Related: Work Order Management, Device Risk-Based Inclusion Criteria
Device Risk-Based Inclusion Criteria

A scoring method that assigns equipment to maintenance schedules based on harm potential, use environment, and failure consequences rather than repairing every item on an identical interval.

Related: Equipment Inventory Database, Preventive Maintenance (PM)
Mean Time Between Failures

The average operating time between successive failures of a device or population, used to judge reliability and adjust maintenance intervals or replacement decisions.

Related: Corrective Maintenance, Device Risk-Based Inclusion Criteria
Capital Equipment Planning

The annual process of forecasting equipment needs, justifying purchases with clinical and financial data, and sequencing replacement within budget constraints.

Related: Life Cycle Cost, Total Cost of Ownership
Total Cost of Ownership

The full expense of an asset across its life, including purchase, installation, consumables, service contracts, training, utilities, and disposal, not just the sticker price.

Related: Life Cycle Cost, Capital Equipment Planning
Life Cycle Cost

The sum of acquisition, operation, maintenance, and end-of-life costs used to compare options and decide when replacement is cheaper than continued repair.

Related: Total Cost of Ownership, Capital Equipment Planning
Service Contract Management

Reviewing and negotiating vendor service agreements so that coverage, response times, exclusions, and uptime guarantees match the facility's actual risk and needs.

Related: Uptime Guarantee, In-House Service Program
Uptime Guarantee

A contractual commitment that equipment will be available for clinical use a specified percentage of time, often with remedies or credits if availability falls short.

Related: Service Contract Management, In-House Service Program
In-House Service Program

A department-run maintenance and repair capability, staffed and equipped internally, chosen instead of or alongside vendor service to control cost and response time.

Related: Service Contract Management, Competency Assessment
Health Technology Assessment

A structured evaluation of a technology's clinical effectiveness, safety, cost, and organizational impact used to inform adoption, replacement, and disinvestment decisions.

Related: Capital Equipment Planning, Technology Acquisition Review
Technology Acquisition Review

The pre-purchase review of a proposed device covering clinical need, interoperability, cybersecurity, serviceability, and regulatory status before approval.

Related: Health Technology Assessment, Cybersecurity Risk Assessment
Networked Medical Device

Any device that exchanges data over a network, creating exposure to remote access, malware, and configuration drift that must be managed like other connected assets.

Related: Cybersecurity Risk Assessment, Medical Device Inventory (Cyber)
Cybersecurity Risk Assessment

A systematic review of a device's vulnerabilities, network exposure, and potential patient harm used to prioritize patching, segmentation, and monitoring controls.

Related: Networked Medical Device, Network Segmentation
Network Segmentation

Dividing a network into isolated zones so that a compromised device or system cannot freely reach other devices, clinical systems, or business data.

Related: Cybersecurity Risk Assessment, Networked Medical Device
Interoperability

The ability of devices and information systems to exchange and correctly interpret data using agreed standards, enabling safe automated workflows and records.

Related: Health Level Seven (HL7), Interface Engine
Health Level Seven (HL7)

A family of standards governing the format and exchange of clinical and administrative messages between hospital systems such as admission, order, and results feeds.

Related: Interoperability, Interface Engine
Interface Engine

Middleware that translates, routes, and monitors messages between disparate systems, and whose failures can silently stop data flow to or from devices.

Related: Health Level Seven (HL7), Interoperability
Unique Device Identification (UDI)

A globally unique code on a device label that identifies its model and production lot, supporting recalls, inventory accuracy, and adverse event reporting.

Related: Medical Device Recall, Adverse Event Reporting
Medical Device Recall

A manufacturer or regulator action to remove or correct a device that poses a health risk, requiring identification of affected units and documented follow-up.

Related: Unique Device Identification (UDI), Field Safety Corrective Action
Field Safety Corrective Action

A manufacturer-initiated action taken outside the factory to reduce risk from a device already in use, such as software updates, relabeling, or retrieval.

Related: Medical Device Recall, Adverse Event Reporting
Adverse Event Reporting

The documented notification of device-related harm or potential harm to the manufacturer and regulator so that trends can be detected and hazards corrected.

Related: Field Safety Corrective Action, Sentinel Event
Sentinel Event

An unexpected occurrence involving death or serious harm that triggers immediate investigation and root cause analysis rather than routine handling.

Related: Root Cause Analysis, Failure Mode and Effects Analysis
Root Cause Analysis

A structured retrospective method for identifying the underlying system failures and contributing factors behind an incident so that recurrence is prevented.

Related: Failure Mode and Effects Analysis, Sentinel Event
Failure Mode and Effects Analysis

A prospective team method that lists how a process or device could fail, scores severity, likelihood, and detectability, and targets the highest-risk steps for redesign.

Related: Root Cause Analysis, Device Risk-Based Inclusion Criteria
Electrical Safety Testing

Measurement of leakage current, grounding integrity, and insulation on equipment to confirm it will not deliver harmful current to patients or staff.

Related: Applied Part, Patient Leakage Current
Applied Part

The portion of a device designed to come into physical contact with the patient, which determines the electrical safety classification and allowable leakage limits.

Related: Electrical Safety Testing, Patient Leakage Current
Patient Leakage Current

Current that could flow through a patient connected to a device under normal or single-fault conditions, kept below defined limits by design and testing.

Related: Electrical Safety Testing, Applied Part
Competency Assessment

Documented verification that a staff member can safely perform assigned tasks, typically through observation, testing, and periodic reassessment.

Related: In-House Service Program, Training Needs Analysis
Training Needs Analysis

A process of comparing required skills against current staff capability to identify gaps and design targeted education rather than generic instruction.

Related: Competency Assessment, In-Service Education
In-Service Education

Short, focused instruction delivered to clinical staff at the point of use, often after a new device is introduced or a use error is identified.

Related: Training Needs Analysis, Competency Assessment
Human Factors Engineering

Designing devices and workflows around real user capabilities and limits so that use errors are prevented or made obvious rather than blamed on the operator.

Related: Use Error, Root Cause Analysis
Use Error

A failure in the interaction between user, device, and environment that produces an unintended outcome, addressed by redesign and training rather than discipline alone.

Related: Human Factors Engineering, Failure Mode and Effects Analysis