Coagulation
A treatment step that adds a chemical such as alum to neutralize the surface charge of suspended particles so they can clump together.
Flocculation
Gentle, slow mixing that encourages small destabilized particles to collide and grow into larger floc that can settle or be filtered.
Turbidity
A measure of light scattering by suspended particles in water, reported in NTU; it indicates treatment effectiveness and possible pathogen presence.
CT value
The product of disinfectant residual concentration in mg/L and effective contact time in minutes, used to demonstrate pathogen inactivation.
Chlorine demand
The difference between the chlorine dose applied and the residual remaining after a set contact time; it reflects oxidizable material in the water.
Free chlorine residual
The portion of chlorine remaining as hypochlorous acid and hypochlorite ion after demand is satisfied; it is the active disinfecting form.
Filter backwash
A reverse-flow cleaning process that lifts and expands filter media to release trapped particles, restoring head loss and effluent quality.
NTU
Nephelometric turbidity unit, the standard unit for turbidity measured by light scatter; lower values indicate clearer, better-filtered water.
Disinfectant residual
The measurable concentration of disinfectant remaining in treated water; it protects against contamination as water travels through the system.
Minimum pressure
The lowest allowable distribution pressure, often about 20 psi, maintained to prevent backflow and contamination intrusion into mains.
Water age
The average time water spends in the distribution system; high age depletes disinfectant and can increase by-product formation.
Unidirectional flushing
A technique that opens hydrants in sequence to create high-velocity flow in one direction, scouring sediment from mains.
Air gap
A physical separation between a potable water outlet and a potential contaminant source; it is the most reliable backflow prevention method.
Reduced-pressure zone assembly
A testable backflow preventer with two check valves and a relief valve that discharges if pressure reverses, protecting against cross-connections.
Water hammer
A pressure surge caused by sudden changes in flow velocity, such as rapid valve closure, which can damage pipes and fittings.
Dead-end main
A pipe branch with no looped connection at its far end; water stagnates there, so flushing and residual monitoring are especially important.
Leak detection
Finding uncontrolled water loss using methods such as metered night flow, acoustic listening devices, and step testing of zones.
Chemical feed calibration
Verifying that a feed pump delivers the intended dose by measuring the volume pumped over a known time and comparing it to flow.
Daily operating log
A record of doses, residuals, pressures, flows, and maintenance events that provides the primary evidence of compliance and system performance.
Sample holding time
The maximum allowed interval between collecting a sample and analyzing it; exceeding it can invalidate results and require resampling.
Emergency response plan
A written document describing actions for loss of power, pressure, or source quality, including notification and alternate supply procedures.
Boil water notice
A public advisory issued when water may be contaminated, instructing customers to boil water vigorously before drinking, cooking, or brushing teeth.
Operator certification
State-issued credential confirming an operator has passed required exams and maintains continuing education to run a public water system.
Spare parts inventory
A stocked supply of critical items such as pump diaphragms, reagents, and seals so treatment can continue during equipment failures.
Safe Drinking Water Act
The federal law authorizing EPA to set drinking water standards; states usually enforce them through primacy programs.
Maximum contaminant level
The highest allowable concentration of a regulated contaminant in delivered water, set to protect public health.
Secondary standard
A non-enforceable EPA guideline for aesthetic qualities such as color, odor, taste, and corrosivity rather than health effects.
Total coliform rule
A regulation requiring routine coliform sampling; a positive result triggers repeat testing and assessment for potential contamination.
Lead action level
The 90th-percentile tap sample concentration of 0.015 mg/L that triggers corrosion control and public education requirements.
Consumer Confidence Report
An annual water quality report delivered to customers by July 1 that describes source water, detected contaminants, and health information.
Public notification
Required communication to customers about violations; acute risks require notice within 24 hours, while most others allow up to 30 days.
TTHM MCL
The maximum contaminant level of 0.080 mg/L for total trihalomethanes, a group of disinfection by-products, evaluated as a running annual average.