ABC Wastewater Collection Class IV study materials
ABC Wastewater Collection Class IV study resources

ABC Wastewater Collection Class IV flashcards

ABC Wastewater Collection Class IV · Build recall with a focused review session.

36 cards. Read the term and the definition here. The deck at the top of this page is optional.

Minimum self-cleansing velocity
About 2 ft/s in a gravity sanitary sewer keeps solids moving and limits deposition; lower velocities allow grit and grease to settle and cause blockages.
Manning's equation
Q = (1.486/n) A R^(2/3) S^(1/2) predicts gravity pipe flow, where n is roughness, A is cross-sectional area, R is hydraulic radius, and S is slope.
Hydrogen sulfide corrosion
H2S generated in pressurized or slow-flowing sewage is oxidized to sulfuric acid on concrete above the waterline, corroding pipe crowns and manholes.
Sanitary sewer overflow reporting
SSOs must be reported to the state agency within the permit's timeframe, with public notice when discharge reaches waters of the state, and a follow-up written report.
Drop manhole
A manhole with an outside or inside drop pipe that carries a high-elevation incoming sewer down the wall, reducing turbulence, scour, and H2S release.
Inverted siphon
A pipe that carries sewage under an obstruction such as a stream; it flows full under pressure and needs flushing and bypass provisions for maintenance.
Force main air valve
An air release and vacuum relief valve on a force main prevents surge, column separation, and air binding by admitting or releasing air at high points.
Manhole spacing
Manholes are placed about 300–500 ft apart on straight runs and at changes in grade, alignment, or pipe size to allow inspection and cleaning access.
Affinity laws
For a centrifugal pump, flow varies with speed, head with speed squared, and power with speed cubed, so small speed changes greatly affect power draw.
Total dynamic head
The sum of static lift, friction losses in suction and discharge piping, and velocity head that a pump must overcome to move a given flow.
Best efficiency point
The flow and head at which a pump operates most efficiently; running far from it causes recirculation, cavitation, vibration, or motor overload.
Wet well cycling limit
Wet well operating volume is sized so pump starts per hour do not exceed the motor manufacturer's limit, preventing overheating and check valve wear.
Permit-required confined space
A space with a hazardous atmosphere, engulfment potential, trapping configuration, or other serious hazard that requires a written entry permit and controls.
Atmospheric testing order
Test oxygen first, then flammable gas, then toxic gases; entry is barred below 19.5% O2, at 10% LEL or above, or at the permit's H2S limit.
Confined space attendant
A trained person stationed outside the space who maintains communication, monitors conditions, and summons rescue without entering the space.
Confined space rescue
Rescue must use trained personnel with supplied-air respiratory protection; untrained would-be rescuers account for many confined space fatalities.
Infiltration versus inflow
Infiltration is groundwater entering through pipe and joint defects; inflow is direct stormwater entering through manholes, roof drains, and illegal connections.
Smoke testing
Blowing non-toxic smoke into a sewer reveals inflow sources and illegal connections where smoke escapes from manholes, drains, or service connections.
Rainfall-dependent infiltration
The portion of wet-weather flow that responds to rainfall, quantified by comparing dry-weather and storm-period flow monitoring data.
CIPP lining
Cured-in-place pipe lining installs a resin-impregnated liner inside an existing pipe and cures it in place to seal defects and restore structure.
Peaking factor
A multiplier applied to average dry-weather flow to estimate peak flow for sizing pipes, pumps, and capacity analysis.
Area-velocity flow meter
A meter that measures flow depth and velocity in a pipe and computes flow as Q = A × V, used for capacity and I/I monitoring.
Surcharge
Condition where flow exceeds downstream capacity and the hydraulic grade line rises above the pipe crown, risking backups and overflows.
Partially full pipe flow
Maximum velocity occurs near 0.8 depth ratio and maximum flow near 0.94 depth ratio; full-flow Manning's equation overstates capacity near full.
PACP defect grading
CCTV defect codes grade severity from 1 to 5; grade 4 and 5 structural or operational defects drive rehabilitation, while lower grades may be monitored.
CCTV inspection
A camera survey of sewer interiors that records structural and maintenance defects, infiltration, and root intrusion for condition assessment and rehabilitation planning.
Dye testing
Introducing dye into a fixture or storm drain to confirm whether it connects to the sanitary sewer, verifying cross-connections and illegal connections.
Risk-based inspection
Inspection frequency set by weighing pipe age, material, soil, flow, and failure history rather than fixed intervals.
NPDES permit
A Clean Water Act permit that regulates discharges to waters of the state and sets reporting, monitoring, and notification requirements for SSOs and bypasses.
CMOM program
A capacity, management, operations, and maintenance program that documents how a collection system is operated, maintained, and kept in compliance.
OSHA confined space standard
29 CFR 1910.146 sets permit-required confined space entry requirements, including testing, ventilation, attendant, and rescue provisions.
Asset management record
Inventory, condition, work order history, and remaining useful life data used to prioritize maintenance and capital spending on collection system assets.
CMMS
A computerized maintenance management system that tracks work orders, labor, parts, and failure history to support preventive and corrective maintenance decisions.
SSO rate KPI
A key performance indicator counting sanitary sewer overflows per 100 miles of pipe, used to benchmark collection system performance.
Emergency response plan
A written plan covering SSOs, pump station failures, power outages, and hazardous releases, with call-out lists, notifications, and incident command roles.
Operator certification