ABOI/ID flashcards
ABOI/ID · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Peri-implant mucositis definition
- Bleeding and/or suppuration on gentle probing around an implant with no progressive bone loss beyond initial crestal remodeling. It is reversible with plaque control and debridement.
- Peri-implantitis definition
- Bleeding and/or suppuration on probing plus progressive bone loss beyond initial remodeling, often ≥2 mm or ≥3 threads from the implant shoulder. Requires active therapy.
- Probing depth limitation
- Probing depth alone does not diagnose peri-implant disease because tissue biotype and implant position affect readings. Bleeding, suppuration, and bone change are more reliable indicators.
- Radiographic baseline timing
- The reference radiograph for long-term comparison is taken at prosthesis delivery, not at implant placement, because crestal remodeling occurs during healing and loading.
- Keratinized mucosa significance
- Keratinized mucosa width under 2 mm is associated with more plaque accumulation, bleeding, and recession. It is a risk indicator rather than a diagnosis.
- CBCT indications
- CBCT is reserved for suspected vital structure proximity, ridge deficiency, pathology, or unexplained symptoms. It is not a routine screening tool for every implant.
- Implant risk factors
- Smoking, poorly controlled diabetes, history of periodontitis, parafunction, and poor oral hygiene increase failure and peri-implant disease risk and must be assessed preoperatively.
- Implant failure signs
- Mobility, rapidly progressive bone loss, suppuration unresponsive to therapy, and pain suggest implant failure or infection requiring urgent evaluation and possible removal.
- Primary stability determinants
- Primary stability depends on bone density and implant geometry. ISQ ≥70 or insertion torque ≥35 Ncm generally supports immediate or early loading protocols.
- Loading timeline categories
- Conventional loading occurs at 3 months mandible and 4-6 months maxilla; early loading 1 week to 2 months; immediate loading within 1 week of placement.
- Inter-implant spacing rule
- A minimum of 2 mm between adjacent implants and 1.5-2 mm between implant and adjacent tooth helps preserve crestal bone and support the interproximal papilla.
- Sinus lift approach selection
- Crestal osteotome approach suits limited residual height with adequate density; lateral window approach is used for severe pneumatization or residual height under 4-5 mm.
- Guided bone regeneration requirements
- GBR requires a barrier membrane plus graft, passive primary closure, and tension-free flap advancement. Membrane exposure risks graft contamination and loss.
- Thermal injury prevention
- Copious irrigation, sharp sequential drills, controlled speed, and intermittent drilling keep bone temperature below approximately 47°C to avoid necrosis and failure.
- Inferior alveolar nerve margin
- A 2 mm safety margin from the inferior alveolar canal is standard. CBCT measurement and surgical guides are used when proximity is close.
- Immediate placement contraindications
- Active infection, insufficient apical bone, and inability to achieve primary stability are contraindications to immediate implant placement after extraction.
- Screw versus cement retention
- Screw-retained restorations are preferred when access and angulation permit. Cement-retained are used for esthetics or unfavorable angulation but require meticulous cement removal.
- Provisional occlusion rule
- The provisional restoration should be out of occlusion in maximum intercuspation and excursive movements to protect the developing implant interface.
- Impression timing
- Final impressions are taken after confirming osseointegration, absence of symptoms, and soft tissue stability. Timing depends on healing and tissue maturation.
- Emergence profile design
- Custom abutments and emergence profiles should support peri-implant soft tissue and create cleansable contours that allow effective hygiene access.
- Implant occlusal scheme
- Use light centric contacts, eliminate working and non-working interferences, and avoid cantilevers that concentrate load on the implant and prosthesis.
- Abutment screw torque
- Abutment screws are typically tightened to 20-35 Ncm per manufacturer instructions and retightened after initial seating using a calibrated torque wrench.
- Passive fit verification
- An ill-fitting framework creates stress, screw loosening, and marginal bone loss. Verify fit with a single-screw test or radiograph before final delivery.
- Retrievability principle
- Implant-supported fixed prostheses should be retrievable where possible. Design screw access and document torque values for future maintenance and repair.
- Maintenance interval selection
- Recall every 3 months for high-risk patients such as smokers, periodontitis history, or poor hygiene; every 6 months for low-risk patients, adjusted by findings.
- Probing force around implants
- Use light force of approximately 0.25 N with a plastic or metal probe. Record probing depths, bleeding, and suppuration at every maintenance visit.
- Mucositis versus peri-implantitis therapy
- Peri-implant mucositis is reversible with nonsurgical debridement and improved hygiene. Peri-implantitis requires surgical or combined therapy and may not resolve.
- Recall radiographic interval
- Radiographs are taken at baseline, then every 1-2 years or when clinical changes appear. Compare to the delivery baseline for bone-level trends.
- Peri-implant screening at recall
- Screen for peri-implant disease at every recall because untreated mucositis can progress to peri-implantitis with irreversible bone loss.
- Occlusal re-evaluation at recall
- Recall visits should assess wear, screw loosening, and parafunctional overload. Adjust occlusal contacts as needed to protect the implant restoration.
- Systemic risk reassessment
- Smoking, diabetes, and medications causing xerostomia should be reassessed and managed at recall to reduce long-term failure and peri-implant disease risk.
- Implant documentation
- Record implant brand, lot number, torque values, and restoration type. This information is critical for managing future complications and maintenance.