ABOI/ID study materials
ABOI/ID study resources

ABOI/ID key terms

ABOI/ID · Get comfortable with the vocabulary.

Osseointegration

Direct structural and functional connection between living bone and the surface of a load-bearing implant without intervening soft tissue. It is assessed clinically by absence of mobility and radiographically by maintained bone-to-implant contact.

Related: Primary Stability, Implant Stability Quotient
Primary Stability

Mechanical grip of an implant in bone immediately after placement, derived from friction and bone compression. It determines whether an implant can be loaded early and is influenced by bone density, drill protocol, and implant geometry.

Related: Osseointegration, Insertion Torque, Underdrilling
Secondary Stability

Stability that develops after placement through new bone formation and remodeling at the implant surface. It increases as primary mechanical stability declines, and the two together define the stability dip.

Related: Osseointegration, Implant Stability Quotient
Insertion Torque

Rotational force in newton-centimeters required to seat an implant. Values around 30 to 50 Ncm are commonly used as a threshold supporting immediate or early loading decisions, though no single value guarantees success.

Related: Primary Stability, Immediate Loading
Implant Stability Quotient

A dimensionless reading, typically 1 to 100, obtained by resonance frequency analysis of an implant's response to vibration. Higher values suggest greater stability, and serial readings help track changes over healing.

Related: Secondary Stability, Insertion Torque
Underdrilling

Preparing an osteotomy with a final drill narrower than the implant, increasing bone compression and torque. It is used to raise primary stability in soft bone but risks overheating and fracture if overdone.

Related: Primary Stability, Insertion Torque
Crestal Bone Loss

Radiographic reduction in marginal bone height around an implant, measured from the implant shoulder or first thread. Early remodeling of roughly 1 to 2 mm is common; progressive loss suggests peri-implant disease or biomechanical overload.

Related: Peri-Implantitis, Biological Width
Peri-Implant Mucositis

Reversible inflammation confined to the soft tissues around an implant, with bleeding on probing and no progressive bone loss. It is treated by debridement and improved plaque control, and it may progress if untreated.

Related: Peri-Implantitis, Bleeding on Probing
Peri-Implantitis

Inflammatory condition of peri-implant tissues characterized by bleeding on probing and progressive loss of supporting bone beyond expected remodeling. Management includes nonsurgical debridement, surgical access, and sometimes implant removal.

Related: Peri-Implant Mucositis, Crestal Bone Loss
Biological Width

Soft tissue seal comprising junctional epithelium and connective tissue attachment that forms around an implant or abutment. Its dimensions influence where the restorative margin should sit relative to bone.

Related: Platform Switching, Crestal Bone Loss
Platform Switching

Use of an abutment narrower than the implant platform, shifting the implant-abutment junction medially. It is associated with less crestal bone remodeling and better preservation of marginal bone.

Related: Biological Width, Crestal Bone Loss
Bone Density Classification

Grouping of jaw bone quality by trabecular and cortical character, commonly using the Lekholm and Zarb or Misch scales. It guides drill sequence, implant choice, and healing time expectations.

Related: Underdrilling, Cone Beam Computed Tomography
Cone Beam Computed Tomography

Three-dimensional radiographic imaging used to assess bone volume, ridge shape, and proximity to vital structures such as the inferior alveolar nerve and maxillary sinus. It supports surgical planning and guide fabrication.

Related: Surgical Guide, Residual Ridge Mapping
Residual Ridge Mapping

Clinical and radiographic assessment of the width, height, and contour of an edentulous ridge. It determines whether implant placement is feasible and whether simultaneous or staged grafting is needed.

Related: Cone Beam Computed Tomography, Guided Bone Regeneration
Surgical Guide

A stent, often fabricated from planning software, that transfers planned implant position, angulation, and depth to the surgical site. It may be tooth-supported, mucosa-supported, or bone-supported.

Related: Cone Beam Computed Tomography, Flapless Placement
Flapless Placement

Implant surgery performed through a small punch or tissue-level incision without raising a mucoperiosteal flap. It reduces morbidity but limits visibility and is best suited to adequate bone volume confirmed by imaging.

Related: Surgical Guide, Guided Bone Regeneration
Guided Bone Regeneration

Technique using a barrier membrane, with or without particulate graft, to exclude soft tissue and allow bone to fill a defect. It is used for ridge augmentation and for defects around implants.

Related: Residual Ridge Mapping, Sinus Floor Elevation
Sinus Floor Elevation

Procedure that lifts the maxillary sinus membrane to create bone height for implants in the posterior maxilla. It may be done through a lateral window or a crestal approach, with or without grafting.

Related: Guided Bone Regeneration, Residual Ridge Mapping
Immediate Implant Placement

Insertion of an implant into a fresh extraction socket at the time of tooth removal. It can reduce treatment time but requires acceptable socket walls, absence of acute infection, and stable primary fixation.

Related: Immediate Loading, Primary Stability
Immediate Loading

Placement of a functioning restoration on an implant within roughly one week of surgery, so the implant bears occlusal load during early healing. It demands high primary stability and careful occlusal control.

Related: Insertion Torque, Immediate Implant Placement
Implant Abutment Junction

Interface where the abutment meets the implant platform. Its design and fit affect microgap size, bacterial leakage, and stress transfer to crestal bone.

Related: Platform Switching, Abutment
Abutment

Component that connects the implant to the prosthesis, providing retention and support. Abutments may be stock, custom, or multi-unit, and their selection depends on angulation, tissue depth, and restoration type.

Related: Implant Abutment Junction, Prosthetic Screw Loosening
Multi-Unit Abutment

Abutment designed to support splinted prostheses, often with a conical connection and screw retention. It simplifies retrieval and is commonly used in full-arch fixed restorations.

Related: Abutment, Passive Fit
Passive Fit

Condition in which a framework seats on its abutments without induced strain. Poor fit concentrates stress, risking screw loosening, fracture, and bone loss, and is checked clinically and in the laboratory.

Related: Prosthetic Screw Loosening, Multi-Unit Abutment
Prosthetic Screw Loosening

Loss of preload in the screw retaining an implant restoration, allowing the prosthesis to loosen. Causes include inadequate torque, misfit, parafunction, and settling of interfaces.

Related: Passive Fit, Preload
Preload

Tensile force stored in a tightened screw that clamps components together. It depends on applied torque, thread friction, and material, and it must exceed functional separating forces to prevent loosening.

Related: Prosthetic Screw Loosening, Abutment
Cement-Retained Restoration

Implant prosthesis fixed with dental cement rather than a screw. It offers esthetic and angulation flexibility but carries risk of retained cement and peri-implant inflammation if excess is not removed.

Related: Screw-Retained Restoration, Peri-Implantitis
Screw-Retained Restoration

Implant prosthesis secured with a screw through the implant or abutment. It is retrievable and avoids cement, though it requires access-hole management and favorable implant angulation.

Related: Cement-Retained Restoration, Preload
Emergence Profile

Contour of the restoration and soft tissue as they exit the gingival or peri-implant margin. It influences esthetics, cleansability, and soft tissue health, and may be shaped with provisional restorations.

Related: Provisional Restoration, Biological Width
Provisional Restoration

Temporary prosthesis used during healing or before final fabrication. It can guide soft tissue form, provide function and esthetics, and test occlusal and phonetic outcomes.

Related: Emergence Profile, Immediate Loading
Occlusal Overload

Forces on an implant exceeding its or the bone's adaptive capacity, often from parafunction, cantilevers, or premature contacts. It may contribute to bone loss, screw loosening, or component fracture.

Related: Prosthetic Screw Loosening, Crestal Bone Loss
Occlusal Scheme

Arrangement of contacts and guidance designed for an implant-supported prosthesis. Mutually protected or group function patterns are chosen to direct forces along the implant axis and reduce lateral stress.

Related: Occlusal Overload, Cantilever
Cantilever

Extension of a prosthesis beyond its most distal support. Longer cantilevers magnify force and bending moments on implants and are generally limited, especially in the posterior maxilla.

Related: Occlusal Overload, Occlusal Scheme
Bleeding on Probing

Bleeding elicited when a periodontal probe is gently passed along the peri-implant sulcus. It is a key sign of inflammation and, with increasing probing depth, raises suspicion of peri-implant disease.

Related: Peri-Implant Mucositis, Peri-Implantitis
Probing Depth

Distance from the mucosal margin to the base of the peri-implant sulcus or pocket. Serial measurements detect attachment loss, and a trend of increasing depth is more informative than a single reading.

Related: Bleeding on Probing, Peri-Implantitis
Supportive Peri-Implant Care

Structured long-term maintenance including reassessment of probing depths, bleeding, occlusion, and radiographs at intervals tailored to risk. It aims to prevent disease onset and detect recurrence early.

Related: Peri-Implant Mucositis, Probing Depth
Risk Assessment

Systematic evaluation of patient factors such as smoking, diabetes, periodontitis history, bone quantity, and parafunction before treatment. It informs prognosis, treatment planning, and recall frequency.

Related: Supportive Peri-Implant Care, Residual Ridge Mapping
Implant Fixture Fracture

Breakage of the implant body, most often from fatigue under overload, misfit, or narrow-diameter implants in posterior sites. It usually requires removal and replacement.

Related: Occlusal Overload, Passive Fit