AGM Bank: Alternator Sense Lead and Charger Temperature Compensation

ABYC Marine Electrical · Put your knowledge to work in context.

All case studies

AGM Bank: Alternator Sense Lead and Charger Temperature Compensation

The house bank is four 100 Ah AGM batteries (400 Ah total). A 60 A alternator with an external regulator charges the bank through a 6 AWG cable with a 15 ft one-way run. The regulator's voltage-sense lead is connected at the alternator output, not at the battery. At 60 A output the alternator terminal reads 14.6 V and the battery post reads 13.9 V. The AGM maker specifies a maximum charge rate of 0.2C, absorption at 14.4 V, float at 13.5 V, and temperature compensation of -30 mV/°C above 25 °C. Engine-room temperature is 45 °C. A 40 A shore charger is set to 14.4/13.5 V and has no battery temperature sensor. The owner says the bank never gets above about 70% state of charge after a 5-hour motor and that the shore charger takes 14 hours.

1. Calculate the voltage drop in the alternator charge cable and explain the charging symptom. What is the first correction?

Read the worked answer

Vdrop = 2KIL/CM = 2 x 10.7 x 60 x 15 / 26,240 = 19,260 / 26,240 = 0.73 V. That matches the observed 0.7 V difference, so the cable is the cause. The regulator is sensing at the alternator, so it holds 14.6 V there; the battery only receives 13.9 V. For an AGM bank needing 14.4 V absorption, 13.9 V is below the absorption setpoint, so the bank stays in bulk or partial charge and never reaches full. Move the voltage-sense lead to the battery positive post (with a small fuse), or use a remote-sense regulator, and then confirm the battery sees 14.4 V at 25 °C. Do not simply raise the regulator setpoint; that would overcharge once the drop is fixed. Also check the negative return and all terminations.

2. Evaluate whether the 40 A shore charger is adequate for the 400 Ah bank, including the effect of 15 A of DC loads and the missing temperature sensor.

Read the worked answer

40 A is 0.10C for a 400 Ah bank, below the 0.20C maximum, so it is not dangerous. But with 15 A of DC loads, net charge is 25 A, or 0.0625C. Replacing 120 Ah (50% to 80%) takes about 4.8 hours at 25 A before the absorption tail, so 14 hours is plausible if the bank started low. A 60 A charger would give about 45 A net and is still only 0.15C; it would shorten recharge time. Temperature is the bigger issue: at 45 °C the compensation is (45 - 25) x -30 mV = -0.6 V, so absorption should be about 13.8 V and float about 12.9 V. With no sensor and fixed 14.4/13.5 V, the charger overcharges the AGM bank at 45 °C. Add a battery temperature sensor or reduce the setpoints and verify against the battery maker's data.

3. Is the 60 A alternator itself inadequate? Explain what measurements and decisions you would make before recommending a larger alternator.

Read the worked answer

The 60 A alternator is 0.15C, within the 0.20C maximum, so it is adequate in principle for a 400 Ah bank; it is not the first thing to replace. In a 45 °C engine room, alternator output may derate, and the 60 A rating may not be available continuously. First correct the sense lead and add battery temperature compensation; then measure actual charge current and battery voltage at the battery posts. If the owner wants faster recharge with heavy DC loads, a larger alternator or a second charge source may be justified, but the charge cable and fusing must be sized for the new output. Do not assume the alternator's hot rating equals its cold rating.