DC Electrical Theory, Circuits, and Ohm's Law

  • Ohm's law: E = I × R; rearranged, I = E/R and R = E/I, with E in volts, I in amperes, and R in ohms.

  • DC power: P = E × I; equivalent forms are P = I²R and P = E²/R, with P in watts.

  • Series circuit: one common current; R_total = R1 + R2 + ...; source voltage equals the sum of individual voltage drops.

  • Parallel circuit: one common voltage; branch currents add; 1/R_total = 1/R1 + 1/R2 + ... .

  • Kirchhoff's laws: current entering a node equals current leaving; voltage drops around a closed loop sum to zero.

  • Two-wire DC voltage drop: V_drop = 2 × L × I × R_conductor, where L is one-way length; total drop should not exceed 10% of nominal, or 3% for critical loads.

  • Ampacity varies with conductor gauge, insulation temperature rating, and bundling; marine cable commonly has 105°C insulation.

  • A 12 V battery can deliver hundreds of amperes into a low-resistance short; conductor and overcurrent protection must withstand available fault current.

  • The ungrounded (positive) DC conductor is switched and overcurrent-protected; the negative return is the DC ground reference.

Quick reference

Batteries, Battery Charging Systems, and Battery Installation

  • Rested flooded lead-acid state of charge at 77°F: 12.65 V = 100%, 12.45 V = 75%, 12.24 V = 50%, 12.06 V = 25%, about 11.9 V = 0%.

  • Specific gravity: about 1.265 fully charged and 1.120 discharged; correct hydrometer reading by adding 0.004 per 10°F above 80°F and subtracting below.

  • Three-stage charging: bulk constant current, absorption constant voltage (about 14.4 V flooded at 77°F), then float (about 13.2–13.5 V).

  • Temperature compensation for a 12 V lead-acid battery is roughly −0.03 V per °C; charging voltage must fall as battery temperature rises.

  • Capacity ratings: amp-hours at the 20-hour rate, reserve capacity in minutes at 25 A, and cold cranking amps at 0°F; Peukert effect reduces usable capacity at high discharge rates.

  • Battery installation: secure against movement, cover terminals, exclude ignition sources, ventilate flooded batteries for hydrogen, and contain spilled electrolyte.

  • Battery switch positions ON/OFF/1/BOTH/2; do not turn the switch to OFF while the engine is running because the alternator can suffer a load-dump voltage spike.

  • LiFePO4 batteries require a battery management system, no equalization, and no charging below 0°C; ABYC E-13 addresses lithium-ion installation.

Quick reference

DC Distribution, Conductors, Overcurrent Protection, and Wiring Methods

  • ABYC E-11 overcurrent protection: within 7 in (178 mm) of the power source, or within 40 in (1.0 m) when the conductor is enclosed in a sheath or raceway.

  • Overcurrent device rating must not exceed the conductor ampacity after derating for temperature and bundling; the device protects the wire, not the appliance.

  • DC circuit breakers and fuses must be DC-rated; AC-rated breakers may not safely interrupt DC arc faults.

  • ABYC color code: DC positive red, DC negative yellow, AC ungrounded hot black, AC neutral white, AC safety ground green.

  • Marine conductors are stranded tinned copper with 105°C insulation, crimped solderless terminals, and adhesive heat-shrink; wire nuts and solid wire are not acceptable.

  • Support conductors at intervals not exceeding 18 in (450 mm); protect them from chafe, sharp edges, heat, and fuel-system contact.

  • Use 3% maximum voltage drop for navigation lights, electronics, and critical circuits; 10% is the general maximum for other DC circuits.

  • DC grounding: the negative system bonds to the engine block or a common grounding bus, which also connects to the AC safety ground at one point.

  • Panel distribution: main breaker feeds branch breakers through bus bars; label all circuits and keep AC and DC panels physically separate.

Quick reference

AC Shore Power Systems, Onboard AC Generation, and Ground Fault Protection

  • Common shore power: 120 V 30 A with a NEMA TT-30 plug, or 125/250 V 50 A with a NEMA SS2-50 plug; inlet, cord, and main breaker must match.

  • Shore power neutral is bonded to ground at the shore source only; bonding neutral to ground on board creates a parallel ground path and can energize metal parts.

  • Reversed polarity means hot and neutral are swapped; a polarity tester or ELCI must detect it before the boat is connected.

  • ELCI: equipment leakage circuit interrupter, about 30 mA trip, installed at or within 10 ft of the shore power inlet to protect the whole boat.

  • GFCI: ground fault circuit interrupter, about 5 mA trip, required for galley, head, weather-deck, and other wet-location receptacles.

  • Galvanic isolator: in series with the shore safety ground, blocks low-voltage galvanic DC current while passing AC fault current.

  • Isolation transformer: breaks the shore ground galvanic path and provides a separately derived AC source; its secondary neutral is bonded to ground at the transformer.

  • Generator or inverter as a separately derived source: neutral bonded to ground at the source, and the transfer switch must switch the neutral.

  • Never parallel shore power and generator/inverter outputs; use a transfer switch or interlocked breakers.

Quick reference

Bonding, Grounding, Cathodic Protection Interfaces, and Lightning Protection

  • Bonding connects all underwater metal fittings to a common bus and to anodes so they sit at the same electrical potential.

  • AC safety ground, DC negative, and bonding system meet at one common ground point, usually the engine block or a dedicated grounding bus.

  • Galvanic corrosion: dissimilar metals in an electrolyte form a cell; the less noble metal becomes the anode and corrodes.

  • Anode selection: zinc or aluminum for salt water, magnesium for fresh water; replace when about 50% consumed.

  • Cathodic protection requires a continuous electrical path from anode to protected metal; a reference electrode verifies protection potential.

  • Stray current corrosion: external DC current leaves submerged metal into water; clamp-meter testing and isolation of shore ground help locate it.

  • Lightning protection: air terminal at the highest point, down conductor of at least 8 AWG copper, and a ground plate bonded to major metal fittings.

  • The lightning ground system is separate from the AC safety ground; bonding large metal objects reduces side-flash hazards.

Quick reference

Motors, Generators, Inverters, Panels, and Electrical Troubleshooting

  • Motor branch circuit: short-circuit protection sized to the conductor and separate overload protection sized to the motor nameplate current.

  • Generator ratings: continuous kW is for indefinite operation; standby or intermittent ratings apply only for short periods.

  • Inverter output: pure sine wave runs sensitive electronics; modified sine wave is cheaper but can cause motor heating and interference.

  • Inverter/charger installation: DC input fused at the battery, AC input protected, case grounded, and neutral-ground bonding correct for the source mode.

  • Panel layout: main breaker, branch breakers, bus bars, and clear labels; DC breakers must be DC-rated and AC panels separated from DC panels.

  • Voltage drop test: measure across a connection or conductor under load; excessive drop means corrosion, loose terminals, or undersized wire.

  • Insulation resistance test: a megohmmeter checks an isolated conductor to ground; low readings indicate moisture, damage, or insulation breakdown.

  • Troubleshooting sequence: verify battery voltage, check fuses/breakers, test continuity with power off, then measure voltage and current under load.