Ohm's law formula
Ohm's law states that voltage equals current multiplied by resistance (E = I × R); it also rearranges to I = E/R and R = E/I for DC circuit calculations.
DC power formula
Electrical power in a DC circuit equals voltage times current (P = E × I); it can also be calculated as P = I²R or P = E²/R when current or voltage is unknown.
Parallel circuit rule
In a parallel circuit the voltage across each branch is the same, branch currents add to total current, and total resistance is found from 1/R_total = 1/R1 + 1/R2 + ... .
Voltage drop limit
ABYC E-11 recommends total DC voltage drop no greater than 10 percent of nominal system voltage, and no more than 3 percent for navigation lights, electronics, and other critical loads.
Series circuit rule
In a series circuit the same current flows through every component, voltages across components add to source voltage, and total resistance equals the sum of individual resistances.
Flooded battery 50 percent
A rested 12-volt flooded lead-acid battery at 50 percent state of charge typically reads about 12.24 volts at 77°F (25°C); specific gravity is roughly 1.190.
Three-stage charging
Lead-acid three-stage charging uses bulk constant-current, absorption constant-voltage, and float constant-voltage stages; absorption voltage is about 14.4 volts for flooded batteries at 77°F.
Battery capacity rating
Amp-hour capacity is measured at the 20-hour discharge rate; reserve capacity is minutes at 25 amps, and cold cranking amps is the current a battery delivers at 0°F for 30 seconds.
Battery switch BOTH
The BOTH position parallels two battery banks for combined loads or charging; it can drain both banks and should not be used to combine a deeply discharged bank with a charged one.
LiFePO4 charging limit
Lithium iron phosphate batteries must not be charged below 0°C (32°F); charging at freezing can cause lithium plating and permanent damage, so a battery management system blocks charge current.
Battery installation rules
ABYC E-10 requires batteries to be secured against movement, terminals protected from short circuits, ignition sources excluded, and flooded batteries ventilated to remove hydrogen gas.
Overcurrent protection distance
ABYC E-11 requires overcurrent protection within 7 inches (178 mm) of the power source; 40 inches (1.0 m) is allowed when the conductor is enclosed in a sheath or raceway.
DC negative color code
ABYC E-11 recommends yellow insulation for the DC negative conductor and red for the DC positive, avoiding black because black identifies the AC ungrounded hot conductor.
Breaker rating rule
A fuse or circuit breaker must be rated to protect the conductor's ampacity after temperature and bundling derating; its rating must not exceed the conductor ampacity, regardless of load current.
Marine conductor type
Marine DC wiring uses stranded tinned-copper conductors with 105°C insulation, crimped solderless terminals, and adhesive heat-shrink; solid wire and wire nuts are not acceptable.
Conductor support interval
ABYC E-11 requires conductors to be supported at intervals not exceeding 18 inches (450 mm) and protected from chafe, sharp edges, and heat sources.
DC grounding connection
The DC negative system is bonded to the engine block or a common grounding bus, and that point is connected to the AC safety ground so the system has one common ground reference.
Shore power neutral bond
On shore power the neutral is bonded to ground at the shore source, not on board; bonding neutral and ground on board creates a parallel ground path and defeats ground fault protection.
ELCI trip threshold
An equipment leakage circuit interrupter protects the whole shore power circuit and trips at about 30 milliamps of leakage; ABYC requires it at or near the shore power inlet.
GFCI trip threshold
A ground fault circuit interrupter trips at about 5 milliamps and is required for receptacles in galley, head, weather deck, and other wet or damp locations on boats.
Galvanic isolator function
A galvanic isolator is installed in series with the shore power safety ground; it blocks low-voltage galvanic DC current while passing AC fault current to protect underwater metals.
Generator neutral bonding
A generator or inverter operating as a separately derived AC source must have its neutral bonded to its safety ground at the source, and the transfer switch must switch the neutral.
Sacrificial anode selection
Zinc or aluminum anodes are used in salt water and magnesium anodes in fresh water; the anode must be electrically connected to the protected metal and replaced when about half consumed.
Bonding system purpose
The bonding system connects underwater metal fittings to a common bus and to anodes so they remain at the same potential, reducing galvanic corrosion and electric shock hazards.
Lightning down conductor
A lightning protection system uses an air terminal at the highest point, a down conductor of at least 8 AWG copper, and a ground plate bonded to major metal fittings.
Stray current corrosion
Stray current corrosion occurs when external DC current leaves a submerged metal fitting into the water; it is detected with a clamp meter and often traced to faulty wiring or shore power.
AC ground connection point
The AC safety ground connects to the DC grounding system and bonding system at one point, usually the engine block or a dedicated grounding bus, to avoid ground loops.
Inverter output waveform
Pure sine wave inverters produce smooth AC similar to utility power and run sensitive electronics; modified sine wave inverters are cheaper but can cause overheating and interference.
Motor overload protection
Motor branch circuits require short-circuit protection sized to the conductor and separate overload protection sized to the motor nameplate current; overload devices protect the motor from sustained overcurrent.
Voltage drop testing
A voltage drop test measures potential difference across a connection or conductor while current flows; excessive drop indicates high resistance from corrosion, loose terminals, or undersized wire.
Insulation resistance test
A megohmmeter applies a high DC voltage to an isolated conductor and measures leakage to ground; low insulation resistance indicates moisture, damage, or breakdown in the wiring.
Generator continuous rating
A marine generator's continuous rating is the power it can supply indefinitely; standby or intermittent ratings apply only for short periods and should not be used for continuous loads.