ACCA Residential HVAC Design flashcards
ACCA Residential HVAC Design · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Manual J purpose
- It calculates room-by-room heating and cooling loads from envelope, infiltration, internal, and duct gains. Equipment selection must follow this calculation rather than precede it.
- Sensible vs latent load
- Sensible load changes air temperature; latent load removes moisture. Manual J computes both separately, and equipment must satisfy each at design conditions.
- Manual S sizing rule
- Total capacity must meet or exceed total load, and sensible capacity must meet sensible load at design entering wet-bulb. Permissible oversizing is explicitly limited.
- Oversizing consequences
- Excess capacity shortens runtime, increases cycling losses, reduces latent removal, and causes temperature swings. Manual S limits oversizing for these reasons.
- Available external static
- Total external static pressure minus pressure drops of devices and coils. This remainder is apportioned across supply and return duct runs to set friction rate.
- Equivalent length in Manual D
- Straight-run length plus fitting allowances. At fixed available static, higher equivalent length lowers friction rate and requires larger ducts.
- Design wet-bulb role
- Coincident wet-bulb with design dry-bulb sets latent load and coil entering conditions. Sensible capacity is rated at a specific entering wet-bulb.
- Room airflow allocation
- Manual D assigns cfm to each room consistent with Manual J room loads, so delivered airflow matches calculated space requirements.
- ANSI/ACCA 5 QI
- The HVAC Quality Installation Specification. It defines verifiable criteria for design, installation, commissioning, and documentation of residential systems.
- Superheat charging method
- For fixed-orifice systems, charge is set by measuring superheat and matching manufacturer tables at specified indoor and outdoor conditions.
- Subcooling charging method
- For TXV systems, charge is set by measuring subcooling at the condenser liquid line and matching the manufacturer's target value.
- Target residential airflow
- Roughly 350 to 450 cfm per ton of cooling. Lower airflow risks coil icing and compressor overheating; higher airflow reduces latent removal.
- Deep vacuum target
- Evacuation to about 500 microns or below, held to confirm stability, removes moisture and non-condensables before charging the system.
- Combustion safety testing
- Draft measurement and CO testing on gas appliances. Spillage or elevated CO requires correction before the installation is accepted.
- Duct leakage testing
- Quantifies distribution losses from the duct system. Sealed and tested ducts reduce effective load and improve delivered capacity to rooms.
- Commissioning records
- Documentation of static pressure, temperature split, charge method, airflow, and combustion results. These support warranty and quality verification.
- Section 608 certification
- Clean Air Act requirement that technicians handling refrigerants be certified for the equipment class they service, including small appliances and high-pressure systems.
- R-410A pressure characteristics
- An HFC blend with zero ozone depletion but high GWP. It operates at roughly 50 to 70 percent higher pressures than R-22, requiring rated equipment.
- A2L refrigerant safety
- Mildly flammable classification. Handling requires ignition-source awareness, ventilation, adherence to charge limits, and proper labeling per applicable standards.
- Recovery cylinder limits
- Cylinders must be DOT-approved and not overfilled, typically capped near 80 percent fill. They must be labeled with refrigerant type and amount.
- Leak repair requirements
- EPA rules require repairing leaks above threshold rates for appliances of specified charge sizes, followed by verification testing to confirm the repair.
- No venting rule
- Refrigerant must never be vented to atmosphere. Recovery, recycling, or reclamation are the only permitted disposition paths under federal rules.
- Permit requirements
- New installations, changeouts, and duct alterations typically require permits and inspections. Exact scope varies by jurisdiction and must be confirmed locally.
- Load calc as submittal
- Load calculations and equipment selection documents are commonly required for permit review and for utility or rebate program qualification.
- Energy code sizing link
- Many energy codes, such as the IECC, reference Manual J, S, and D compliance as the basis for equipment sizing and duct design.
- Contract essentials
- A written agreement should define scope, equipment model numbers, warranties, payment schedule, and change-order procedures to limit disputes.
- Refrigerant recordkeeping
- Purchase and handling records support EPA compliance and may be requested during audits of refrigerant use and disposal.
- Warranty documentation
- Manufacturer coverage often depends on documented commissioning data such as charge verification, airflow, and static pressure. Missing records can void coverage.
- Change order practice
- Written change orders approved before work proceeds protect both margin and legal standing when scope or conditions differ from the original contract.
- Temperature split check
- Measured difference between return and supply air. It is a commissioning indicator of airflow and charge performance against expected values.
- Infiltration estimation
- Derived from envelope tightness, often blower-door ACH50 converted to natural ACH, plus wind and stack factors rather than fixed rules of thumb.
- HFO lower-GWP blends
- Refrigerants such as R-454B with substantially lower global warming potential than R-410A, increasingly used in new residential equipment.