- Medical device definition
- An instrument, apparatus, implement, machine, implant, reagent, software, or material intended by its manufacturer for a medical purpose such as diagnosis, prevention, monitoring, treatment, or alleviation of disease.
- In vitro diagnostic device
- A device intended to examine specimens derived from the human body to provide information about physiological or pathological states, congenital abnormalities, safety, or compatibility with potential recipients.
- Significant risk device
- An investigational device that presents a potential for serious risk to the health, safety, or welfare of a subject and therefore requires an IDE and full IRB review.
- Non-significant risk device
- An investigational device that does not pose a serious risk to subjects and is studied under abbreviated requirements, including IRB approval and informed consent without an IDE.
- 510(k) premarket notification
- A premarket submission demonstrating that a new device is substantially equivalent to a legally marketed predicate device in intended use and technological characteristics.
- Premarket approval (PMA)
- The FDA pathway for Class III devices requiring valid scientific evidence providing a reasonable assurance of safety and effectiveness before marketing.
- Primary endpoint
- The prespecified outcome that answers the primary study hypothesis and typically drives the sample size calculation and statistical analysis plan.
- Surrogate endpoint
- A laboratory measurement or biomarker used as a substitute for a clinically meaningful endpoint to predict benefit or harm, such as HbA1c for diabetes outcomes.
- Clinical investigation plan
- The document describing the rationale, objectives, design, methods, statistical considerations, monitoring, and record-keeping for a medical device clinical investigation.
- Vulnerable subjects
- Individuals whose willingness to volunteer may be unduly influenced by expectation of benefit or fear of reprisal, such as prisoners, employees, students, or cognitively impaired persons.
- Single-blind design
- A study design in which one party, usually the subject, is unaware of treatment assignment while the investigator or assessor knows the assignment.
- Double-blind design
- A study design in which both the subject and the investigator or outcome assessor are unaware of treatment assignment, reducing bias in outcome measurement.
- Open-label investigation
- A study in which all parties know the treatment assignment, often used when device characteristics or procedural requirements make masking impractical.
- ISO 14155 scope
- The international standard specifying good clinical practice requirements for designing, conducting, recording, and reporting clinical investigations of medical devices in human subjects.
- ICH E6 alignment
- ICH E6 provides good clinical practice principles for trials; ISO 14155:2026 aligns device investigation terminology and expectations with these principles while addressing device-specific requirements.
- Informed consent timing
- Consent must be obtained and documented before any investigation-specific procedure is performed, after the subject receives adequate information about risks, benefits, and alternatives.
- Ethics committee approval
- Approval by an independent ethics committee or IRB must be obtained before the investigation begins and before implementing substantive amendments to the clinical investigation plan.
- Sponsor responsibilities
- The sponsor ensures a quality management system, develops the CIP, selects investigators, monitors the investigation, manages safety reporting and device accountability, and may delegate duties in writing.
- Investigator responsibilities
- The investigator conducts the investigation per the CIP, obtains consent, records source data, reports adverse events, ensures device accountability, and retains essential records.
- Serious adverse event
- An adverse event that results in death, is life-threatening, requires hospitalization or prolongation of hospitalization, causes disability, or is a congenital anomaly.
- Serious adverse device effect
- An adverse event related to the investigational device that meets seriousness criteria, including device malfunction or misuse that could have led to a serious outcome.
- Device deficiency
- An inadequacy of a medical device related to its identity, quality, durability, reliability, safety, or performance, including malfunction, use error, or labeling inadequacy.
- Device accountability
- The documented tracking of investigational device shipment, receipt, use, return, and disposal to ensure only enrolled subjects receive devices and quantities reconcile.
- Risk-based monitoring
- A monitoring approach that allocates oversight resources according to risks to subject safety and data quality, rather than uniform on-site visits for all sites.
- Source document verification
- The monitor's comparison of data recorded in the case report form against original source documents to confirm accuracy, completeness, and consistency.
- Essential documents
- Records demonstrating the investigation's conduct and quality, including the CIP, ethics approvals, consent forms, investigator CVs, device records, CRFs, and safety reports.
- Record retention period
- The required duration for maintaining investigation records after completion or termination, set by applicable regulation and the CIP, often at least two years after the last approval.
- Protocol deviation
- Any departure from the clinical investigation plan that does not meet the criteria for a protocol violation; it is documented, assessed for impact, and reported per the CIP.
- Protocol violation
- A significant departure from the CIP that may affect subject safety, rights, or data integrity, requiring prompt reporting to the sponsor and ethics committee.
- Investigational device exemption
- A regulatory authorization permitting an investigational device to be shipped and used in a clinical study to gather safety and effectiveness data before marketing approval.
- Clinical investigation report
- The final document prepared by the sponsor summarizing the investigation's rationale, methods, results, and conclusions, including safety and device performance data.
- Substantial equivalence
- A regulatory determination that a new device has the same intended use and comparable technological characteristics as a predicate device, supporting clearance via 510(k).