ACRP-MDP study plan
ACRP-MDP · Give each week a clear focus.
8 weeks · About 6 hours per week
Medical device clinical research core knowledge areas (per ACRP-MDP Exam Content Outline)
Draft a one-page map of the medical device development lifecycle from concept through post-market surveillance, labeling each phase with its governing purpose
Define and contrast the roles of sponsor, monitor, clinical investigator, and site staff in device trials, writing a short comparison table from memory
List the major device classification frameworks and explain in writing how risk class drives trial evidence requirements
Build a personal glossary of 25 core device research terms with your own definitions, flagging any you cannot define confidently
Your checkpoint
A 2-page lifecycle and roles reference sheet plus a 25-term glossary, self-scored for gaps
Medical device clinical research core knowledge areas (per ACRP-MDP Exam Content Outline)
Explain in writing how a device's risk determination shapes the clinical investigation plan and the level of evidence required
Summarize the purpose and required contents of an investigator's brochure or device manual without consulting notes
Describe how preclinical and bench testing feed into the decision to begin a clinical investigation
Distinguish intended use, indications for use, and contraindications using three original examples
Your checkpoint
A written 500-word explainer on risk-based evidence requirements, checked against your week 1 notes
Medical device clinical research core knowledge areas (per ACRP-MDP Exam Content Outline)
Outline the elements of a clinical investigation plan and state the purpose of each element in your own words
Explain the informed consent process for device trials, including what must be disclosed about device-specific risks
Describe safety reporting pathways for device-related adverse events and device deficiencies, distinguishing the two
Identify the records a site must maintain and explain the rationale for each
Your checkpoint
A one-page CIP element checklist annotated with the purpose of each element
Medical device clinical research core knowledge areas (per ACRP-MDP Exam Content Outline) & ICH and ISO 14155:2026-referenced medical device trial conduct (per ACRP-MDP Exam Content Outline)
Bridge from domain 1 to domain 2 by writing how ICH and ISO 14155 principles map onto the CIP elements you outlined
State the core ethical principles underlying human subject protection and connect each to a concrete trial safeguard
Explain the purpose of a trial master file and describe what belongs in it
Self-quiz on domain 1 material and log every item you miss into a running error log
Your checkpoint
A completed 40-question self-quiz on domain 1 with an error log and remediation notes
ICH and ISO 14155:2026-referenced medical device trial conduct (per ACRP-MDP Exam Content Outline)
Summarize the scope and structure of ISO 14155 and explain how it governs device trial conduct
Describe how ICH good clinical practice principles apply to device investigations and where device-specific guidance adds requirements
Explain the roles and responsibilities of sponsor, monitor, and investigator as set out in the standards, citing the concept rather than the clause number
Draft a monitoring visit flow from preparation through close-out
Your checkpoint
A standards crosswalk table mapping each major trial activity to its governing principle
ICH and ISO 14155:2026-referenced medical device trial conduct (per ACRP-MDP Exam Content Outline)
Explain the risk-based monitoring approach and justify how monitoring intensity should scale with trial risk
Describe source document verification, what it confirms, and common findings it surfaces
Outline deviation and noncompliance handling from detection through corrective action
Explain how protocol deviations are classified and what triggers escalation
Your checkpoint
A written monitoring and deviation-handling procedure in your own words, 1 to 2 pages
ICH and ISO 14155:2026-referenced medical device trial conduct (per ACRP-MDP Exam Content Outline)
Describe the essential elements of informed consent under the standards and identify common consent deficiencies
Explain safety reporting timelines and the investigator's and sponsor's respective obligations
Summarize requirements for statistical considerations and how the analysis population is defined
Explain the purpose and process of site close-out and record retention
Your checkpoint
A safety reporting and consent quick-reference card covering obligations and timing concepts
Medical device clinical research core knowledge areas (per ACRP-MDP Exam Content Outline) & ICH and ISO 14155:2026-referenced medical device trial conduct (per ACRP-MDP Exam Content Outline)
Re-quiz on your full error log and confirm every previously missed item is now answered correctly
Complete a timed mixed-domain practice set and analyze misses by domain to target final review
Teach two concepts aloud from each domain as if explaining to a new coordinator
Build a one-page exam-day sheet of the highest-yield concepts you keep missing
Your checkpoint
A full timed mixed-domain practice test score plus a one-page high-yield review sheet
Milestones
Week 2: Explain risk-based evidence requirements and device lifecycle from memory without notes
Week 4: Score at least 75% on the 40-question domain 1 self-quiz with all misses logged
Week 6: Produce the monitoring and deviation procedure and pass a self-check against your crosswalk
Week 8: Score at least 80% on the timed mixed-domain practice set with error log fully cleared