ACVREP CLVT flashcards
ACVREP CLVT · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Snellen acuity fraction
- The ratio of the test distance to the distance at which a normal eye could read the same line; 20/40 means a normal eye reads that line at 40 feet while the patient needs 20 feet.
- logMAR scale
- Logarithm of the minimum angle of resolution in arc minutes; each 0.1 logMAR step equals one line on a standard chart; 0.0 logMAR equals 20/20.
- M unit notation
- Near acuity unit where 1M equals the size of a 20/20 letter at 40 cm (1.45 mm x-height); useful for prescribing magnification and calculating reading add.
- Contrast sensitivity function
- Measures ability to detect gratings of varying spatial frequencies at low contrast; peak sensitivity around 3–6 cycles per degree; loss may occur with normal acuity.
- Pelli-Robson chart
- A contrast sensitivity test using large letters of decreasing contrast; scored in log contrast sensitivity units; normal is about 1.8 to 2.0.
- Ishihara plates
- Pseudoisochromatic plates used to screen for red-green color vision deficiency; not a test of blue-yellow defects; results are qualitative, not a threshold measure.
- Farnsworth D-15
- A color arrangement test with 15 caps; detects moderate to severe color vision defects and classifies them as protan, deutan, or tritan; pass/fail is dichotomous.
- Stereopsis testing
- Measures binocular depth perception using random-dot or contour targets (e.g., Titmus, Randot, TNO); thresholds reported in seconds of arc; absence suggests loss of binocularity.
- Preferred retinal locus
- A retinal area outside the fovea that a person with central vision loss uses for fixation; identified by microperimetry or scanning laser ophthalmoscopy; trained in eccentric viewing.
- MNREAD acuity chart
- A continuous-text reading chart that measures reading acuity, critical print size, and maximum reading speed; useful for prescribing magnification and predicting functional reading.
- Visual perceptual assessment
- Tests such as MVPT or TVPS evaluate visual discrimination, memory, spatial relations, figure-ground, and closure; distinguish perceptual deficits from acuity loss.
- Visual motor integration
- The ability to coordinate visual perception with motor output; assessed by Beery VMI, which requires copying geometric forms; relevant to handwriting and daily tasks.
- Confrontation visual field
- A quick screening test comparing the patient's field to the examiner's; detects gross defects but not subtle scotomas; normal temporal field is about 90 degrees.
- Humphrey visual field
- Static automated perimetry that measures threshold sensitivity in decibels at multiple points; produces reliability indices and pattern deviation plots for diagnosing and monitoring field loss.
- Essential job functions
- Fundamental duties of a job, including visual demands such as acuity, field, color discrimination, and near work; used to determine reasonable accommodations under ADA.
- O*NET database
- A U.S. Department of Labor database describing occupations, including required visual abilities and work activities; useful for matching low vision clients to suitable jobs.
- IEP and 504 plan
- Educational documents that specify accommodations and services for students with disabilities; for low vision, may include large print, magnification, lighting, and assistive technology.
- Lawton IADL scale
- A standardized measure of instrumental activities of daily living such as shopping, cooking, finances, and transportation; scored by independence level; useful for functional assessment.
- Barthel Index
- A measure of functional independence in basic ADLs (feeding, bathing, grooming, dressing, toileting, mobility, stairs); scores 0–100; higher scores indicate greater independence.
- NEI VFQ-25
- The National Eye Institute Visual Function Questionnaire, a 25-item measure of vision-related quality of life covering general health, vision, and psychosocial domains; scores 0–100.
- PHQ-9 depression screen
- A nine-item self-report questionnaire that screens for depression severity; scores 5, 10, 15, and 20 represent mild, moderate, moderately severe, and severe depression.
- MoCA cognitive screen
- Montreal Cognitive Assessment; a 30-point screening tool for mild cognitive impairment; scores below 26 suggest impairment; adjust for education and sensory loss.
- Screen reader software
- Assistive technology that converts digital text to speech or braille (e.g., JAWS, NVDA, VoiceOver); essential for computer access when vision is insufficient for screen reading.
- Video magnifier (CCTV)
- An electronic device that projects an enlarged image onto a screen; offers adjustable magnification, contrast, and color; useful for reading and near tasks.
- Handheld magnifier
- A convex lens used for spot reading; magnification depends on lens power and eye-to-lens distance; higher power yields smaller field and shorter working distance.
- Telescope magnification formula
- Magnification equals the focal length of the objective divided by the focal length of the eyepiece; higher magnification reduces field of view and requires steady fixation.
- Equivalent power formula
- For a near magnifier: equivalent power = F + (D × d), where F is lens power in diopters, D is accommodation or add, and d is lens-to-eye distance in meters.
- Eccentric viewing training
- Teaching a person with central scotoma to fixate with a preferred retinal locus; uses clock-face or quadrant cues and practice to improve reading and spotting.
- Glare control filters
- Tinted lenses (yellow, orange, gray, or polarized) that reduce glare and enhance contrast; selection depends on lighting conditions and task; avoid excessive darkness.
- Typoscope
- A non-optical device with a slot that isolates one line of text and blocks glare from surrounding white paper; improves reading comfort and tracking.
- Spotting with telescope
- The skill of locating and aligning a handheld telescope on a target; involves anchoring, scanning, and steadying; taught before distance viewing tasks.
- Device abandonment
- Discontinuation of a prescribed low vision device; causes include poor training, unrealistic expectations, discomfort, or inadequate magnification; address with follow-up and adjustment.