Arab Board Radiology Part 1 study materials
Arab Board Radiology Part 1 study resources

Arab Board Radiology Part 1 key terms

Arab Board Radiology Part 1 · Get comfortable with the vocabulary.

Hounsfield unit (HU)

A calibrated scale expressing the linear attenuation coefficient of a tissue relative to water, where water is 0 and air is about -1000. It allows objective comparison of tissue density on CT images.

Related: Window width and level, Beam hardening artifact
Window width and level

Display settings that map a chosen range of CT attenuation values onto the available grey scale. Level sets the midpoint brightness and width sets the contrast span, allowing soft tissue or bone to be viewed optimally.

Related: Hounsfield unit (HU)
Beam hardening artifact

Dark streaks or cupping produced when a polychromatic X-ray beam preferentially loses low-energy photons as it traverses tissue. It is most prominent between dense structures such as bone or metal.

Related: Hounsfield unit (HU), Compton scatter
Photoelectric effect

Absorption of an X-ray photon by an inner-shell electron, which is ejected while the photon disappears entirely. Its probability rises steeply with atomic number and falls with increasing photon energy, driving bone and contrast visibility.

Related: Compton scatter, K-edge
Compton scatter

Interaction in which a photon transfers part of its energy to an outer-shell electron and is deflected in a new direction. It degrades image contrast and is the main source of occupational radiation exposure in fluoroscopy.

Related: Photoelectric effect, Scatter radiation and scatter grid
K-edge

A sudden increase in photoelectric absorption that occurs when photon energy just exceeds the binding energy of an atom's innermost shell. It explains why iodine and barium provide strong contrast at diagnostic energies.

Related: Photoelectric effect, Iodinated contrast medium
Half-value layer (HVL)

The thickness of a specified material that reduces the intensity of an X-ray beam to half its original value. It is a standard measure of beam quality and filtration adequacy.

Related: Filtration and collimation, ALARA principle
ALARA principle

The practice of keeping radiation doses as low as reasonably achievable, taking economic and social factors into account. It underpins protocol optimisation, shielding and dose monitoring in every imaging modality.

Related: Half-value layer (HVL), Effective dose, Diagnostic reference level
Effective dose

A whole-body dose equivalent that reflects the relative radiosensitivity of exposed organs, expressed in sieverts. It allows comparison of stochastic risk between different examinations and modalities.

Related: ALARA principle, Stochastic and deterministic effects
Stochastic and deterministic effects

Stochastic effects, such as cancer induction, have no threshold and their probability rises with dose. Deterministic effects, such as skin erythema, occur only above a threshold and increase in severity with dose.

Related: Effective dose, Linear no-threshold model
Linear no-threshold model

A radiation protection assumption that cancer risk increases linearly with dose from zero, with no safe threshold. It is used conservatively for setting dose limits despite uncertainty at very low doses.

Related: Stochastic and deterministic effects, Effective dose
Committed equivalent dose

The total radiation dose delivered to an organ or tissue over 50 years after intake of a radionuclide. It accounts for the biological half-life and decay of the incorporated isotope.

Related: Radionuclide generator, Effective dose
Radionuclide generator

A device containing a long-lived parent isotope that continuously produces a shorter-lived daughter, which is eluted for imaging. The technetium-99m generator, using molybdenum-99, is the commonest example.

Related: Committed equivalent dose, Positron emission tomography (PET)
Positron emission tomography (PET)

An imaging technique that detects pairs of annihilation photons emitted when positrons from a radiotracer meet electrons. It maps metabolic activity, most often with fluorine-18 fluorodeoxyglucose.

Related: Standardised uptake value (SUV), Radionuclide generator
Standardised uptake value (SUV)

A semi-quantitative measure of radiotracer accumulation in a lesion, normalised to injected activity and body size. It is used to grade malignancy and assess treatment response on PET studies.

Related: Positron emission tomography (PET)
Iodinated contrast medium

A water-soluble compound containing iodine that attenuates X-rays, used to opacify vessels and organs. Modern agents are usually low-osmolar monomers or dimers and carry risks of allergy-like and renal reactions.

Related: Contrast-induced nephropathy, Anaphylactoid reaction, K-edge
Contrast-induced nephropathy

An acute rise in serum creatinine occurring within days of intravascular iodinated contrast administration, after other causes are excluded. Risk is greatest with pre-existing renal impairment, diabetes and dehydration.

Related: Iodinated contrast medium, Gadolinium-based contrast agent
Anaphylactoid reaction

A non-immunological, allergy-like adverse reaction to contrast medium that does not require prior sensitisation. It ranges from urticaria to bronchospasm and hypotension and is managed with antihistamines, steroids and adrenaline.

Related: Iodinated contrast medium
Gadolinium-based contrast agent

A paramagnetic chelate that shortens T1 relaxation and brightens tissues on MRI. It is avoided in severe renal failure because of the risk of nephrogenic systemic fibrosis.

Related: Nephrogenic systemic fibrosis, Contrast-induced nephropathy
Nephrogenic systemic fibrosis

A rare fibrosing disorder of skin and internal organs linked to gadolinium exposure in patients with severely impaired renal function. Risk is minimised by screening renal function and using stable macrocyclic agents.

Related: Gadolinium-based contrast agent
T1 and T2 relaxation

Time constants describing how nuclear magnetisation recovers along the main field (T1) and decays in the transverse plane (T2) after a radiofrequency pulse. Tissue differences in these times generate MRI contrast.

Related: Gadolinium-based contrast agent, Gradient echo sequence
Gradient echo sequence

An MRI pulse sequence that refocuses signal by reversing magnetic field gradients rather than using a 180-degree radiofrequency pulse. It permits fast imaging and is sensitive to susceptibility and flow.

Related: T1 and T2 relaxation, Susceptibility artifact
Susceptibility artifact

Local signal loss and geometric distortion caused by differences in magnetic susceptibility between tissues, notably near metal or air. It is exaggerated on gradient echo sequences and can obscure adjacent structures.

Related: Gradient echo sequence
Scatter radiation and scatter grid

Scatter radiation consists of deflected photons that blur the image and increase staff dose. An anti-scatter grid of alternating lead and spacer strips absorbs much of it before it reaches the detector.

Related: Compton scatter, Filtration and collimation
Filtration and collimation

Filtration removes low-energy photons from the beam before the patient, reducing skin dose. Collimation restricts the field to the region of interest, reducing patient dose and scatter production.

Related: Half-value layer (HVL), Scatter radiation and scatter grid
Diagnostic reference level

A dose benchmark, usually set at the third quartile of a survey of typical practice, used to flag examinations with unusually high patient doses. Exceeding it prompts protocol review rather than a legal breach.

Related: ALARA principle, Effective dose
PACS and DICOM

PACS is the networked archive that stores and distributes medical images. DICOM is the international standard governing image file format and communication between scanners, workstations and archives.

Adequate image quality (diagnostic acceptability)

The level of contrast, resolution and noise sufficient to answer the clinical question at the lowest reasonable dose. Optimisation balances these factors rather than maximising any single one.

Related: ALARA principle, Modulation transfer function
Modulation transfer function

A measure of how faithfully an imaging system reproduces spatial frequencies, describing resolution performance. It falls off at high frequencies, indicating the limit of detectable detail.

Related: Adequate image quality (diagnostic acceptability)
Hepatobiliary phase imaging

A delayed MRI phase, typically 20 minutes after a hepatocyte-specific gadolinium agent, in which functioning liver takes up contrast and appears bright while most lesions appear dark. It improves detection of hepatic lesions.

Related: Gadolinium-based contrast agent, T1 and T2 relaxation
Bowel wall stratification

The layered enhancement pattern of normal small bowel on contrast-enhanced CT, reflecting mucosa, submucosa and muscularis. Loss of stratification suggests transmural inflammation, ischaemia or tumour.

Apparent diffusion coefficient (ADC)

A calculated map derived from diffusion-weighted imaging that quantifies water molecule mobility in tissue. Low values indicate restricted diffusion, seen in infarction, abscess and highly cellular tumours.

Related: Gradient echo sequence, Positron emission tomography (PET)
Fleischner Society guidelines

Evidence-based recommendations for managing incidentally detected pulmonary nodules, based on size, morphology and patient risk. They define when to follow up with CT, when to use PET, and when to biopsy or stop surveillance.

Related: Standardised uptake value (SUV)
BI-RADS

A standardised lexicon and reporting system for breast imaging that assigns a final assessment category from 0 to 6. Each category carries a defined likelihood of malignancy and a recommended management pathway.

Related: Digital breast tomosynthesis
Digital breast tomosynthesis

A breast imaging technique that acquires multiple low-dose projections over an arc and reconstructs thin slices through the breast. It reduces tissue overlap and improves cancer detection in dense breasts.

Related: BI-RADS
Seldinger technique

A method of gaining vascular or cavity access by puncturing with a needle, passing a guidewire, removing the needle and then advancing a catheter over the wire. It is the foundation of most interventional procedures.

Related: Embolisation
Embolisation

Deliberate occlusion of a blood vessel by injecting particles, coils, glue or balloons through a catheter. It is used to control bleeding, treat vascular malformations and devascularise tumours.

Related: Seldinger technique, Transarterial chemoembolisation
Transarterial chemoembolisation

Delivery of chemotherapy directly into a tumour's arterial supply followed by embolisation of those vessels. It is used mainly for intermediate-stage hepatocellular carcinoma, exploiting the tumour's arterial dominance.

Related: Embolisation, Hepatobiliary phase imaging