Quick reference

Radiation Protection

  • Occupational effective dose limit is 20 mSv per year averaged over five years, with no single year above 50 mSv; public effective dose limit is 1 mSv per year.

  • Equivalent dose limits are 20 mSv per year for the lens and 500 mSv per year for skin and extremities in occupational exposure.

  • A declared pregnant worker's fetus should receive no more than 1 mSv additional dose during the declared pregnancy.

  • ALARA is the decision rule that dose is kept as low as reasonably achievable while diagnostic information remains sufficient.

  • For a point source, intensity follows the inverse square law: I1/I2 equals the square of d2/d1.

  • Half-value layer is the material thickness that reduces beam intensity by half; the linear attenuation coefficient equals 0.693 divided by the half-value layer.

  • Diagnostic lead aprons are at least 0.35 mm Pb equivalent; 0.5 mm Pb equivalent is used for higher-kVp or interventional workloads.

  • Collimation reduces irradiated volume and scatter; gonadal shielding is indicated when it does not obscure the diagnostic region.

Quick reference

Dosimetry and Radiation Biology

  • Absorbed dose is measured in gray, where one gray equals one joule per kilogram.

  • Equivalent dose in sieverts equals absorbed dose in gray multiplied by the radiation weighting factor.

  • Effective dose in sieverts equals the sum of tissue equivalent doses multiplied by tissue weighting factors.

  • Radiation weighting factors are 1 for x-rays and gamma rays, 2 for protons, and 20 for alpha particles.

  • ICRP 103 tissue weighting factors include 0.12 each for red marrow, colon, lung, stomach, and breast, and 0.08 for gonads.

  • Stochastic effects have no threshold; probability rises with dose while severity is independent of dose, as in cancer induction.

  • Deterministic effects have a threshold; severity increases with dose, as in skin erythema and cataract.

  • The human whole-body LD50/60 without medical support is approximately 4 Gy.

Quick reference

Radiographic Physics

  • Thermionic emission from the cathode supplies electrons; tube current in milliamperes controls photon quantity.

  • Tube voltage in kVp controls electron acceleration and therefore beam quality and penetration.

  • Bremsstrahlung produces a continuous spectrum; characteristic radiation produces discrete peaks determined by target atomic number.

  • Exposure is proportional to mAs when mA and exposure time change inversely; mAs equals mA multiplied by seconds.

  • Attenuation follows I equals I0 times e raised to minus mu x, where mu is the linear attenuation coefficient and x is thickness.

  • Photoelectric absorption varies strongly with atomic number and photon energy; Compton scatter depends on electron density.

  • Added filtration uses aluminum equivalent to remove low-energy photons and increase half-value layer.

  • Magnification equals source-to-image distance divided by source-to-object distance.

Quick reference

Equipment and Imaging Informatics

  • Computed radiography uses a photostimulable phosphor plate read by a laser; direct digital radiography uses a thin-film transistor array.

  • DICOM defines image file format, metadata, and network services; PACS stores and displays images; RIS manages scheduling and reports.

  • HL7 is used for clinical and administrative messaging such as order and worklist exchange.

  • Exposure index is a vendor-specific measure of detector signal; deviation index compares actual exposure index with target.

  • DICOM grayscale standard display function is used to calibrate diagnostic monitors for perceptual linearity.

  • Automatic exposure control uses ionization chambers or detector feedback and a backup timer to terminate exposure.

  • Lossless image compression preserves diagnostic data; lossy compression discards data and is restricted by clinical policy.

  • Detector flat-field calibration corrects gain and offset variations and reduces fixed-pattern noise.

Quick reference

Radiographic Positioning and Procedural Technique

  • AP means the beam enters anteriorly; PA means it enters posteriorly; lateral and oblique projections are named by beam entry and patient position.

  • A PA chest radiograph is upright at 180 cm source-to-image distance, taken at full inspiration, with scapulae rotated clear of lung fields.

  • A supine AP abdomen radiograph is typically taken at 100 cm source-to-image distance and includes diaphragm to symphysis pubis for a KUB.

  • An upright abdominal radiograph is used to demonstrate air-fluid levels when bowel obstruction is suspected.

  • Cervical spine lateral and open-mouth odontoid views assess alignment and the atlantoaxial joint.

  • Trauma imaging uses cross-table lateral or modified projections when the patient cannot be turned.

  • Two orthogonal views of an extremity are standard because a single view may miss or misrepresent a fracture.

  • Pediatric immobilization and collimation reduce motion and dose; shielding is placed only when it does not obscure anatomy.

Quick reference

Image Quality

  • Subject contrast depends on tissue attenuation differences; receptor contrast depends on detector response and display.

  • Spatial resolution is expressed in line pairs per millimeter and is limited by focal spot size, detector element size, and motion.

  • Modulation transfer function describes how well a system transfers spatial frequencies; higher values indicate better resolution.

  • Quantum mottle is noise from insufficient photons; increasing mAs increases photons and reduces mottle.

  • Signal-to-noise ratio compares signal amplitude with noise; contrast-to-noise ratio compares lesion-to-background difference with noise.

  • Window level controls displayed brightness; window width controls displayed contrast in computed tomography and digital images.

  • Geometric unsharpness increases with larger focal spot, shorter source-to-object distance, and longer object-to-image distance.

  • Size distortion is magnification; shape distortion includes elongation and foreshortening from oblique object orientation.

Quick reference

Image Evaluation and Quality Assurance

  • Repeat analysis classifies rejected images by cause such as positioning, exposure, artifact, or equipment fault.

  • Daily quality control for digital radiography includes uniformity, collimation, and artifact checks with a test phantom.

  • Monitor quality control uses test patterns and luminance measurements to verify display consistency.

  • Acceptance testing establishes baseline performance before clinical use; periodic testing compares performance with that baseline.

  • CR artifacts include plate scratches, dust, ghosting, and light leaks; DR artifacts include dead pixels, lag, and calibration errors.

  • Dose audit uses dose-area product and exposure index to compare practice with diagnostic reference levels.

  • Corrective action is documented when quality control results exceed tolerance limits.

Quick reference

Cross-Sectional Anatomy

  • The axial plane divides superior from inferior; coronal divides anterior from posterior; sagittal divides left from right.

  • Hounsfield units assign water zero, air about minus 1000, and dense bone about plus 1000.

  • The mediastinum contains the aorta, superior vena cava, pulmonary arteries, trachea, esophagus, and lymph nodes.

  • Upper abdominal cross-sections show liver, spleen, kidneys, pancreas, aorta, inferior vena cava, and bowel.

  • Brain cross-sections show gray matter, white matter, ventricles, falx cerebri, and tentorium cerebelli.

  • Pelvic cross-sections show bladder, rectum, reproductive organs, iliac vessels, and pelvic bones.

  • Spinal cross-sections show vertebral body, spinal canal, cord or cauda equina, nerve roots, and intervertebral disc.

Quick reference

Physiology and Pathology Correlation

  • Air appears lucent on radiographs; pneumothorax shows absent lung markings and a visible pleural line.

  • Pleural effusion appears dense and blunts the costophrenic angle on an upright chest radiograph.

  • Cardiomegaly is present when the cardiothoracic ratio exceeds 0.5 on a frontal adult chest radiograph.

  • Bowel obstruction may show dilated loops and air-fluid levels on upright abdominal images.

  • Free intraperitoneal air appears as subdiaphragmatic lucency on an upright chest or abdominal radiograph.

  • Fractures appear as lucent lines or cortical steps; healing callus may appear as sclerosis or new bone.

  • Renal obstruction can produce hydronephrosis, seen as dilated calyces and pelvis on ultrasound or contrast imaging.

  • Many malignant lesions enhance after contrast because of increased vascularity and capillary permeability.

Quick reference

Patient Care

  • Two patient identifiers, such as full name and date of birth, are confirmed before every examination.

  • Adult resting vital signs are approximately heart rate 60 to 100 per minute, respiratory rate 12 to 20 per minute, and oxygen saturation 94 to 100 percent on room air.

  • Informed consent requires capacity, adequate disclosure, understanding, and voluntary agreement.

  • Immobilization devices and padding improve image quality and reduce patient injury.

  • Oxygen is stored away from open flame and electrical spark sources.

  • Venipuncture uses aseptic technique; extravasation requires stopping injection and assessing the site.

  • Pregnancy screening is documented before examinations that may irradiate the pelvis or abdomen.

  • Patient education uses plain language, teach-back, and interpreter services when needed.

Quick reference

Contrast Media and Emergency Management

  • Iodinated contrast media can cause mild urticaria, moderate bronchospasm, or severe hypotension and airway compromise.

  • Severe anaphylactoid contrast reaction is treated with stopping contrast, airway support, oxygen, intravenous fluids, and intramuscular epinephrine.

  • Barium sulfate is avoided when gastrointestinal perforation or leak is suspected; water-soluble iodinated contrast is used instead.

  • Gadolinium is avoided in severe renal impairment because of nephrogenic systemic fibrosis risk.

  • Metformin may be withheld around iodinated contrast in significant renal impairment according to local protocol.

  • Contrast extravasation management includes stopping injection, removing the cannula, elevating the limb, and monitoring neurovascular status.

  • Adult cardiopulmonary resuscitation uses compressions at 100 to 120 per minute and a depth of 5 to 6 cm.

  • Syncope is managed by lying the patient flat, elevating the legs, and monitoring airway and circulation.

Quick reference

Infection Prevention and Control

  • Standard precautions apply to all patients and include hand hygiene, gloves, gown, mask, eye protection, and safe injection practice.

  • Hand hygiene is performed before and after patient contact and after contact with body fluids or contaminated equipment.

  • Contact precautions require gloves and gown; droplet precautions require a mask; airborne precautions require an N95 respirator and negative-pressure room.

  • Alcohol-based hand rub is preferred for routine hand hygiene except when hands are visibly soiled or when caring for patients with C. difficile.

  • Needle-stick management includes washing the site, reporting immediately, and following post-exposure prophylaxis protocol.

  • Sterilization destroys all microorganisms including spores; disinfection reduces pathogens but may not destroy all spores.

  • Blood and body-fluid spills are contained, cleaned with detergent, and disinfected with an approved agent.

  • Regulated medical waste is segregated according to local infection-control and environmental rules.

Quick reference

Occupational Safety

  • A personal dosimeter is worn at chest or collar level outside the lead apron; a second badge is worn under the apron when required.

  • Lead apron, thyroid shield, and lead eyewear reduce occupational dose during fluoroscopy and mobile radiography.

  • Time, distance, and shielding are the three basic controls for occupational radiation exposure.

  • Lifting uses a wide base, bent knees, straight back, and team assistance for heavy or uncooperative patients.

  • RACE means rescue, alarm, contain, and evacuate; PASS means pull, aim, squeeze, and sweep for fire extinguishers.

  • Electrical equipment is inspected, grounded, and kept away from liquids.

  • Latex allergy requires latex-free gloves, tubing, and supplies.

  • Workplace violence response includes activating security, maintaining distance, and avoiding confrontation.

Quick reference

Professional Practice, Ethics, Communication and Health Law

  • Informed consent requires a competent patient, adequate information, understanding, and voluntary agreement.

  • Confidentiality requires sharing patient information only with authorized persons who need it for care or as permitted by law.

  • DHA licensure defines the legal scope of practice; radiographers perform only procedures within that scope.

  • Documentation is contemporaneous, objective, accurate, and includes patient identity, procedure, contrast, and adverse events.

  • The four ethical principles are autonomy, beneficence, nonmaleficence, and justice.

  • Negligence requires duty, breach of duty, causation, and damages.

  • Mandatory reporting includes suspected child abuse, elder abuse, and specified communicable diseases as required by law.

  • Social media posts must not contain protected health information or identifiable patient images.