DHA Radiology / Radiographer key terms
DHA Radiology / Radiographer · Get comfortable with the vocabulary.
- ALARA
- Related: Effective dose, Time, distance and shielding, Beam collimation
A radiation protection principle requiring that patient and staff doses be kept as low as reasonably achievable, weighing economic and practical factors while still obtaining the diagnostic information needed.
- Occupational dose limit
- Related: Personnel dosimeter, ALARA, Deterministic effect
The maximum radiation dose a classified radiation worker may receive in a stated period, typically 20 mSv per year averaged over five years and 50 mSv in any single year.
- Personnel dosimeter
- Related: Occupational dose limit, ALARA
A badge or device worn by a radiation worker that records cumulative radiation dose, usually by thermoluminescence or optically stimulated luminescence, and is read periodically to verify compliance with dose limits.
- Time, distance and shielding
- Related: Inverse square law, Half-value layer, ALARA
The three practical methods for reducing radiation exposure: minimising time near a source, increasing distance because dose falls with the square of distance, and inserting absorbing material.
- Half-value layer
- Related: Time, distance and shielding, Occupational dose limit
The thickness of a given material that reduces the intensity of a radiation beam to half its original value, used to describe beam quality and to plan shielding.
- Beam collimation
- Related: ALARA, Grid ratio, Effective dose
Restricting the x-ray beam with adjustable shutters or cones so that only the region of clinical interest is irradiated, which lowers patient dose and reduces scattered radiation reaching the receptor.
- Primary barrier
- Related: Half-value layer, Time, distance and shielding
A protective structure, such as a lead-lined wall or door, thick enough to attenuate the useful beam that may be aimed directly at it, unlike secondary barriers that stop only scatter and leakage.
- Effective dose
- Related: Equivalent dose, Stochastic effect, ALARA
A whole-body risk indicator, in sieverts, obtained by multiplying each organ's equivalent dose by a tissue weighting factor and summing the results so that different examinations can be compared.
- Equivalent dose
- Related: Effective dose, Stochastic effect
The average absorbed dose in a tissue multiplied by a radiation weighting factor reflecting the biological harm of that radiation type; it is expressed in sieverts.
- Stochastic effect
- Related: Deterministic effect, Effective dose, Occupational dose limit
A radiation effect, such as cancer or heritable mutation, for which the probability of occurrence increases with dose while severity does not, and for which no threshold is assumed.
- Deterministic effect
- Related: Stochastic effect, Occupational dose limit
A tissue reaction such as skin erythema, epilation or cataract in which severity rises with dose and a practical threshold must be exceeded before the effect appears.
- Inverse square law
- Related: Time, distance and shielding, Source-to-image receptor distance (SID)
The principle that the intensity of radiation from a point source is inversely proportional to the square of the distance, so tripling the distance reduces intensity to one ninth.
- Focal spot
- Related: Object-to-image receptor distance (OID), Spatial resolution, Source-to-image receptor distance (SID)
The small area on the anode where electrons strike and x-rays are generated; a smaller focal spot sharpens detail, while a larger one tolerates greater tube current and heat.
- Bremsstrahlung radiation
- Related: Half-value layer, Focal spot
X-rays produced when incident electrons are deflected and slowed by target nuclei, generating a continuous spectrum of photon energies whose maximum equals the kilovoltage peak.
- mAs reciprocity law
- Related: Automatic exposure control (AEC), Exposure index
The rule that receptor exposure depends on the product of tube current and exposure time, so different milliampere and time combinations giving the same mAs produce comparable image receptor exposure.
- Automatic exposure control (AEC)
- Related: mAs reciprocity law, Exposure index, Beam collimation
A device using chambers or detectors to measure radiation reaching the image receptor and terminate the exposure at a preset level, compensating for differences in patient thickness and attenuation.
- DICOM
An international standard that defines the format and communication protocols for medical images and associated data, enabling equipment from different manufacturers to store and exchange studies reliably.
- Window width and level
- Related: Hounsfield unit, Spatial resolution
Display controls that define the range of pixel values mapped to visible grey shades and the centre of that range, allowing structures of similar attenuation to be seen clearly.
- Source-to-image receptor distance (SID)
- Related: Object-to-image receptor distance (OID), Inverse square law, Focal spot
The distance from the x-ray tube focal spot to the image receptor, which affects magnification, spatial resolution and the radiation intensity reaching the receptor.
- Object-to-image receptor distance (OID)
- Related: Source-to-image receptor distance (SID), Focal spot
The distance between the anatomical structure of interest and the image receptor; increasing it magnifies the structure and reduces the geometric sharpness of the recorded image.
- Radiographic projection
- Related: Source-to-image receptor distance (SID), Object-to-image receptor distance (OID)
The path of the central ray through the patient to the image receptor, named by the direction of entry and exit, for example anteroposterior or posteroanterior.
- Grid ratio
- Related: Beam collimation, Spatial resolution
The height of the lead strips of an anti-scatter grid divided by the distance between them; a higher ratio removes more scatter but requires more precise alignment and higher dose.
- Detective quantum efficiency (DQE)
- Related: Modulation transfer function (MTF), Exposure index
A measure of how effectively an imaging system converts incident x-ray quanta into image signal while adding as little noise as possible, expressed as a percentage at a stated dose.
- Modulation transfer function (MTF)
- Related: Detective quantum efficiency (DQE), Spatial resolution
A measure of how well an imaging system transfers contrast at different spatial frequencies from object to image, indicating its ability to reproduce fine detail.
- Spatial resolution
- Related: Modulation transfer function (MTF), Focal spot, Object-to-image receptor distance (OID)
The ability of an imaging system to show two small structures close together as separate, often expressed as line pairs per millimetre or as the smallest discernible detail.
- Exposure index
- Related: Automatic exposure control (AEC), mAs reciprocity law
A number reported for a digital radiograph that indicates how much radiation reached the image receptor, used to judge technique adequacy rather than displayed image brightness.
- Reject image analysis
- Related: Exposure index, ALARA
A periodic review of radiographs that were repeated or discarded, classifying the reasons so that positioning, technique or equipment faults can be corrected and repeat dose reduced.
- Quality control
- Related: Reject image analysis, Exposure index
Scheduled tests and measurements of equipment performance, such as collimation accuracy, tube output and detector uniformity, compared with accepted limits to detect faults before they affect images.
- Hounsfield unit
- Related: Window width and level
A number on the computed tomography attenuation scale in which water is zero, air is about minus one thousand, and denser tissues have positive values.
- Axial plane
- Related: Hounsfield unit, Window width and level
A cross-sectional plane dividing the body into upper and lower portions, perpendicular to the long axis, which is the standard plane of computed tomography images.
- Radiopacity and radiolucency
Appearances on a radiograph: structures that absorb x-rays strongly appear white and are termed radiopaque, while those transmitting x-rays appear dark and are termed radiolucent.
- Patient identification
- Related: Informed consent, Pregnancy screening
Verifying identity using at least two independent details, such as full name and date of birth or file number, before any examination, procedure or administration of contrast.
- Pregnancy screening
- Related: ALARA, Effective dose, Patient identification
Questioning patients of childbearing age about possible or known pregnancy before ionising examinations so that the procedure, shielding or timing can be adjusted to protect a fetus.
- Iodinated contrast medium
- Related: Extravasation, Anaphylactoid reaction
A water-soluble iodine-containing agent that attenuates x-rays and is given to outline blood vessels, organs or the urinary tract; concentration and osmolality affect tolerance and image quality.
- Extravasation
- Related: Iodinated contrast medium
Leakage of intravenously injected contrast medium from a vein into surrounding soft tissue, causing pain and swelling and occasionally skin injury; the injection must stop immediately.
- Anaphylactoid reaction
- Related: Iodinated contrast medium, Extravasation
A severe, immunoglobulin E-independent reaction to contrast medium with urticaria, bronchospasm or hypotension that can occur on first exposure and requires prompt emergency treatment.
- Standard precautions
- Related: Hand hygiene
Infection control measures applied to every patient regardless of diagnosis, including hand hygiene, gloves, gowns, eye protection and safe handling of sharps and body fluids.
- Hand hygiene
- Related: Standard precautions
Cleaning the hands with soap and water or an alcohol-based rub at specified moments, such as before and after patient contact, which is the single most effective way to prevent cross-infection.
- Informed consent
- Related: Patient identification
A patient's voluntary agreement to an examination after receiving understandable information about its purpose, benefits, risks, alternatives and consequences, recorded before the procedure starts.
- Confidentiality
- Related: Informed consent
The legal and ethical duty to keep patient health information, including images and reports, private and to share it only with people involved in the patient's care or as authorised.