Hazardous Materials Management and Regulatory Compliance

  • RCRA hazardous waste = solid waste that is listed (F, K, P, U) or exhibits a characteristic: ignitability, corrosivity, reactivity, or toxicity (40 CFR 261).

  • RCRA generator categories: very small quantity generator <100 kg/month; small quantity generator 100–1,000 kg/month; large quantity generator ≥1,000 kg/month; acute hazardous waste has lower limits.

  • CERCLA releases at or above a reportable quantity require notification to the National Response Center; EPCRA section 304 also requires state and local notification.

  • EPCRA Tier II inventory is due March 1 annually for hazardous chemicals at or above 10,000 lb on site, or at lower thresholds for extremely hazardous substances.

  • DOT HMR: the 49 CFR 172.101 Hazardous Materials Table sets proper shipping name, hazard class, packing group, labels, and packaging requirements.

  • OSHA HazCom 29 CFR 1910.1200 requires safety data sheets with 16 sections and GHS-aligned labels: product identifier, hazard statements, pictograms, signal word, precautionary statements, supplier.

  • Land disposal restrictions (40 CFR 268) require treatment to meet standards before land disposal or prohibit disposal.

  • A uniform hazardous waste manifest tracks waste from generator through transporter to the TSDF; the generator retains a signed copy and confirms receipt.

Quick reference

Environmental Science

  • BOD5 measures oxygen consumed by microbes over 5 days at 20°C; COD measures chemical oxygen demand and includes nonbiodegradable organics.

  • First-order decay: C = C0 e^(−kt); half-life t1/2 = 0.693/k.

  • Henry's law: Cwater = KH × Pgas; high KH favors volatilization; low KH favors partitioning to water.

  • Log Kow correlates with lipid solubility and bioaccumulation; higher log Kow generally means greater bioconcentration but very high values may reduce bioavailability.

  • Darcy flux q = K i; seepage velocity v = q/n_e, where K is hydraulic conductivity, i is gradient, and n_e is effective porosity.

  • Clean Water Act NPDES permits regulate point-source discharges; TMDLs allocate pollutant loads when water bodies fail standards.

  • Clean Air Act NAAQS cover CO, lead, NO2, ozone, particulate matter, and SO2.

  • NEPA decision path: categorical exclusion, environmental assessment leading to finding of no significant impact, or environmental impact statement.

Quick reference

Chemistry and Toxicology

  • pH = −log[H+]; each unit is a tenfold change in hydrogen ion activity.

  • LD50/LC50: lower values indicate greater acute toxicity; route, species, and exposure duration affect comparability.

  • Dose-response: NOAEL is highest dose without adverse effect; LOAEL is lowest with adverse effect; uncertainty factors derive reference doses.

  • ADME: absorption, distribution, metabolism, excretion determine toxicant fate; metabolism may detoxify or bioactivate.

  • IARC groups: 1 carcinogenic to humans; 2A probably carcinogenic; 2B possibly carcinogenic.

  • Organic contaminant mobility often increases with lower Kow and higher water solubility; sorption reduces mobility.

  • Redox reactions transfer electrons; oxidation loses electrons, reduction gains electrons; redox potential indicates oxidizing or reducing conditions.

  • Hydrolysis, photolysis, and biodegradation are abiotic or biotic transformation pathways that can change toxicity and persistence.

Quick reference

Occupational Safety and Health

  • OSHA PELs are enforceable 8-hour TWA limits; ACGIH TLVs and NIOSH RELs are nonregulatory or recommended.

  • Hierarchy of controls: elimination, substitution, engineering controls, administrative controls, PPE last.

  • Respiratory protection: atmosphere-supplying respirators required for IDLH or oxygen-deficient atmospheres; APF estimates protection.

  • Permit-required confined space: test oxygen, flammables, and toxics before entry; acceptable oxygen is 19.5–23.5% by volume.

  • HAZWOPER 29 CFR 1910.120 covers emergency response and cleanup; Level A is a fully encapsulating vapor-protective suit with SCBA.

  • Noise: OSHA 8-hour PEL is 90 dBA; hearing conservation program at 85 dBA; 5-dB exchange rate.

  • Heat stress assessed by WBGT; acclimatization and work/rest cycles reduce risk.

  • OSHA recordkeeping: work-related fatalities within 8 hours; in-patient hospitalizations, amputations, and eye loss within 24 hours.

Quick reference

Emergency Planning and Response

  • NIMS/ICS: span of control typically 3–7 with optimum 5; Unified Command is used when multiple agencies have jurisdiction.

  • HAZWOPER emergency response requires a site-specific preplan, PPE, decontamination, and incident command.

  • EPCRA: LEPCs develop emergency plans for extremely hazardous substances; facilities notify SERC and LEPC.

  • Hot zone = contaminated or exposure area; warm zone = contamination reduction; cold zone = support and command.

  • Shelter-in-place is chosen when evacuation would increase exposure; close windows, doors, HVAC, and seal openings.

  • CERCLA and Clean Water Act release notifications go to the National Response Center; EPCRA 304 notifications go to SERC and LEPC.

  • Emergency action plan elements: reporting, alarms, evacuation routes, accounting, and rescue or medical duties.

  • Initial isolation and protective action distances increase with release size and wind conditions; downwind protection is primary.

Quick reference

Hazardous Waste Treatment, Storage, Disposal, and Remediation

  • Treatment train: physical (sedimentation, filtration, air stripping, carbon), chemical (neutralization, precipitation, oxidation/reduction), biological, thermal.

  • TCLP estimates leachability of hazardous constituents from waste; results determine toxicity characteristic and land disposal compliance.

  • Solidification/stabilization immobilizes contaminants but does not destroy them; long-term stability and leaching must be monitored.

  • RCRA incinerators must achieve 99.99% DRE for principal organic hazardous constituents; dioxin/furan standards may require 99.9999%.

  • Subtitle C landfill design: double liner, leachate collection and removal, groundwater monitoring, closure, and financial assurance.

  • SVE removes VOCs from unsaturated soil; air sparging adds air below the water table to strip VOCs into the vadose zone.

  • Pump-and-treat hydraulically contains dissolved plumes but may require decades; PRBs treat groundwater in situ.

  • Bioremediation relies on microbial degradation; nutrients, electron acceptors, temperature, and bioavailability control rates.