Quick reference

Institutional Door Hardware and Locking Devices

  • ANSI/BHMA grades rank commercial locks by duty: Grade 1 is highest-duty, Grade 2 is medium-duty, and Grade 3 is light-duty or residential.

  • A fail-secure electric strike stays locked when power is removed and unlocks only when energized.

  • Classroom function: outside key locks or unlocks the door while the inside lever remains free for egress at all times.

  • Office function: outside key and inside thumbturn can each control the locked or unlocked state.

  • Panic hardware must release with no more than 15 lbf applied in the direction of egress travel.

  • Fire door assemblies must use labeled hardware; field modification can void the label unless the assembly is evaluated.

  • Door closer adjustments: sweep controls closing from open to near-latch, latch speed controls final closing, and backcheck cushions opening.

  • SFIC small-format interchangeable cores and LFIC/FSIC large-format interchangeable cores are not dimensionally interchangeable.

  • Dogging holds an exit device latch retracted for convenience and is prohibited on fire-rated door assemblies.

Quick reference

Master Keying and Key Control Systems

  • Key hierarchy: the grand master key operates all locks, a master key operates a subset, and a change key operates one lock or one identically keyed group.

  • A master key has additional cuts that align pin stacks to the master shear line; a change key aligns only its own shear line.

  • MACS limits the difference between adjacent cuts to reduce binding and wear; the allowable value is keyway- and manufacturer-specific.

  • A control key removes and installs an interchangeable core and is separate from operating keys and master keys.

  • Construction keying uses temporary construction keys and cores; turnover to permanent keys makes construction keys inoperative.

  • Patented keyways limit unauthorized duplication through controlled key-blank distribution; a 'Do Not Duplicate' stamp alone is not legal enforcement.

  • A key control log tracks holder, key stamp, issue date, return date, and associated lock or core.

  • Key audit matches issued keys to locks and cores and identifies unaccounted keys; rekeying is required when key control is lost.

Quick reference

Electrified Hardware, Access Control, and Life-Safety Interface

  • Fail-safe means unlocked on loss of power; fail-secure means locked on loss of power.

  • A maglock is fail-safe and requires a code-compliant egress release arrangement where allowed.

  • A request-to-exit device signals egress intent; a door position switch reports open or closed status; neither substitutes for the other.

  • OSDP is bidirectional access-control communications supporting encrypted Secure Channel; Wiegand is typically unidirectional.

  • Voltage drop formula: Vdrop = 2 × L × I × R, where L is one-way length, I is current, and R is conductor resistance per unit length.

  • Delayed egress locks must release within 15 seconds after force is applied to the door and must sound a local alarm.

  • Access-controlled egress doors require an egress-side sensor, a manual release, and release on fire alarm or power loss.

  • Fire alarm relays should release fail-safe locks; a fail-secure lock needs a mechanical override to provide compliant egress.

  • Power supply sizing must account for continuous load, alarm load, battery standby, and voltage at the device.

Quick reference

Codes, Standards, Specifications, and Facility Security Administration

  • IBC is a model building code; NFPA 101 is the Life Safety Code; both regulate means of egress and occupancy requirements.

  • Panic hardware is generally required on egress doors serving assembly or educational occupancies with an occupant load of 50 or more.

  • ADA limits interior hinged door opening force to 5 lbf and requires hardware operable without tight grasping, pinching, or wrist twisting.

  • NFPA 80 requires fire door assemblies to be inspected and tested after installation and at least annually thereafter.

  • MasterFormat Division 08 covers openings, doors, frames, and door hardware; Division 28 covers electronic safety and security.

  • A door hardware specification should define function, grade, finish, fire rating, handing, cylinder/keying, and electrification.

  • Security administration uses risk assessment, key control, access records, visitor logs, and incident reporting to manage facility risk.

  • CPTED principles include natural surveillance, natural access control, territorial reinforcement, and maintenance.

  • UL 10C evaluates fire door assemblies under positive pressure; UL 305 covers fire exit hardware.