AMPP Bridge Coatings study materials
AMPP Bridge Coatings study resources

AMPP Bridge Coatings cheat sheet

AMPP Bridge Coatings · Keep the key ideas within reach.

Quick reference

Surface Preparation and Substrate Condition

  • SSPC-SP 5/NACE No. 1 white metal blast removes all visible rust, mill scale, coating, and foreign matter; the finished steel has a uniform gray color.

  • SSPC-SP 10/NACE No. 2 near-white blast permits only slight streaks or stains on at most 5% of each unit area; at least 95% must be clean.

  • SSPC-SP 6/NACE No. 3 commercial blast removes visible residues but allows tightly adherent material; about two-thirds of the surface must be free of visible residues.

  • SSPC-SP 2 hand-tool and SSPC-SP 3 power-tool cleaning are used where blast cleaning is not permitted or practical; they do not create a deep anchor profile.

  • Surface profile is measured with ASTM D4417 methods; nozzle pressure, abrasive type and size, angle, and standoff distance control anchor-pattern depth.

  • ISO 8502-6 Bresle extraction with ISO 8502-9 conductivity conversion quantifies soluble salts; acceptance limits are project-specific and commonly reported in micrograms per square centimeter.

  • A common environmental rule is steel temperature at least 3 degrees Celsius, about 5 degrees Fahrenheit, above dew point; condensation after cleaning or before coating can cause adhesion failure.

  • Blasting abrasive must be dry and free of oil, grease, and salts; ASTM D4940 conductivity testing checks soluble ionic contamination.

Quick reference

Coating Materials, Selection, and Specification

  • Wet film thickness equals dry film thickness times 100 divided by percent volume solids; this calculation sets spray-pass coverage and verifies wet-film checks.

  • Theoretical coverage in square feet per gallon equals 1604 times the volume-solids fraction divided by dry-film thickness in mils; actual coverage is lower because of overspray, loss, and surface roughness.

  • Volume solids and volatile organic compound content come from product data and test methods such as ASTM D2697 and EPA Method 24.

  • Inorganic zinc silicate primers provide galvanic protection to steel; they usually need humidity to cure and require a compatible tie coat before topcoating.

  • Aliphatic polyurethane topcoats resist ultraviolet degradation and retain gloss and color; epoxy topcoats chalk and yellow when exposed to sunlight.

  • ISO 12944 corrosivity categories C1 through C5 and expected service life drive coating-system selection for bridge environments.

  • A recoat window is product-specific; exceeding the maximum interval usually requires abrasion, cleaning, and sometimes a tie coat to restore adhesion.

  • Specifications should state surface preparation grade, profile, primer, intermediate, topcoat, dry-film thickness ranges, stripe coats, recoat limits, color, volatile organic compound limits, and acceptance tests.

Quick reference

Coating Application and Environmental Conditions

  • Before application, verify product data limits for air and steel temperature, relative humidity, dew point, recoat time, and pot life; record readings.

  • Airless spray atomization depends on tip orifice, fan angle, fluid pressure, and coating viscosity; a test spray pattern identifies tip wear or clogging.

  • Two-component coatings must be mixed at the specified volume ratio; some products require an induction time before spray application.

  • Pot life is counted from mixing; material that gels, skins, or exceeds pot life is discarded rather than thinned for use.

  • Stripe coats are applied by brush or roller to welds, edges, fasteners, cutouts, and back-to-back angles before full spray coats.

  • Each spray pass typically overlaps the previous pass by about 50%; this reduces thin streaks and missed areas on large bridge surfaces.

  • If the maximum recoat window is exceeded, the surface is abraded and cleaned, and the manufacturer's repair procedure is followed.

  • Ventilation and dehumidification control solvent concentration, humidity, and cure; forced cure must remain within product data limits.

Quick reference

Inspection, Testing, and Quality Control

  • An inspection and test plan lists hold points, witness points, acceptance criteria, sampling frequency, and records for each coating operation.

  • SSPC-PA 2 dry-film thickness measurement commonly uses five spot measurements per 100 square feet, with each spot the average of three gauge readings.

  • Dry-film gauges are verified on the actual substrate and on shims; measurements near edges, corners, and welds are treated separately.

  • Wet-film thickness is checked with ASTM D4414 comb gauges during application and converted to predicted dry-film thickness.

  • Adhesion is assessed by ASTM D3359 cross-cut tape testing for thin films or ASTM D4541 pull-off testing for thicker systems.

  • Holiday detection uses ASTM D5162 low-voltage wet-sponge testing for thin films and high-voltage spark testing for thicker films, at specified voltages.

  • Visual surface preparation is compared with SSPC-VIS 1 or ISO 8501-1 reference photographs; the specified blast grade must be documented.

  • Nonconformance reports record location, description, disposition, corrective action, and closure verification for out-of-specification work.

Quick reference

Safety, Regulations, and Project Documentation

  • OSHA 29 CFR 1926.62 regulates construction lead exposure and requires exposure assessment, respiratory protection, hygiene facilities, blood-lead monitoring, and training.

  • OSHA 29 CFR 1926.1153 limits respirable crystalline silica; abrasive blasting controls include containment, ventilation, wet methods where feasible, and respirators.

  • Permit-required confined spaces require atmospheric testing, ventilation, an attendant, rescue arrangements, and entry authorization under OSHA 29 CFR 1910.146.

  • Respiratory protection requires medical clearance, fit testing, training, and cartridge or supplied-air selection based on contaminant and exposure level.

  • EPA Method 24 measures volatile organic compound content; project specifications and local air permits set volatile organic compound and solvent-handling limits.

  • Spent abrasive, paint waste, solvents, and contaminated containment are characterized and managed under RCRA and project waste plans.

  • Safety data sheets have sixteen sections and provide hazard, handling, personal protective equipment, first-aid, storage, and disposal information for each coating product.

  • Project records include daily logs, environmental readings, inspection reports, nonconformance reports, material certificates, and as-built coating documentation.