Wet to dry film conversion
Dry film thickness equals wet film thickness multiplied by the volume solids fraction. A 10 mil wet film at 60 percent volume solids yields 6 mils dry, ignoring application losses.
Theoretical coverage formula
Coverage in square feet per gallon equals 1604 times the volume solids fraction divided by dry film thickness in mils. This gives the maximum coverage before losses.
Stripe coat purpose
A stripe coat is a thin extra coat applied by brush to edges, welds, and corners before or after the main coat to build film where spray tends to thin out.
Recoat window
The specified time interval during which the next coat may be applied without surface preparation. Exceeding it typically requires abrasion or solvent wiping to restore adhesion.
Induction time
The required standing period after mixing components and before application for certain catalyzed products. It is specified on the product data sheet and varies by temperature.
Airless spray characteristics
Airless spray forces material through a small tip at high pressure, typically 1,500 to 3,000 psi, producing less overspray than conventional air spray for high-solids coatings.
Dew point spread rule
Substrate temperature minus dew point. Most specifications require a spread of at least about 5 degrees Fahrenheit (3 degrees Celsius) before coating to prevent condensation.
Volume solids meaning
The fraction of a coating that remains as dry film after solvents evaporate. It is used in coverage and wet-to-dry thickness calculations and is listed on the data sheet.
SSPC-SP 5 white metal
Abrasive blast cleaning to a white metal finish with a uniform gray-white color and no visible rust, scale, or foreign matter. It is the highest blast cleanliness grade.
SSPC-SP 10 near-white
Abrasive blast cleaning that leaves at most five percent of the surface with light shadows, streaks, or stains. It is commonly specified for immersion service.
SSPC-SP 6 commercial blast
Abrasive blast cleaning that removes all visible oil, grease, dirt, and scale but permits staining and up to about one-third of the surface with slight residues.
Surface profile measurement
The roughness of a blasted surface, measured with a comparator or profile gauge. Typical angular profiles for high-performance systems are about 1.5 to 4 mils.
SSPC-SP 1 solvent cleaning
Removal of oil, grease, dirt, and similar contaminants by solvent, detergent, or steam before mechanical preparation. It prevents contaminants from being driven into the surface during blasting.
SSPC-SP 2 and SP 3
Hand tool and power tool cleaning that remove loose rust and scale but leave tightly adherent material. They do not achieve the cleanliness of abrasive blasting.
SSPC-SP 11 bare metal
Power-tool cleaning to bare metal, removing all visible coatings, rust, and scale from the surface. It is used where blasting is not permitted or practical.
SSPC-SP 12 waterjetting grades
Waterjetting cleanliness grades WJ-1 through WJ-4, paired with flash rust grades L, M, and H that describe the severity of rusting after waterjetting.
Soluble salt testing
Measurement of chlorides and sulfates on prepared surfaces by conductivity or ion-specific kits. Residual salts above specification limits cause premature coating failure.
Abrasive cleanliness requirement
Blasting abrasive must be clean, dry, and free of oil or salt contamination. Recycled abrasive can carry chlorides and fines that degrade the profile and adhesion.
Dry film thickness gauge types
Type 1 gauges use magnetic pull-off; Type 2 gauges are electronic. Eddy-current gauges measure nonconductive coatings on nonferrous substrates such as aluminum.
DFT measurement practice
Take a minimum of three readings per specified area, such as 100 square feet, and average them. No single reading should fall below the specified minimum.
Holiday testing purpose
High-voltage or low-voltage spark testing detects pinholes, thin spots, and discontinuities in a coating. Voltage is set per coating thickness and the product data sheet.
Pull-off adhesion test
A test per ASTM D4541 that measures the tensile force required to detach a coating. Results report strength in psi and the failure mode, cohesive or adhesive.
Hold point definition
A step in the work that cannot proceed without inspector approval. A witness point requires notification but not necessarily approval before work continues.
Environmental inspection readings
Recorded during inspection: air temperature, substrate temperature, relative humidity, dew point, and the dew point spread. These determine whether application conditions are acceptable.
Cure verification methods
Solvent rub, hardness, or cure tests confirm a coating has cured. Topcoating over an undercured coat can cause wrinkling or solvent entrapment and adhesion loss.
Instrument calibration documentation
Gauges should be verified and calibration documented before use. Readings on curved or edge surfaces are unreliable and should be avoided or corrected.
Confined space atmospheric testing
Testing for oxygen, flammables, and toxics before entry. Entry requires a permit, an attendant, and a rescue plan in addition to acceptable readings.
Silica dust hazard
Abrasive blasting with silica-containing media generates respirable dust. Controls include respiratory protection and dust suppression per applicable occupational exposure limits.
VOC content meaning
The mass of volatile organic compounds per unit volume of coating. Low-VOC and waterborne products reduce emissions and may require different application equipment.
Bonding and grounding
Flammable liquids require bonding and grounding during transfer to prevent static ignition. This applies to solvent and coating handling in addition to storage requirements.
Waste characterization
Spent abrasive, paint waste, and solvent rags are regulated wastes that must be characterized and disposed of per applicable environmental rules, not ordinary trash.
Isocyanate respiratory protection
Isocyanate-containing products require supplied-air or appropriate cartridge protection per the safety data sheet. Spray application in enclosed areas also requires ventilation.