Peeling Polyurethane on the Clarifiers

AMPP CIP Level 2 · Put your knowledge to work in context.

All case studies

Peeling Polyurethane on the Clarifiers

A municipal wastewater plant is coating the exteriors of four 60-ft-diameter clarifiers. The specified system is a zinc-rich epoxy primer at 3–5 mils, an amine-adduct epoxy intermediate at 5–7 mils, and an acrylic-aliphatic polyurethane finish at 2–3 mils over SSPC-SP 10 steel. Work runs in late October: air 52°F, steel 49°F, dew point 46°F, RH 88%, no forced ventilation and no dehumidification. The product data sheet states a 24-hour maximum recoat interval at 75°F, but at these temperatures the contractor holds the primer 18 hours and topcoats the intermediate 24 hours after application. Ten days later the owner reports the finish peeling in sheets across the lower third of each shell. Beneath the peel, the epoxy has a chalky, waxy, pale film and feels soapy.

1. Diagnose the failure mechanism. What in the job conditions drove it?

Read the worked answer

This is amine blush (carbamate formation) causing intercoat delamination.

Mechanism: amine-adduct epoxy hardeners at the film surface react with atmospheric carbon dioxide and moisture to form ammonium carbamate - a waxy, water-soluble, alkaline residue. It is not visible in all light, but it destroys the chemical and mechanical bond the next coat needs.

Why here:

  • 88% RH and steel only 3°F above dew point - moisture is plentiful at the surface; a 3°F margin is thin and condensation on a cold shell overnight is very likely. The lower third of the shell is the coldest, wettest zone, which matches where the peel is worst.
  • 49°F steel is likely below or at the PDS minimum application temperature for the epoxy, so cure is slow and incomplete, extending the blush-forming window.
  • No ventilation/dehumidification - still, humid air sits on the film.
  • Recoat intervals exceeded: the 24-hour maximum recoat window on the data sheet is referenced to 75°F. Whatever the true window at 52°F, the contractor topcoated on an arbitrary 24-hour schedule rather than a measured cure state.

The polyurethane finish never bonded to the contaminated epoxy; the peel is purely intercoat adhesion loss.

2. What field checks confirm the diagnosis, and what else must you investigate before recommending a repair?

Read the worked answer

Confirmation checks:

  • Water-break / wetting test: water droplets bead and refuse to wet a blush-contaminated surface; on clean epoxy they spread and hold a continuous film.
  • pH check: press pH paper against a water-wetted area - carbamate is alkaline, so a reading well above neutral supports blush.
  • Solvent rub: blush rubs off as a soapy smear.
  • Visual: pale haze or whitish bloom on the epoxy, especially on the cold lower shell.

Additional investigation before repair:

  • Determine the actual failure plane with pull-off tests or a knife peel: is it only finish-to-intermediate, or has the intermediate also lost bond to the primer or to the steel? If the epoxy itself is undercured at 49°F, the whole system may be compromised and patching is pointless.
  • Gather cure records: surface temperature and RH logs, product batch numbers, mix ratios.
  • Check whether the finish failure includes CO2 bubbling/pinholing - moisture-cure urethanes and polyurethanes applied at 88% RH can also show bubbles, which points to an additional application defect.
  • Sample low, middle and upper shell - the moisture gradient tells you whether this is a condensation problem (cold wall) or a plant-wide practice problem.

3. What corrective action and what specification/prevention changes do you recommend?

Read the worked answer

Corrective:

  1. Remove the unbonded finish over the whole affected zone - do not spot-patch; delamination at the peel edge means the bond is failing beyond what you can see.
  2. Wash the exposed epoxy with warm water and a mild detergent or the manufacturer's recommended cleaner, scrubbing, then rinse with clean water. Blush is water-soluble; washing, not sanding alone, removes it.
  3. Abrade the washed surface to a dull, uniform profile, then re-check with a water-break test and allow to dry fully.
  4. Re-apply the finish within the recoat window and verify adhesion on a test patch before releasing the rest of the shell.
  5. If pull-off shows the intermediate is also undercured or debonded, remove the full system to bare steel.

Prevention / specification changes:

  • Mandate a wash-and-abrade step for amine epoxies whenever the recoat window is exceeded, and write it into the specification as a hold point.
  • Require heating and dehumidification so steel is at least 5°F above dew point and within the PDS temperature range, with logged readings at the point of application.
  • Replace the arbitrary "24 hours" recoat timer with documented PDS recoat windows at the actual temperature, and add a cure check before topcoating.
  • Consider a blush-resistant hardener grade for cold, humid work.