AMPP Corrosion Specialist flashcards
AMPP Corrosion Specialist · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Corrosion cell components
- Four elements must coexist for electrochemical corrosion: an anode where metal oxidizes, a cathode where reduction occurs, an electrolyte conducting ions between them, and a metallic path carrying electrons. Eliminating any one arrests the corrosion.
- Faraday's law
- The mass of metal dissolved is proportional to current multiplied by time: m equals M times I times t divided by n times F, where F is 96,485 coulombs per mole.
- Nernst equation
- At 25 degrees C, E equals E-standard minus 0.0592 divided by n, multiplied by the logarithm of the reaction quotient. It gives the actual half-cell potential at the prevailing ion activity.
- Pourbaix diagram
- A potential versus pH map showing thermodynamic regions of immunity, passivity, and corrosion for a metal in water. It predicts tendency to corrode but provides no kinetic rate information.
- Differential aeration cell
- Corrosion driven by oxygen concentration differences. The oxygen-depleted region acts as the anode and corrodes, while the oxygen-rich region acts as the cathode. It commonly occurs under deposits and in crevices.
- Pitting potential
- The potential above which a passive metal undergoes localized breakdown and pitting in a given environment. Higher values indicate greater resistance to chloride attack and a wider passive range.
- Stress corrosion cracking
- Cracking produced by the simultaneous action of tensile stress and a specific corrosive environment, such as chloride for austenitic stainless steel, caustic for carbon steel, or ammonia for brass.
- Dezincification
- Selective leaching of zinc from brass, leaving a porous copper-rich residue with little strength. It occurs in copper-zinc alloys exposed to stagnant, low-flow water with high chloride or low pH.
- Corrosion rate unit conversion
- One mil per year equals 0.0254 millimetres per year. A uniform current density of one microamp per square centimetre corresponds to about 11.6 micrometres per year for iron.
- Galvanic series
- A ranking of metals and alloys by their open-circuit potentials measured in seawater. Coupling alloys far apart in the series increases galvanic current and accelerates attack on the more active material.
- Pitting resistance equivalent number
- Calculated as percent chromium plus 3.3 times percent molybdenum plus 16 times percent nitrogen. Values above roughly 40 indicate good resistance to chloride pitting in seawater and marine service.
- Anodic area ratio effect
- When a small anode is coupled to a large cathode, the cathodic current concentrates on a small area, producing rapid deep penetration. Design should maximize anodic area and minimize cathodic area.
- Corrosion allowance
- Extra wall thickness added to a component so that predictable uniform metal loss over the design life does not breach the minimum required thickness. It does not protect against pitting or cracking.
- Sour service limits
- NACE MR0175 and ISO 15156 apply when hydrogen sulfide partial pressure exceeds 0.00035 MPa (0.05 psi). Carbon steels are then restricted to a maximum hardness of 22 HRC.
- Duplex stainless properties
- Grades with a mixed ferritic-austenitic microstructure giving roughly twice the yield strength of austenitic grades, with high chromium and molybdenum for chloride resistance in marine and process service.
- Dissimilar metal insulation
- Where different metals must be joined, an insulating gasket, washer, or transition piece breaks the electrical path, preventing galvanic current from driving corrosion of the more active alloy.
- Cathodic protection current demand
- Bare steel in flowing seawater needs roughly 100 to 110 milliamps per square metre, whereas a well-coated structure may need only 1 to 25 milliamps per square metre. Coating condition drives anode sizing.
- Cathodic protection criterion
- A pipe-to-electrolyte potential of minus 0.85 volts or more negative, measured against a copper/copper sulfate reference electrode, is the accepted protection criterion for steel in soil and natural waters.
- 100 mV polarization criterion
- A potential shift of at least 100 millivolts from the free-corrosion potential, in either the cathodic or anodic direction, indicates adequate cathodic protection of buried or submerged steel.
- Impressed current cathodic protection
- A rectifier supplies direct current to inert anodes, delivering high, adjustable protection current over large structures. It can cause stray-current interference and overprotection if not controlled.
- Galvanic anode cathodic protection
- Sacrificial zinc, aluminium, or magnesium anodes corrode to supply protective current to the structure. The system is simple and self-regulating but limited in current output and environment resistivity.
- Anodic inhibitor
- A chemical that forms or thickens a passive film over anodic areas. Underdosing is dangerous because the remaining unprotected anodes experience concentrated, rapid localized attack.
- Risk based inspection
- An API 580 and 581 methodology ranking equipment by the likelihood and consequence of failure, then assigning inspection methods, coverage, and intervals proportionate to the calculated risk.
- Integrity operating window
- A defined range for process parameters such as temperature, pH, velocity, and contaminant concentration within which identified corrosion mechanisms remain at an acceptable rate. Exceedances trigger documented action.
- Linear polarization resistance
- A technique applying a small potential perturbation and measuring the resulting current to obtain an instantaneous corrosion rate. It requires a continuous, conductive aqueous phase to work reliably.
- Remaining life calculation
- Current measured thickness minus minimum required thickness, divided by the corrosion rate, gives remaining service life. The rate used should reflect the most severe credible damage mechanism.
- Half-cell potential survey
- Measurement of structure-to-electrolyte potentials with a portable reference electrode, usually at regular intervals along a buried pipeline, to map cathodic protection effectiveness and locate coating defects.
- Close interval survey
- Pipe-to-soil potential readings taken at one to three metre intervals with cathodic protection current interrupted, resolving protection gaps and coating defects that widely spaced surveys would miss.
- Wenner four-pin method
- A soil resistivity test injecting current through outer pins and measuring voltage between inner pins. Resistivity indicates soil corrosivity and guides galvanic anode groundbed design and placement.
- Direct current voltage gradient
- A coating survey that maps voltage gradients in the soil above a buried pipeline while cathodic protection current flows, pinpointing coating holidays and areas of active corrosion.
- Microbiologically influenced corrosion
- Deterioration caused or accelerated by microorganisms, typically sulfate-reducing bacteria. It produces localized pitting, black iron sulfide deposits, sulfide odour, and attack in low-flow sections.
- Failure analysis sequence
- A structured investigation: collect background and operating history, document and preserve the failure, sample and photograph, perform laboratory examination, then confirm the mechanism before recommending corrective action.