AMPP CP1 Tester flashcards
AMPP CP1 Tester · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Rectifier lockout and tagout
- Before opening a rectifier cabinet, de-energize the AC supply and apply a lock and tag. Input line voltage is lethal and is separate from the DC output hazard.
- Induced AC touch hazard
- Pipelines running parallel to power lines can carry induced AC voltage, creating touch and step potential hazards. Measure AC voltage to remote earth before contacting the structure.
- Confined space test stations
- Test stations inside pits or vaults may accumulate oxygen-deficient air, hydrogen sulfide, or flammable gas. Test the atmosphere with a calibrated multi-gas meter before entry.
- Copper sulfate electrolyte hazard
- Saturated copper sulfate solution irritates skin and eyes and is toxic to aquatic life. Wear gloves and eye protection, contain spills, and dispose of waste per regulations.
- Temporary bond polarity check
- Reversed DC connections on temporary bonds can cause arcing, unexpected structure potentials, and shock. Verify polarity with a meter before energizing any temporary circuit.
- Portable reference electrode comparison
- Compare a copper/copper sulfate half-cell against a second portable reference in the same electrolyte. A difference above about 5 millivolts indicates contamination or a blocked junction.
- Voltmeter input impedance requirement
- Pipe-to-soil potential measurements require a voltmeter with at least 10 megohms input impedance. Lower impedance draws current through the soil and produces a biased reading.
- Wenner soil resistivity formula
- Soil resistivity equals two pi times pin spacing times measured resistance, rho = 2 pi a R. Use consistent units, such as centimeters and ohms to obtain ohm-centimeters.
- Current interrupter timing verification
- Verify interrupter on and off timing with a timing device or oscilloscope before a survey. GPS-synchronized units protecting one structure must start and stop together.
- Copper sulfate to SCE conversion
- A copper/copper sulfate reference reads about 76 millivolts more negative than saturated calomel for the same structure. Add roughly 76 millivolts to express a copper sulfate reading versus SCE.
- Instant-off potential
- An instant-off reading is taken immediately after interrupting cathodic protection current. It excludes the resistive IR voltage drop in soil, leaving the true polarized potential of the structure.
- 100 mV polarization criterion
- A structure meets this criterion when its potential has shifted at least 100 millivolts in the cathodic direction from the native, depolarized potential, measured as an instant-off value.
- Non-interruptible current sources
- Galvanic anodes, solar panels, TEGs, and foreign rectifiers that cannot be interrupted contaminate instant-off readings. Identify and account for them before interpreting survey data.
- Rectifier no-output troubleshooting
- When a rectifier shows no DC output, check the AC supply voltage, fuse, tap setting, and diode or stack condition, then confirm with a clamp-on DC ammeter.
- -850 mV CSE criterion
- The minus 850 millivolt copper sulfate criterion applies to the polarized potential with IR drop removed. Applying it to an IR-included reading can leave the structure underprotected.
- Stray DC interference detection
- Structure-to-soil potentials that shift in step with another structure's current cycle indicate stray DC interference. Map potentials with the foreign source switched on and off.
- Close interval survey spacing
- Close interval surveys typically record structure-to-soil potentials at one to three meter intervals, with tighter spacing in congested areas and near coating defect indications.
- DCVG percent IR
- In direct current voltage gradient surveys, percent IR compares a defect's voltage gradient to the total pipe-to-soil voltage shift, ranking the relative severity of coating defects.
- Native potential measurement
- Native potential is measured after all cathodic protection current has been off long enough for the structure to depolarize, sometimes days. It is the baseline for polarization criteria.
- Current requirement test
- A temporary anode bed and power source apply current to the structure while potentials are recorded, showing how much current is needed to reach the protection criterion.
- Half-cell placement
- Place the reference electrode in undisturbed, moist soil as close to the structure as practical. Pavement, dry backfill, and gravel raise contact resistance and bias the reading.
- Out-of-trend reading verification
- Repeat any reading that differs sharply from adjacent data, and check lead continuity, electrode contact, and AC noise before accepting or rejecting the recorded value.
- Field record required elements
- Each reading is recorded with date, time, test point identification, structure, reference electrode type, instrument serial number, calibration date, and technician name.
- Stating CP criterion
- Reports must name the protection criterion applied, such as minus 850 millivolts instant-off or 100 millivolts polarization, and state whether IR drop was removed.
- Rectifier operating log
- Log the date, time, AC input voltage, tap or mode setting, DC output volts and amps, and any adjustment made during the rectifier inspection visit.
- As-found and as-left
- Record the rectifier or system condition before adjustment and after adjustment, so reviewers can see exactly what changed and who authorized it.
- Data traceability and backup
- Back up raw logger files before leaving site. Unsaved, unsigned, or uncorrected data cannot be defended as a record of the survey.
- Pipe-to-soil lead connections
- Connect the structure to the voltmeter positive terminal and the reference electrode to the negative or common terminal. A negative reading indicates cathodic polarity.
- IR drop in readings
- Current flowing through soil resistance between structure and reference adds an IR error that drives readings more negative. Interrupting the current and reading instant-off removes it.
- AC voltage to remote earth
- Measure AC voltage between the structure and a remote earth reference to assess induced AC exposure. Values near or above 15 volts are commonly treated as requiring mitigation review.
- Shunt current calculation
- Current through an anode or bond equals the measured millivolt drop divided by one thousand, then divided by the shunt resistance in ohms.
- Telluric current effects
- Naturally occurring earth currents from solar activity cause slow potential fluctuations that can mimic cathodic protection changes. Compare repeat readings taken minutes apart during quiet periods.