AMPP CP1 Tester study plan
AMPP CP1 Tester · Give each week a clear focus.
8 weeks · About 7 hours per week
Job Site Safety
List every hazard category on a CP test site (electrical, traffic, excavation, confined space, chemical) and write a control for each from memory
Assemble and explain the PPE set required before energizing or de-energizing a rectifier
Demonstrate the safe shutdown/startup sequence for an impressed current rectifier on paper, including lockout/tagout steps
Explain shock hazards of AC vs DC and state minimum approach distances and grounding practices
Describe emergency response steps for a colleague contacting an energized structure or test lead
Your checkpoint
A one-page pre-job hazard assessment form you filled out for a simulated rectifier inspection, scored against a 12-item checklist with 100% of critical items present
Equipment Setup and Calibration Support
Identify each component of a cathodic protection test station and state its function
Set up a multimeter, reference electrode, and test leads for a structure-to-electrolyte potential measurement and describe each connection
Perform and record a reference electrode calibration check against a second electrode, noting acceptance limits
Diagnose common setup faults: reversed polarity, open reference electrode, high-resistance soil contact, and stray AC pickup
Explain when and why a current interrupter is installed and how to verify synchronization between units
Your checkpoint
A completed equipment setup and calibration log covering 5 simulated setups, with a written cause-and-fix note for each of 4 injected faults
Equipment Setup and Calibration Support & System Operation
Trace the DC circuit of a rectifier from transformer through bridge to anode bed and structure, labeling each element
Adjust rectifier tap settings and describe the effect of each change on output current and voltage
Compare galvanic and impressed current system operating characteristics and state when each is selected
Explain how interference currents arise from foreign structures and describe a bond mitigation approach
Describe what a current interrupter does to the measured potential and how to select an interrupt cycle
Your checkpoint
A hand-drawn rectifier and anode bed circuit diagram with output readings recorded for three tap settings, plus a one-paragraph interpretation of the trend
System Operation & Field Data Collection and Testing
Plan a structure-to-electrolyte potential survey: define test point spacing, reference electrode placement, and contact technique
Collect and record at least 20 simulated potential readings, distinguishing instant-off from native and polarized values
Apply the -850 mV and 100 mV polarization shift criteria to a data set and state which criterion each reading satisfies
Explain how IR drop enters a potential reading and describe at least three ways to reduce it
Compute soil resistivity from a four-pin Wenner spacing setup and interpret the result for anode bed design
Your checkpoint
A field data sheet with 20 recorded potentials, a criteria determination for each, and a written summary flagging which locations fail the protection criterion
Field Data Collection and Testing & Field Measurement
Convert raw field readings into corrected values, applying reference electrode offset and meter calibration factors
Measure and interpret close interval survey data to locate a coating holiday or current pickup zone
Calculate current requirement from structure surface area and current density, and compare it to measured rectifier output
Explain how coating quality, soil resistivity, and temperature affect measured potentials and measurement confidence
Identify out-of-tolerance measurements and state the retest or verification step for each
Your checkpoint
A worked measurement problem set of 10 calculations (resistivity, current requirement, IR-corrected potential) with all answers within tolerance of the key
Documentation and Reporting & Field Measurement
Compile a survey record set that a second tester could reproduce: date, weather, soil conditions, instrument IDs, calibration status, and reading locations
Write test method descriptions for potential survey, soil resistivity, and rectifier output checks in your own words
Organize field notes and photos into a report structure with an executive summary, methods, results, and conclusions
Document a non-conformance or anomalous reading with the observation, likely cause, and recommended follow-up
Verify that all recorded values carry correct units, significant figures, and reference electrode identification
Your checkpoint
A complete 4-6 page mock CP survey report for a simulated site, including a data table, one figure, and a conclusions section that states pass/fail against the applicable criterion
Job Site Safety & Documentation and Reporting
Re-derive the safety controls for the three highest-risk tasks and compare them against your week 1 hazard form, correcting any gaps
Review reporting requirements and rewrite any conclusions that are unsupported by the recorded data
Explain the tester's scope of work and when to escalate an out-of-scope condition to a certified specialist
Produce concise written explanations of 10 core concepts suitable for a field apprentice
Your checkpoint
A revised hazard assessment plus a self-audit checklist that scores your week 6 report on traceability, completeness, and claim-to-data support
Job Site Safety & Equipment Setup and Calibration Support & System Operation & Field Data Collection and Testing & Documentation and Reporting & Field Measurement
Work through full-length practice sets for all six domains under timed conditions
Tabulate wrong answers by domain and re-study the two weakest domains with focused drills
Recite the protection criteria, calibration acceptance limits, and safety shutdown sequence from memory without notes
Rehearse explaining a complete CP test from setup to report in under 10 minutes
Your checkpoint
Two timed practice exams completed with scores logged by domain and a written list of the 10 facts you missed most often, each restated correctly from memory
Milestones
Week 2: Can complete a hazard assessment and set up a potential measurement with correct polarity and calibration check, unaided, in under 15 minutes
Week 4: Scores at least 80% on a self-made 30-question set covering safety, setup/calibration, and system operation
Week 6: Produces a mock survey report that a peer can follow from raw data to conclusion with no missing instrument or location identifiers
Week 8: Scores at least 85% on two timed full-domain practice exams with no domain below 75%