Ohm's law
Ohm's law states that voltage equals current multiplied by resistance, V = I × R; it is used to calculate CP circuit current, voltage drops, and groundbed resistance effects.
Kirchhoff's current law
Kirchhoff's current law states that the total current entering a circuit node equals the total current leaving it, which supports analysis of parallel CP current paths and bonds.
Series circuit resistance
In a series circuit, resistances add directly: R_total equals the sum of individual resistances. Series elements carry the same current and divide voltage across each resistance.
Parallel circuit resistance
In a parallel circuit, the reciprocal of total resistance equals the sum of the reciprocals of individual resistances. Parallel paths share current inversely according to their resistance.
850 mV CSE criterion
The 850 mV criterion requires a structure-to-electrolyte potential at least −850 mV versus copper/copper sulfate with cathodic protection applied, with IR drop considered.
100 mV polarization criterion
The 100 mV criterion accepts cathodic protection when the structure is polarized at least 100 mV from its native potential to its polarized potential, measured after IR drop is removed.
Instant-off potential
Instant-off potential is measured immediately after all CP current is interrupted. It removes most IR drop and approximates the true polarized potential of the structure.
Overprotection
Overprotection is excessive negative polarization, often below about −1.2 V versus copper/copper sulfate. It can cause coating disbondment, hydrogen evolution, and hydrogen embrittlement.
Close interval survey
A close interval survey measures pipe-to-soil potentials at closely spaced intervals along a pipeline, commonly every 1 to 2.5 meters, to identify coating and CP problems.
Wenner four-pin method
The Wenner method measures soil resistivity using four equally spaced pins. Resistivity equals 2πaR, where a is pin spacing and R is measured resistance.
DCVG survey
Direct current voltage gradient surveying locates coating defects by detecting voltage gradients in the soil caused by CP current discharging at holidays.
Current interrupter
A current interrupter periodically switches CP current on and off so technicians can measure instant-off potentials and separate IR drop from true polarization.
Magnesium anode
Magnesium galvanic anodes have an open-circuit potential near −1.75 V versus copper/copper sulfate and are used in moderate- to high-resistivity soils for steel structures.
Zinc anode
Zinc galvanic anodes have an open-circuit potential near −1.10 V versus copper/copper sulfate and are used in low-resistivity soils and seawater.
Galvanic anode backfill
Galvanic anode backfill, typically gypsum and bentonite, lowers anode-to-soil resistance and promotes uniform anode consumption by maintaining a conductive environment.
Anode consumption rate
Anode consumption rate is the mass of anode material consumed per ampere-year. Typical values are about 8.8 lb/A·yr for magnesium and 25 lb/A·yr for zinc.
Rectifier
A rectifier converts alternating current to direct current for impressed current cathodic protection. It uses a transformer and rectifier stack and allows output adjustment.
Coke breeze
Coke breeze is a conductive carbonaceous backfill around impressed-current anodes. It lowers groundbed resistance and helps distribute current uniformly around the anode.
MMO anode
Mixed metal oxide anodes are impressed-current anodes with a catalytic oxide coating on a titanium substrate. They are durable and commonly installed in coke breeze.
Groundbed resistance
Groundbed resistance is the resistance between the anode groundbed and the surrounding electrolyte. It largely determines rectifier voltage needed for a required CP current.
Stray current
Stray current is current flowing through unintended paths. Corrosion occurs where the current discharges from a metallic structure into the surrounding electrolyte.
Drainage bond
A drainage bond is a controlled electrical connection that diverts stray current from a structure to the current source or return path, reducing discharge and corrosion.
Current pickup
Current pickup is an area where stray current enters a structure, causing a negative potential shift. Corrosion risk is low at pickup and high at discharge areas.
Telluric current
Telluric currents are naturally occurring currents induced in the earth by geomagnetic activity. They cause fluctuating structure potentials and can interfere with CP surveys.
Cathodic disbondment
Cathodic disbondment is the loss of coating adhesion around a defect caused by cathodic reactions. It is worsened by excessive negative potentials and poor coating quality.
Coating holiday
A coating holiday is a breach or defect in a protective coating that exposes steel to electrolyte. CP current concentrates at holidays to protect the exposed metal.
Coating shielding
Coating shielding occurs when a disbonded coating blocks CP current from reaching the steel, allowing corrosion to continue beneath an apparently intact coating.
Fusion-bonded epoxy
Fusion-bonded epoxy is a thermoset pipeline coating applied as a powder and cured to form a tough dielectric barrier. It is commonly used with cathodic protection.
Lockout tagout
Lockout/tagout isolates hazardous energy before maintenance. For rectifiers, it requires switching off, locking the disconnect, and verifying absence of voltage.
Hydrogen evolution
Hydrogen evolution is the cathodic generation of hydrogen gas during cathodic protection. In confined spaces it creates a flammability hazard and requires ventilation and gas monitoring.
Rectifier troubleshooting
Rectifier troubleshooting checks AC supply, fuses, tap settings, DC output, polarity, groundbed resistance, and cable continuity to locate loss of protection current.
Confined space entry
Confined space entry requires atmospheric testing, ventilation, an attendant, and rescue provisions. CP work in vaults or tanks can expose workers to hydrogen and oxygen deficiency.