Direct antiglobulin test
DAT detects antibody or complement coating red cells in vivo; it is used to investigate hemolytic disease of the newborn, autoimmune hemolysis, and transfusion reactions.
Universal red cell donor
Group O donors lack A and B red cell antigens, so their red cells can be transfused to recipients of any ABO group; their plasma contains anti-A and anti-B.
Indirect antiglobulin test
The indirect antiglobulin test detects unexpected antibodies in patient serum after incubation with reagent red cells and antihuman globulin; it underlies the antibody screen and crossmatch.
Platelet storage conditions
Platelets are stored at 20-24 degrees Celsius with continuous gentle agitation for up to 5 days; refrigeration causes shape change and reduces post-transfusion viability.
Anion gap formula
Anion gap equals sodium minus the sum of chloride and bicarbonate; the reference range is 8-12 mEq/L, and an elevated gap suggests ketoacidosis, lactic acidosis, or toxin ingestion.
Friedewald LDL calculation
LDL cholesterol equals total cholesterol minus HDL minus triglycerides divided by 5; the calculation is invalid when triglycerides exceed 400 mg/dL and direct measurement is needed.
Corrected calcium formula
Corrected calcium equals measured calcium plus 0.8 times (4.0 minus albumin in g/dL); it adjusts for hypoalbuminemia because roughly half of serum calcium is protein bound.
Osmolal gap
The osmolal gap is measured osmolality minus calculated osmolality (2Na + glucose/18 + BUN/2.8); a gap above 10 suggests methanol, ethylene glycol, or isopropanol ingestion.
MCV calculation
MCV equals hematocrit divided by red cell count, multiplied by 10 and reported in femtoliters; it classifies anemia as microcytic, normocytic, or macrocytic.
Mixing study interpretation
A 1:1 mix of patient plasma and normal plasma that corrects a prolonged PT or aPTT indicates factor deficiency; failure to correct indicates a circulating inhibitor such as a lupus anticoagulant.
DIC laboratory pattern
Disseminated intravascular coagulation shows thrombocytopenia, prolonged PT and aPTT, low fibrinogen, and elevated D-dimer or fibrin degradation products with schistocytes on the smear.
Corrected reticulocyte count
Corrected reticulocyte count equals reticulocyte percent times (patient hematocrit divided by 45); a value below 2% suggests an inadequate marrow response to anemia.
Coagulase test
Coagulase converts fibrinogen to fibrin; Staphylococcus aureus is coagulase positive, which distinguishes it from coagulase-negative staphylococci such as Staphylococcus epidermidis.
Optochin sensitivity
Streptococcus pneumoniae is optochin sensitive and bile soluble, whereas viridans streptococci are optochin resistant and bile insoluble, allowing laboratory differentiation.
MacConkey agar
MacConkey agar selects for gram-negative bacilli and differentiates lactose fermenters, which form pink colonies, from nonfermenters, which remain colorless.
MRSA detection
Methicillin resistance in Staphylococcus aureus is mediated by mecA; it is detected by cefoxitin disk diffusion, oxacillin MIC testing, or polymerase chain reaction for mecA.
Primary versus secondary response
The primary immune response produces IgM first after a lag of days; re-exposure produces a faster, larger, IgG-predominant response with antibodies of higher affinity.
Hepatitis B serology
HBsAg indicates current infection, anti-HBs indicates immunity, IgM anti-HBc indicates acute infection, and HBeAg reflects high infectivity and active viral replication.
HIV testing algorithm
Fourth-generation screening assays detect HIV p24 antigen and antibody; reactive results are confirmed with an HIV-1/HIV-2 antibody differentiation immunoassay rather than Western blot.
Positive predictive value
Positive predictive value equals true positives divided by the sum of true positives and false positives; it increases as disease prevalence rises in the tested population.
Red cell casts
Red cell casts indicate glomerular bleeding, as occurs in glomerulonephritis; dysmorphic red cells and significant proteinuria further support a glomerular source of hematuria.
Struvite crystals
Struvite or triple phosphate crystals appear as coffin-lid shapes in alkaline urine and suggest infection with urease-producing bacteria such as Proteus species.
Light's criteria
Pleural fluid is classified as an exudate if the protein ratio exceeds 0.5, the LDH ratio exceeds 0.6, or fluid LDH exceeds two-thirds the upper normal serum value.
Synovial crystal birefringence
Monosodium urate crystals in gout are needle shaped and negatively birefringent; calcium pyrophosphate crystals in pseudogout are rhomboid and positively birefringent.
Real-time PCR cycle threshold
The cycle threshold is the cycle at which fluorescence first exceeds background; lower Ct values indicate a higher initial copy number of the target nucleic acid.
Sanger sequencing
Dideoxynucleotides terminate chain elongation during Sanger sequencing; fragments separated by capillary electrophoresis yield the sequence used to detect point mutations.
Factor V Leiden
A point mutation (R506Q) in the F5 gene causes activated protein C resistance and thrombophilia; testing uses polymerase chain reaction or a functional APC resistance assay.
No-template control
A no-template control contains all reagents except nucleic acid; amplification in this tube signals contamination and invalidates the entire polymerase chain reaction run.
Westgard 1-3s rule
A control value exceeding the mean by more than three standard deviations is a rejection rule that indicates random error, most often an imprecision problem.
Coefficient of variation
Coefficient of variation equals standard deviation divided by the mean, multiplied by 100; it expresses assay imprecision as a percentage and allows comparison between analytes.
Test sensitivity formula
Sensitivity equals true positives divided by the sum of true positives and false negatives; it is the proportion of patients with disease who are correctly identified.
Critical value reporting
A result in a life-threatening range must be reported promptly to the responsible caregiver, with documentation of read-back, time, and the name of the person notified.