AR Fire Alarm key terms
AR Fire Alarm · Get comfortable with the vocabulary.
- Initiating Device
- Related: Notification Appliance, Initiating Device Circuit
A system component such as a smoke detector, heat detector, manual pull station, or waterflow switch that automatically or manually sends a signal to the fire alarm control unit when fire or another emergency condition occurs.
- Notification Appliance
- Related: Notification Appliance Circuit, Initiating Device
An audible or visible device such as a horn, bell, chime, or strobe that alerts building occupants when the fire alarm system is activated. It is connected to a notification appliance circuit controlled by the panel.
- Initiating Device Circuit
- Related: Initiating Device, Addressable System
The wiring pathway connecting initiating devices to the fire alarm control unit. It may be conventional, where devices share an alarm state, or addressable, where each device reports individually.
- Notification Appliance Circuit
- Related: Notification Appliance, Supervision
The circuit that supplies power and signal to notification appliances. It is supervised by the control unit so that opens, shorts, or ground faults are annunciated as trouble conditions.
- Addressable System
- Related: Initiating Device Circuit, Addressable Device
A fire alarm arrangement in which each initiating or output device has a unique address, allowing the control unit to identify the specific device that activated or failed rather than only the circuit.
- Addressable Device
- Related: Addressable System, Signaling Line Circuit
A field device on an addressable system that carries its own unique identifier and communicates individually with the control unit over the signaling line circuit.
- Signaling Line Circuit
- Related: Addressable System, Supervision
The supervised pathway that carries digital communication between the fire alarm control unit and addressable devices. It may be wired as a loop or as a stub and is monitored for faults.
- Conventional System
- Related: Initiating Device Circuit, Zone
A fire alarm arrangement in which devices on a circuit are not individually identified; the control unit reports only the zone or circuit in alarm, and the general area must be searched to find the activated device.
- Zone
- Related: Conventional System, Annunciator
A defined area or group of devices that the fire alarm control unit reports as a single unit of alarm or trouble information. Zoning helps responders locate the general origin of a signal.
- Annunciator
- Related: Zone, Fire Alarm Control Unit
A remote display panel that shows alarm, supervisory, and trouble conditions by zone or device, typically installed at a main entrance or other location where responders can read system status.
- Fire Alarm Control Unit
- Related: Initiating Device, Notification Appliance
The central panel that receives signals from initiating devices, processes them, activates notification appliances and other outputs, monitors circuits for faults, and displays system status.
- Supervision
- Related: Trouble Signal, Signaling Line Circuit
Continuous electrical monitoring of a circuit or component so that a break, short, ground fault, or power loss is detected and reported as a trouble signal rather than going unnoticed.
- Trouble Signal
- Related: Supervision, Supervisory Signal
An audible and visual indication at the control unit that a fault exists in the system, such as an open circuit, loss of primary power, or failed device, meaning the system may not perform as designed.
- Supervisory Signal
- Related: Trouble Signal, Waterflow Switch
A signal indicating that a system or component being monitored, such as a sprinkler control valve or fire pump, has moved off its normal position or condition and needs attention but is not itself an alarm.
- Waterflow Switch
- Related: Supervisory Signal, Initiating Device
A device installed on a sprinkler system pipe that senses the movement of water caused by a flowing sprinkler head and sends an alarm signal to the fire alarm control unit.
- Smoke Detector
- Related: Initiating Device, Detector Spacing
A device that senses visible or invisible combustion products in the air and initiates an alarm signal. Common types include ionization, photoelectric, and air-sampling designs.
- Heat Detector
- Related: Initiating Device, Rate-of-Rise Detector
A device that responds to an abnormal rise in temperature or to a fixed high temperature and then initiates an alarm signal. It is generally slower to respond than a smoke detector.
- Rate-of-Rise Detector
- Related: Heat Detector, Fixed-Temperature Detector
A heat detector that activates when the temperature rises faster than a preset rate per minute, catching fast-growing fires before a fixed temperature threshold is reached.
- Fixed-Temperature Detector
- Related: Heat Detector, Rate-of-Rise Detector
A heat detector that activates when the surrounding temperature reaches a predetermined set point, regardless of how quickly that temperature was reached.
- Detector Spacing
- Related: Smoke Detector, Coverage Area
The maximum permitted distance between detectors and between detectors and walls, determined by the detector listing and the ceiling height and configuration, so coverage has no large gaps.
- Manual Pull Station
- Related: Initiating Device, Notification Appliance
A manually operated initiating device, typically mounted along an exit path, that a person actuates to send an alarm signal to the fire alarm control unit.
- Duct Detector
- Related: Smoke Detector, Initiating Device
A smoke detector installed in an HVAC duct that samples airflow and signals the alarm system, often also shutting down air handling to limit smoke spread through the building.
- Alarm Verification
- Related: Nuisance Alarm, Smoke Detector
A feature that briefly delays alarm processing to confirm that a smoke detector signal persists, reducing nuisance alarms from transient conditions such as dust or steam.
- Nuisance Alarm
- Related: Alarm Verification, Smoke Detector
An alarm caused by a condition that is not a real fire, such as cooking smoke, steam, or dust. Design, placement, and verification features are used to reduce these occurrences.
- Primary Power Supply
- Related: Secondary Power Supply, Battery Backup
The normal source of operating power for a fire alarm system, usually the commercial building electrical service, which must be dedicated and arranged so it is not easily disconnected.
- Secondary Power Supply
- Related: Primary Power Supply, Battery Backup
The standby source, typically rechargeable batteries or an engine-driven generator, that powers the fire alarm system when the primary supply fails, for a duration set by code.
- Battery Backup
- Related: Secondary Power Supply, Primary Power Supply
Rechargeable batteries within the control unit that carry the system load during a primary power outage and are sized to support standby plus alarm operation for the required period.
- Class A Circuit
- Related: Class B Circuit, Supervision
A circuit arranged so that an open or ground fault does not prevent the remaining devices from operating; the conductors leave the control unit and return on a separate path.
- Class B Circuit
- Related: Class A Circuit, Supervision
A circuit arranged so that a single open fault disables all devices beyond the break. It does not return to the control unit, and the fault is annunciated as a trouble condition.
- Ground Fault
- Related: Supervision, Trouble Signal
An unintended connection between a circuit conductor and earth or the enclosure. Fire alarm circuits are monitored so a ground fault is reported as a trouble condition.
- Voltage Drop
- Related: Notification Appliance Circuit, Ohm's Law
The loss of voltage along a conductor caused by its resistance as current flows. Notification circuits must be calculated so appliances still receive their rated voltage at the end of the circuit.
- Ohm's Law
- Related: Voltage Drop, Battery Backup
The relationship stating that voltage equals current multiplied by resistance. It is used to compute circuit current, voltage drop, and conductor sizing in fire alarm installations.
- Survivability
- Related: Class A Circuit, Signaling Line Circuit
The ability of critical fire alarm circuits to keep functioning during a fire, achieved through circuit integrity methods such as dedicated enclosures or fire-rated cable pathways.
- Inspection, Testing, and Maintenance
- Related: Supervision, Trouble Signal
The recurring program of visual inspection, functional testing, and servicing of fire alarm components at code-specified intervals to confirm the system remains operational and reliable.
- Acceptance Test
- Related: Inspection, Testing, and Maintenance, Record of Completion
The documented test performed after installation to demonstrate that the fire alarm system and its components operate as designed and meet the adopted code before the system is placed in service.
- Record of Completion
- Related: Acceptance Test, Inspection, Testing, and Maintenance
A document prepared at installation that records the system configuration, device locations, and test results, and that is kept available for future inspection and maintenance reference.
- Arkansas Fire Protection Licensing Board
- Related: Fire Protection Contractor License, Continuing Education
The state board responsible for licensing and regulating fire protection system contractors and technicians in Arkansas, including issuing licenses and enforcing the adopted rules.
- Fire Protection Contractor License
- Related: Arkansas Fire Protection Licensing Board, Permit
The credential an individual or business must hold to design, install, service, or inspect fire protection systems in Arkansas, obtained by meeting experience and examination requirements.
- Permit
- Related: Authority Having Jurisdiction, Acceptance Test
The official authorization issued by a local authority before fire alarm work begins, allowing installation or alteration and triggering required inspections before the system can be approved.
- Authority Having Jurisdiction
- Related: Permit, Acceptance Test
The organization, office, or individual responsible for approving equipment, installations, and procedures, and for interpreting and enforcing the fire and building codes in a given area.
- Continuing Education
- Related: Arkansas Fire Protection Licensing Board, Fire Protection Contractor License
Required ongoing training hours that Arkansas license holders must complete within each renewal cycle to maintain their fire protection credentials and stay current with codes and practices.