ARRT CT study materials
ARRT CT study resources

ARRT CT cheat sheet

ARRT CT · Keep the key ideas within reach.

Quick reference

Patient Care and Education

  • Informed consent for iodinated IV contrast documents allergy history, renal function (eGFR), prior contrast reactions, and the risk/benefit discussion before injection.

  • An eGFR of 30 mL/min/1.73 m² or higher is generally acceptable for iodinated contrast; values below 30 require radiologist risk/benefit review.

  • Metformin is withheld for 48 hours after iodinated contrast only when acute kidney injury or eGFR below 30 mL/min/1.73 m² is present, then resumed after renal function is rechecked.

  • Mild reactions (nausea, limited urticaria) are managed with observation and symptomatic treatment; anaphylactoid reactions (bronchospasm, laryngeal edema, hypotension) require IM epinephrine 1:1000, 0.3–0.5 mg in adults, oxygen, and IV fluids.

  • Extravasation response: stop the injection, remove the cannula, elevate the limb, apply a cold compress, document volume and site, and give follow-up instructions.

  • Breath-hold coaching: full inspiration for chest and abdomen; hyperventilating the patient before the hold lengthens achievable breath-hold time and reduces motion artifact.

  • Pregnancy is not an absolute contraindication to CT; the ACR position is that the study is performed when clinically indicated, with documented justification and shielding when feasible.

  • Warm flush, metallic taste, and transient nausea are expected during injection; the patient must report pain, burning, or swelling at the IV site immediately.

  • Pediatric care: lowest kVp and mAs consistent with diagnosis, weight-based contrast near 1–2 mL/kg, and immobilization preferred over sedation.

Quick reference

Imaging Procedures

  • Portal venous phase abdomen: approximately 60–70 seconds after start of injection at 3–5 mL/s; late arterial phase is approximately 35–40 seconds.

  • Bolus tracking: place the ROI in the target vessel, set a trigger near 100–150 HU, and begin the scan after the threshold plus a short post-trigger delay.

  • CT pulmonary angiogram: ROI in the pulmonary trunk with a threshold near 100 HU and a short post-threshold delay, or a timing test bolus.

  • CT urography excretory phase is acquired roughly 7–10 minutes after injection to opacify collecting systems and ureters.

  • Cardiac CT: target heart rate 60 bpm or below; prospective ECG-triggered step-and-shoot at 70–80% of the R-R interval lowers dose versus retrospective helical acquisition.

  • CT colonography requires bowel cleansing, CO2 insufflation to patient tolerance, and imaging supine and prone so stool and fluid redistribute.

  • Standard window settings: soft tissue W 350–400 / L 40–50; lung W ~1500 / L ~−600; bone W ~2000 / L 300–500; brain W ~80 / L ~40.

  • Restricting the scanned z-axis to the anatomy of interest and using automatic tube current modulation are the most reliable dose-reduction steps in routine protocols.

Quick reference

Physics and Instrumentation

  • HU = (μ_tissue − μ_water) ÷ μ_water × 1000; water is 0, air about −1000, and dense cortical bone 1000 or greater.

  • Helical pitch = table travel per gantry rotation ÷ total detector beam width; pitch above 1 lowers dose and raises noise, pitch below 1 raises dose.

  • CTDIvol = CTDIw ÷ pitch for helical scans; DLP = CTDIvol × scan length in cm; effective dose ≈ DLP × body-region k factor (mSv/mGy·cm).

  • Noise is inversely proportional to the square root of mAs: quadrupling mAs halves noise, and doubling mAs reduces it by roughly 30–40%.

  • Lowering kVp moves the beam nearer iodine's 33 keV k-edge, increasing iodine attenuation and contrast while raising noise, so mAs must rise to compensate.

  • The bowtie filter shapes the beam so fewer photons traverse the thin patient periphery, reducing surface dose and improving dose efficiency.

  • Spatial resolution improves with a small focal spot, thin slices, sharp high-frequency kernels, and small reconstructed pixel size; it is limited by detector aperture.

  • Beam hardening produces cupping and dark streaks between dense structures and is reduced by correction software, higher kVp, and thinner collimation.

  • Detector configuration (e.g., 64 × 0.625 mm) sets the minimum slice thickness and the total beam width used in the pitch calculation.