ARRT CT flashcards
ARRT CT · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Informed consent for contrast
- Obtained before iodinated IV contrast to document allergy history, renal function, prior reactions, and the risk/benefit discussion, allowing the patient to accept or refuse the injection.
- Metformin and iodinated contrast
- Hold metformin for 48 hours after contrast only when acute kidney injury or eGFR below 30 mL/min/1.73 m² is present; restart after renal function is rechecked.
- Extravasation first response
- Stop the injection immediately, remove the cannula, elevate the limb, apply a cold compress, and document the volume, site, and patient symptoms with follow-up instructions.
- Anaphylactoid reaction treatment
- Bronchospasm, laryngeal edema, or hypotension after contrast requires IM epinephrine 1:1000 at 0.3–0.5 mg in adults, plus oxygen, IV fluids, and emergency support.
- Breath-hold coaching
- Instruct the patient to take a full inspiration and hold still; having the patient hyperventilate beforehand lengthens the achievable breath-hold and reduces motion artifact.
- Pediatric CT dose principle
- Use the lowest kVp and mAs that produce a diagnostic image, weight-based contrast volumes near 1–2 mL/kg, and immobilization instead of sedation when possible.
- eGFR threshold for contrast
- An eGFR of 30 mL/min/1.73 m² or higher is generally acceptable for iodinated contrast; lower values require radiologist risk/benefit review and hydration planning.
- Expected contrast sensations
- A warm flush, metallic taste, and transient nausea are normal during injection; the patient should report pain, burning, or swelling at the IV site immediately.
- Pregnancy and CT
- CT is performed when clinically indicated regardless of pregnancy; justification is documented, shielding is used when feasible, and no single dose threshold defines fetal injury.
- IV cannula size for CTA
- Use a 20-gauge or larger cannula in an antecubital vein for flow rates of 4–5 mL/s; smaller or distal veins limit flow and degrade arterial opacification.
- Saline flush purpose
- A saline chaser after contrast pushes the column out of the tubing, reduces streak artifact from dense contrast in the right heart, and lowers total contrast volume needed.
- Portal venous phase timing
- Approximately 60–70 seconds after the start of IV contrast injection at 3–5 mL/s; hepatic and portal veins are opacified and liver parenchyma is enhanced.
- Late arterial phase
- About 35–40 seconds after injection, opacifying the hepatic artery and hypervascular tumors while portal vein enhancement remains incomplete.
- Bolus tracking technique
- Place a region of interest in a target vessel, set a trigger threshold near 100–150 HU, and start the scan after the threshold plus a short post-trigger delay.
- Excretory phase CT urography
- Imaging roughly 7–10 minutes after injection opacifies the renal collecting systems and ureters for evaluation of urothelial lesions or obstruction.
- Prospective cardiac gating
- Step-and-shoot acquisition triggered at 70–80% of the R-R interval lowers dose compared with retrospective helical scanning but requires a low, regular heart rate.
- CT colonography prerequisites
- Requires bowel cleansing, gas insufflation with CO2 to patient tolerance, and imaging in both supine and prone positions to redistribute stool and fluid.
- Lung window settings
- Window width about 1500 HU and window level about −600 HU display lung parenchyma; soft tissue windows would obscure fine interstitial detail.
- Brain window settings
- Window width about 80 HU and level about 40 HU; the narrow width maximizes gray-white differentiation in noncontrast head CT.
- Scan range reduction
- Restricting the scanned z-axis to the anatomy of interest is one of the most effective dose-reduction steps and does not degrade diagnostic image quality.
- Test bolus versus tracking
- A small test bolus measures time to peak enhancement before the main scan, while bolus tracking monitors enhancement in real time and triggers the scan automatically.
- Hounsfield unit formula
- HU = (μ_tissue − μ_water) ÷ μ_water × 1000, giving water a value of 0, air about −1000, and dense cortical bone 1000 or higher.
- Pitch definition
- Table travel per gantry rotation divided by the total detector beam width; pitch greater than 1 reduces dose but increases noise and slice broadening.
- CTDIvol and DLP
- CTDIvol equals CTDIw divided by pitch; DLP equals CTDIvol multiplied by scan length in centimeters, and effective dose is DLP times a body-region k factor.
- Noise versus mAs
- Image noise is inversely proportional to the square root of mAs, so quadrupling mAs halves noise while doubling mAs reduces it by about 30–40%.
- kVp and iodine contrast
- Lowering kVp moves the beam closer to iodine's 33 keV k-edge, increasing iodine attenuation and contrast while raising noise and requiring higher mAs.
- Bowtie filter function
- Shaping the beam so fewer photons pass through the thin patient periphery reduces surface dose and improves dose efficiency across the field of view.
- In-plane spatial resolution
- Best achieved with a small focal spot, thin slices, sharp high-frequency kernels, and small reconstructed pixel size; it is ultimately limited by detector aperture.
- Beam hardening artifact
- Appears as cupping or dark streaks between dense structures; it is reduced by beam-hardening correction software, higher kVp, and thinner collimation.
- Detector configuration and pitch
- A configuration such as 64 × 0.625 mm sets the minimum slice thickness and the total beam width that enters the pitch calculation.
- Photon starvation artifact
- Occurs when very few photons reach the detectors through thick body parts, producing horizontal streaks; tube current modulation and thicker slices reduce it.
- Ring artifact cause
- Caused by a miscalibrated or failed detector element that produces a circular ring centered on the rotation axis in every reconstructed slice.