Image Quality in Portable Chest

ARRT RRA · Put your knowledge to work in context.

All case studies

Image Quality in Portable Chest

A portable chest radiograph is ordered for a 55-year-old intubated patient in the ICU. The technologist uses a mobile unit with a computed radiography (CR) cassette. The image shows the endotracheal tube tip at the level of the clavicles, and the lungs are underexposed. The patient is on a ventilator and cannot be moved easily. The technologist is asked to repeat the image.

1. What positioning and technical adjustments should the technologist make for the repeat image?

Read the worked answer

Positioning: Ensure the cassette is centered at the level of the T7 vertebra (approximately 2-3 inches below the sternal angle) and the patient is as upright as possible (e.g., using a wedge). The tube should be angled slightly caudad to avoid clipping the costophrenic angles. Technical: Increase mAs to improve exposure (underexposure suggests insufficient mAs), use a higher kVp (100-120) to penetrate the mediastinum, and ensure the CR plate is properly processed. Use a grid if possible. Also, verify the endotracheal tube position and note that it appears too high (should be 3-5 cm above carina).

2. How can the technologist evaluate if the repeat image is adequate?

Read the worked answer

Evaluate: visualization of the entire lung fields, including costophrenic angles; adequate penetration (vertebrae visible behind the heart); no rotation (spinous processes centered between clavicles); endotracheal tube tip visible and ideally at least 3 cm above the carina; and proper inspiration (posterior ribs 9-10 visible). Also, check for artifacts and ensure patient identification.