ARRT RRA flashcards
ARRT RRA · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Normal adult respiratory rate
- 12 to 20 breaths per minute at rest. Rates outside this range, especially with distress or cyanosis, require assessment and notification of the radiologist before proceeding.
- Normal adult pulse range
- 60 to 100 beats per minute. Tachycardia with hypotension may indicate shock, while bradycardia may reflect medication effect or conduction abnormality.
- Signs of anaphylaxis
- Laryngeal edema, bronchospasm, hypotension, and urticaria occurring after contrast administration. Management includes epinephrine, oxygen, and IV fluids.
- Extravasation first response
- Stop the injection, remove the cannula, elevate the limb, apply a cold compress, and document volume and site. Monitor for swelling, pain, and compartment syndrome.
- Gadolinium contraindication threshold
- eGFR below 30 mL/min/1.73 m2 or dialysis dependence increases nephrogenic systemic fibrosis risk. Confirm renal function before administering gadolinium-based contrast.
- Metformin and iodinated contrast
- Hold metformin for 48 hours after contrast in patients with reduced renal function or acute kidney injury. Resume only after renal function is confirmed stable.
- Airborne precautions
- Used for tuberculosis, varicella, and measles. Requires a negative-pressure room and an N95 respirator for all entering personnel.
- Universal precautions principle
- Treat all blood and body fluids as infectious. Wear gloves for contact with nonintact skin or mucous membranes and perform hand hygiene before and after every patient.
- Vital sign monitoring during contrast
- Assess pulse, blood pressure, respiration, and skin status before and after contrast. Changes such as hypotension or dyspnea prompt immediate cessation and radiologist notification.
- Magnification factor formula
- Magnification factor equals SID divided by SOD, where SOD is source-to-object distance. Larger SID and smaller object-to-image distance reduce magnification.
- Grid ratio selection rule
- Use approximately 5:1 below 70 kVp, 8:1 for 70 to 90 kVp, and 10:1 to 12:1 above 90 kVp. Higher ratios require more precise centering and higher mAs.
- The 15 percent rule
- A 15 percent increase in kVp doubles receptor exposure, and a 15 percent decrease halves it. Compensate by halving or doubling mAs to maintain exposure.
- Automatic exposure control setup
- Select the chamber aligned with the anatomy of interest, center the part over that chamber, and set a backup time to prevent overexposure if the chamber fails.
- Fluoroscopy dose reduction
- Use pulsed fluoroscopy, last-image hold, minimal table-to-intensifier distance, and collimation. These measures apply the ALARA principle during fluoroscopic procedures.
- Power injector cannula gauge
- A 20 to 22 gauge cannula in a large antecubital vein is typical for power injection. Confirm blood return and patency with saline before contrast.
- Low-osmolar contrast advantage
- Nonionic low-osmolar agents cause less pain, nausea, and renal stress than high-osmolar ionic agents. They are preferred for intravenous administration.
- Iodinated contrast reaction categories
- Mild includes flushing and hives; moderate includes vomiting and bronchospasm; severe includes laryngeal edema, hypotension, and anaphylaxis requiring epinephrine.
- mA and exposure time
- Milliamperage multiplied by exposure time in seconds equals mAs. mAs controls receptor exposure and is the primary determinant of image noise.
- kVp and subject contrast
- Kilovoltage peak controls beam penetrability and subject contrast. Higher kVp lowers contrast and increases scatter; lower kVp raises contrast and patient dose.
- Patient positioning for chest radiography
- Upright PA at 72 inches SID with shoulders rolled forward and chin elevated. Full inspiration to 10 posterior ribs improves detection of subtle disease.
- Receptor exposure indicator
- A numeric value reflecting radiation reaching the digital receptor. Values outside the acceptable range indicate under- or overexposure and require technique correction.
- Quantum mottle cause
- Insufficient photons reaching the receptor produce grainy noise. Increasing mAs increases photon count and reduces quantum mottle in the image.
- Spatial resolution definition
- The ability to image small objects as separate structures, measured in line pairs per millimeter. Smaller focal spot and pixel size improve it.
- Anode heel effect
- Beam intensity is higher on the cathode side of the field. Position thicker anatomy toward the cathode to equalize receptor exposure across the image.
- Histogram left shift
- A histogram shifted toward lower values indicates underexposure and increased noise. Shifted right indicates overexposure and unnecessary patient dose.
- Contrast resolution definition
- The ability to distinguish tissues with similar attenuation. It improves with higher detector bit depth and lower image noise.
- Motion artifact appearance
- Blur or ghosting on the image caused by patient or equipment movement. Short exposure time and immobilization reduce its occurrence.
- Magnification in image evaluation
- Enlargement of the recorded image relative to the object. It increases with shorter SID and greater object-to-image-receptor distance.
- Shape distortion causes
- Elongation occurs when the object is angled relative to the beam; foreshortening occurs when the receptor is angled relative to the object. Alignment prevents both.
- Grid cutoff appearance
- Progressive loss of density toward the periphery of the image, caused by improper centering, wrong SID, or angulation with a focused grid.
- Focal spot size effect
- A smaller focal spot improves spatial resolution and recorded detail but limits tube current. Larger spots permit higher mA and shorter exposure times.
- Beam collimation purpose
- Restricting the field reduces patient dose and scatter and improves contrast. Collimation also defines the area of interest for evaluation.