ARRT RRA key terms
ARRT RRA · Get comfortable with the vocabulary.
- Informed consent
- Related: Patient identification, Advanced directive
A patient's voluntary agreement to a procedure after receiving an explanation of its purpose, risks, benefits, and alternatives. The radiographer confirms documentation exists but typically does not obtain consent for invasive procedures.
- Patient identification
- Related: Informed consent, Time-out
Verification that the correct patient is receiving the correct procedure, using at least two identifiers such as name and date of birth. It must be confirmed before every exam and before administering contrast or sedation.
- Time-out
- Related: Patient identification, Informed consent
A brief pause immediately before an invasive or high-risk procedure in which the team verbally confirms patient identity, procedure, site, and consent. It prevents wrong-patient and wrong-site errors.
- Advanced directive
- Related: Informed consent, Do-not-resuscitate order
A legal document stating a patient's wishes about medical treatment if they become unable to decide, including living wills and durable power of attorney. It guides care decisions during emergencies.
- Do-not-resuscitate order
- Related: Advanced directive, Cardiopulmonary arrest
A physician's written order that CPR should not be attempted if the patient's heart or breathing stops. The radiographer must recognize and honor it during a patient emergency.
- Cardiopulmonary arrest
- Related: Do-not-resuscitate order, Automated external defibrillator
Sudden loss of effective heart function and breathing, producing unresponsiveness and absent pulse. The radiographer calls for help, starts CPR, and retrieves the emergency cart and AED.
- Automated external defibrillator
- Related: Cardiopulmonary arrest
A portable device that analyzes a cardiac rhythm and delivers a shock to treat certain lethal arrhythmias. It is used with CPR during cardiac arrest while awaiting advanced care.
- Anaphylaxis
- Related: Contrast media reaction, Extravasation
A severe, rapidly progressing allergic reaction that can cause hives, airway swelling, wheezing, and dangerous drops in blood pressure. It is treated promptly with epinephrine and emergency support.
- Contrast media reaction
- Related: Anaphylaxis, Extravasation
An adverse response to iodinated or other contrast material ranging from mild nausea or hives to severe breathing difficulty and shock. Prompt recognition and treatment determine the outcome.
- Extravasation
- Related: Contrast media reaction, Venipuncture
Leakage of injected contrast or medication out of a vein into surrounding tissue, causing pain, swelling, and possible tissue damage. The injection is stopped and the area is assessed and documented.
- Venipuncture
- Related: Extravasation
Puncture of a vein to place a needle or catheter for injecting contrast or drawing blood. Correct technique, site selection, and aseptic practice reduce complications.
- Vital signs
- Related: Pulse oximetry, Orthostatic hypotension
Measurements of temperature, pulse, respiration, blood pressure, and oxygen saturation that reflect a patient's physiologic status. They are monitored before, during, and after procedures when indicated.
- Pulse oximetry
- Related: Vital signs
A noninvasive method using light sensors on the finger or ear to estimate the percentage of hemoglobin saturated with oxygen. It helps detect hypoxemia during sedation or respiratory compromise.
- Orthostatic hypotension
- Related: Vital signs, Patient fall prevention
A drop in blood pressure when a patient moves from lying to sitting or standing, causing dizziness or fainting. It is a fall risk after prolonged supine positioning or dehydration.
- Patient fall prevention
- Related: Orthostatic hypotension, Patient transfer
Measures such as lowering the table, using side rails, assisting ambulation, and keeping call buttons within reach to stop patients from falling. Falls are a common and preventable imaging department injury.
- Patient transfer
- Related: Patient fall prevention
Moving a patient safely between a wheelchair, stretcher, and imaging table using proper body mechanics and adequate help. It protects both the patient and the radiographer from injury.
- Medical asepsis
- Related: Standard precautions, Surgical asepsis
Practices that reduce the number and spread of microorganisms, including hand hygiene and clean technique. It applies to routine patient contact and equipment handling in imaging areas.
- Standard precautions
- Related: Medical asepsis, Surgical asepsis
Infection-control practices applied to all patients, including hand hygiene, gloves, and barriers when contact with blood or body fluids is likely. They assume any body fluid may be infectious.
- Surgical asepsis
- Related: Standard precautions, Medical asepsis
Techniques that keep an area and objects completely free of microorganisms, used for invasive procedures such as catheter placement or sterile field setup. Sterile technique differs from routine clean practice.
- Immobilization
- Related: Motion artifact, Radiographic positioning
Use of devices such as sandbags, tape, or positioning aids to hold a patient still and maintain the required position. It reduces motion artifact and improves image quality.
- Radiographic positioning
- Related: Immobilization, Central ray, Anatomical position
Placing the patient and adjusting the tube and detector to demonstrate the required anatomy in a specific projection. Accurate positioning is essential for diagnostic images and radiation protection.
- Anatomical position
- Related: Radiographic positioning
The reference posture with the body upright, facing forward, arms at the sides, and palms forward. Positional terminology such as medial, lateral, and proximal is based on it.
- Central ray
- Related: Radiographic positioning, Beam alignment
The central portion of the x-ray beam, directed to a specific point on the patient and used to align the part with the detector. Correct centering reduces distortion and improves image quality.
- Beam alignment
- Related: Central ray, Distortion
Orienting the x-ray beam perpendicular to the image receptor and centered on the anatomy of interest. Misalignment produces distortion and uneven exposure across the image.
- SID
- Related: Magnification, Beam alignment
Source-to-image receptor distance: the distance from the focal spot to the image receptor. It affects magnification and exposure, and is standardized for many exams to keep images consistent.
- Magnification
- Related: SID, Distortion
Enlargement of the imaged anatomy caused by divergence of the x-ray beam. It increases when the object is farther from the receptor or the source is closer to the object.
- Distortion
- Related: Beam alignment, Magnification
Misrepresentation of the true shape or size of anatomy on an image, caused by improper alignment, angulation, or object-receptor distance. It can make structures appear elongated or foreshortened.
- Motion artifact
- Related: Immobilization
Blurring or double images caused by patient, tube, or receptor movement during exposure. It is reduced by short exposure times, clear instructions, and immobilization.
- Grid
- Related: Scatter radiation, Grid cutoff
A device of lead strips that absorbs scattered radiation before it reaches the image receptor, improving contrast. It is used with thicker body parts and requires correct distance and centering.
- Grid cutoff
- Related: Grid
Loss of density across an image caused by improper grid use, such as wrong distance, off-center tube, or tube angulation. It appears as a gradual or sharp decrease in brightness.
- Scatter radiation
- Related: Grid, Collimation
X-rays that have been deflected and changed in direction within the patient, adding unwanted exposure and reducing image contrast. It is controlled with collimation, grids, and proper technique.
- Collimation
- Related: Scatter radiation
Restricting the x-ray beam to the area of interest with adjustable shutters. It reduces patient dose and scatter and improves image contrast.
- Radiographic density
- Related: Contrast, Exposure indicator
The overall degree of blackening on a radiograph, controlled mainly by mAs. In digital imaging it relates to the amount of signal reaching the receptor.
- Contrast
- Related: Radiographic density, Scatter radiation
The visible difference in brightness between adjacent areas of an image, affected by subject contrast, kVp, and scatter. Higher contrast shows fewer gray tones and sharper differences.
- Exposure indicator
- Related: Radiographic density, ALARA
A numeric value displayed by digital systems that estimates how much radiation reached the receptor. It guides technique adjustment but is not a direct measure of patient dose.
- ALARA
- Related: Exposure indicator, Collimation
As Low As Reasonably Achievable: the principle of minimizing radiation dose to patients and staff while obtaining needed diagnostic information. It guides technique selection and shielding decisions.
- Image artifact
- Related: Motion artifact
Any unwanted feature on an image that does not represent the patient's anatomy, such as scratches, clothing, or processing errors. Recognizing artifacts prevents misinterpretation.
- Image evaluation
- Related: Image artifact, Radiographic positioning
Systematic review of an image for positioning, exposure, contrast, artifacts, and demonstration of required anatomy before accepting it. It determines whether a repeat exposure is needed.