ASE S7 Air Conditioning Systems & Controls (School Bus) study materials
ASE S7 Air Conditioning Systems & Controls (School Bus) study resources

ASE S7 Air Conditioning Systems & Controls (School Bus) cheat sheet

ASE S7 Air Conditioning Systems & Controls (School Bus) · Keep the key ideas within reach.

Quick reference

A/C System Inspection, Diagnosis, and Repair

  • Static pressure with system off at 80°F ambient: roughly 70-90 psig on both high and low sides when properly charged.

  • Low side too high and high side too low together indicate a weak or worn compressor, not a charge problem.

  • Both gauges low with bubbles in the sight glass indicate an undercharge; both high with no subcooling indicate an overcharge.

  • Temperature differential across the evaporator coil of 15-25°F is normal; below 10°F suggests low refrigerant or restricted airflow.

  • A sweating or frosted suction line at the expansion valve outlet points to an overcharge or a stuck-open expansion valve.

  • Pressure test for leaks with dry nitrogen plus trace refrigerant; electronic leak detectors find leaks down to about 0.1 oz/yr.

  • Performance test: vent temperature 35-45°F below ambient at 1,500-1,800 engine rpm with blower on high and doors open.

  • Manifold gauge set hoses: blue to low side, red to high side, yellow to vacuum pump or recovery machine.

Quick reference

Refrigerant Recovery, Recycling, and Handling

  • Section 609 of the Clean Air Act prohibits venting refrigerant to the atmosphere and requires certified technicians for motor vehicle A/C service.

  • Recovery cylinders must never be filled above 80% of gross weight capacity; use a scale, not the float gauge alone.

  • Recovered refrigerant may be recycled on site but not reused in a different customer's vehicle unless it meets SAE J2788 purity.

  • R-134a recovered refrigerant must be identified by the SAE J1990 or J2788 machine's oil separation and filter-drier stages.

  • Never mix R-12 and R-134a; contaminated mixtures must be destroyed, not recycled.

  • Evacuation to 500 microns (29.9 inHg) and holding for 10 minutes confirms a leak-free, moisture-free system.

  • Recovery cylinder must be DOT-approved, gray with a yellow top for R-134a, and never filled by liquid without a scale.

  • Refrigerant contact with skin causes frostbite; wear gloves and eye protection and ventilate the work area.

Quick reference

Compressor and Drive Systems

  • Compressor clutch coil resistance is typically 3-5 ohms; infinite resistance indicates an open coil.

  • Clutch air gap specification is usually 0.014-0.030 in (0.35-0.75 mm); excessive gap prevents engagement.

  • A seized compressor may shear the drive belt or slip the clutch; check for a locked-up clutch hub before condemning.

  • Compressor oil is PAG (polyalkylene glycol) for R-134a; never use mineral oil in an R-134a system.

  • Oil charge is typically 4-8 oz total; adding oil requires draining and measuring from the removed component.

  • Low suction and high discharge together with a hot clutch indicate internal compressor wear or a restricted discharge line.

  • Noise on engagement that stops when the clutch disengages points to clutch bearing or pulley misalignment.

  • System must have a low-pressure cutoff switch to protect the compressor from running with low refrigerant.

Quick reference

Condenser, Evaporator, and Refrigerant Lines

  • Condenser must have unobstructed airflow; a clogged condenser raises high-side pressure and reduces cooling.

  • High-side pressure above 2.5 times ambient plus 30 psig indicates condenser airflow restriction or overcharge.

  • Evaporator coil must be clean and drain pan clear; a clogged evaporator drain causes water on the floor and fogging.

  • Suction line should be insulated from the evaporator outlet to the compressor to prevent condensation and heat gain.

  • Liquid line restriction shows as a temperature drop across the restriction; frost at the orifice confirms it.

  • Line fittings use O-rings compatible with R-134a; lubricate O-rings with PAG oil, never with mineral oil.

  • Evaporator inlet and outlet temperature difference of 15-25°F indicates proper refrigerant flow; less than 10°F suggests low charge.

  • A/C hoses are barrier-type for R-134a; standard R-12 hoses leak R-134a through the wall.

Quick reference

Expansion Devices and Refrigerant Flow Control

  • TXV controls superheat at the evaporator outlet; typical superheat is 5-10°F.

  • A stuck-open TXV floods the evaporator, causing low superheat, sweating suction line, and possible compressor slugging.

  • A stuck-closed TXV starves the evaporator, causing low suction pressure and no cooling.

  • Orifice tube systems use an accumulator with a desiccant bag and a fixed orifice; TXV systems use a receiver-drier.

  • TXV sensing bulb must be tightly clamped to the suction line and insulated; loose bulb causes hunting.

  • Superheat = evaporator outlet temperature minus evaporator saturation temperature at suction pressure.

  • Subcooling = liquid line temperature subtracted from condenser saturation temperature; 10-15°F indicates a full charge.

  • Orifice tube color codes identify size; wrong tube causes incorrect flow and pressure imbalance.

Quick reference

Electrical and Electronic Controls

  • Blower motor resistor pack uses series resistors to provide low, medium, and high speeds; an open resistor kills lower speeds only.

  • Blower motor draws high current; a seized motor blows the fuse or the resistor.

  • A/C pressure switch opens the compressor clutch circuit on low or high pressure to protect the system.

  • Ambient temperature switch prevents compressor operation below about 32-40°F to avoid evaporator freeze-up.

  • Clutch relay coil is controlled by the PCM or HVAC control head; check for 12V at the coil and ground at the control side.

  • Blower motor current draw is typically 10-20 amps on high; higher indicates a dragging motor.

  • Use a wiring diagram to trace the clutch circuit; a blown fuse may indicate a shorted clutch coil or pinched wire.

  • HVAC control head uses a blend door actuator and mode door actuator; a failed actuator causes temperature or mode faults.

Quick reference

HVAC Air Distribution and Blower Systems

  • Blower motor resistor pack provides low, medium, and high speeds; high speed often bypasses the resistor.

  • Cabin air filter restricts airflow when clogged; replace per manufacturer interval, typically 15,000-30,000 miles.

  • Mode door directs air to floor, panel, or defrost; a failed actuator leaves air stuck in one mode.

  • Blend door mixes hot and cold air; a stuck blend door causes no temperature control.

  • Airflow restriction at the evaporator causes low cooling and possible evaporator freeze-up.

  • Blower motor must be checked for free rotation; a dragging motor draws excessive current and can melt the connector.

  • Recirculation door position affects cooling performance; recirculation mode improves cooling in high ambient.

  • Defrost mode uses A/C to dehumidify; the compressor runs in defrost to clear the windshield.

Quick reference

Heating and Defrost Systems

  • Heater core uses engine coolant; a clogged core causes poor heat and unequal inlet/outlet temperatures.

  • Blend door actuator controls heater core flow through the air box; a failed actuator gives no heat or full heat.

  • Defrost performance requires the A/C compressor to run to dehumidify the air; a failed compressor causes fogging.

  • Heater control valve regulates coolant flow to the core; a stuck-closed valve causes no heat.

  • Coolant level and thermostat affect heater output; a stuck-open thermostat causes low heat.

  • Defroster door directs air to the windshield; a failed mode door leaves air at the floor.

  • Heater core leak shows as coolant smell in the cabin and fogging on the windshield.

  • Rear heater systems on school buses use a separate blower and core; check both for heat output.

Quick reference

Safety, Environmental, and Regulatory Compliance

  • Section 609 certification is required to service motor vehicle A/C systems; Section 608 covers stationary equipment.

  • Venting refrigerant to the atmosphere is illegal; recovery is required before opening the system.

  • R-134a is a greenhouse gas; use recovery equipment and never release it to the atmosphere.

  • Wear safety glasses and gloves; liquid refrigerant causes frostbite and eye damage.

  • Recovery cylinders must be DOT-approved and never overfilled beyond 80% capacity.

  • Work in a ventilated area; refrigerant displaces oxygen and can cause asphyxiation in enclosed spaces.

  • Refrigerant containers must be stored upright and away from heat sources; never heat with an open flame.

  • Used refrigerant oil must be disposed of per local regulations; never pour it down a drain.