ASE T7 HVAC (Medium/Heavy Truck) study materials
ASE T7 HVAC (Medium/Heavy Truck) study resources

ASE T7 HVAC (Medium/Heavy Truck) flashcards

ASE T7 HVAC (Medium/Heavy Truck) · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Compressor function
Pumps refrigerant vapor from the low-pressure evaporator side to the high-pressure condenser side, raising its temperature above ambient so heat can be rejected.
Condenser role
Rejects heat absorbed by the evaporator plus compressor work, condensing high-pressure vapor into liquid before it reaches the receiver-drier or accumulator.
Accumulator purpose
Located on the evaporator outlet in orifice-tube systems, it stores excess liquid refrigerant, holds desiccant, and prevents liquid slugging of the compressor.
Receiver-drier purpose
Mounted on the condenser outlet in TXV systems, it stores liquid refrigerant, removes moisture with desiccant, and provides a sight glass for charge checks.
TXV function
Thermostatic expansion valve meters refrigerant into the evaporator and modulates flow to maintain a set superheat at the evaporator outlet.
Orifice tube operation
A fixed restriction that meters refrigerant flow; system charge and accumulator design control performance because the tube cannot adjust to load.
Blower resistor function
Drops voltage to the blower motor in steps to provide lower speeds; failure typically leaves only high-speed operation or no blower at all.
Static pressure rule
With the system off and stabilized, gauge pressure approximates refrigerant saturation pressure at ambient temperature, about 70 psi for R-134a at 70°F.
Low charge symptoms
Both gauges read below normal, cooling is poor, and the compressor may cycle rapidly; bubbles may appear in the sight glass on TXV systems.
Overcharge symptoms
Both high and low side pressures are above normal with reduced cooling; high discharge pressure and possible clutch cycling from high-pressure cutoff.
Superheat formula
Superheat equals evaporator outlet temperature minus evaporator saturation temperature; normal TXV superheat is roughly 5 to 10°F.
Subcooling formula
Subcooling equals condenser saturation temperature minus liquid line temperature; low subcooling with bubbles indicates undercharge or a restriction.
Restriction indicator
A temperature drop across a component, such as a frosted orifice tube or cold suction line section, signals a restriction in that area.
Evacuation target
Pull the system to 500 microns or lower and hold with the pump isolated; a rising vacuum indicates a leak or residual moisture.
Leak detection methods
Electronic leak detectors, UV dye with black light, and soap solution locate leaks; never braze or weld on a charged system.
No heat diagnosis
If both heater hoses are hot but the cabin is cold, suspect the blend door, actuator, or control head rather than coolant flow.
Heater core restriction
A large temperature difference between heater core inlet and outlet hoses with poor cabin heat indicates restricted coolant flow through the core.
Blend door function
An air door that proportions airflow through the heater core and evaporator to set cabin temperature; actuator or calibration faults cause temperature errors.
Cabin air filter effect
A clogged filter reduces airflow across the evaporator and heater core, causing weak cooling and heating that mimics refrigerant or blower faults.
Evaporator freeze-up
Ice forms on the evaporator when the temperature sensor or cycling switch fails, blocking airflow and causing cooling to fade after extended operation.
Fan clutch effect
A slipping fan clutch reduces airflow through the condenser and radiator, raising discharge pressure and degrading A/C performance at idle.
Thermostat and heat
A thermostat stuck open keeps engine coolant too cool, reducing heater output; verify engine operating temperature before diagnosing the HVAC system.
Clutch control circuit
Compressor clutch may be driven directly, through a relay, or by a module; verify coil power, ground, and command before replacing the clutch.
High-pressure cutoff
A switch or sensor that disengages the compressor clutch when discharge pressure exceeds a set limit, protecting the system from overpressure damage.
Low-pressure cutoff
Disengages the compressor when suction pressure falls too low, preventing operation with an undercharge or at low ambient temperatures.
PWM blower module
Receives a duty-cycle command from the control head and varies blower motor speed; check command signal and grounds before replacing the motor.
Actuator feedback code
An out-of-range door position code often indicates a stuck door or failed actuator rather than a faulty control module.
CAN communication loss
Loss of module communication on the bus can disable blower, blend, and compressor functions; check network codes before component replacement.
Voltage drop testing
Measuring voltage lost across a circuit under load reveals high resistance; even 0.5V on a ground can cause intermittent blower or clutch operation.
Recovery requirement
Refrigerant must be recovered before opening the system; venting to atmosphere is prohibited and requires EPA Section 609 certified equipment and technicians.
Cylinder fill limit
Recovery cylinders must never be filled above 80 percent capacity and must carry a current hydrostatic test date and proper labeling.
Refrigerant safety
Liquid refrigerant causes frostbite, and vapor displaces oxygen in enclosed spaces; wear gloves and eye protection and ventilate the work area.