ACI study materials
ACI study resources

ACI cheat sheet

ACI · Keep the key ideas within reach.

Quick reference

Concrete Materials and Mixture Proportions

  • Water-cementitious materials ratio (w/cm) governs strength and durability; lower w/cm yields higher strength and lower permeability, with practical minimums near 0.40 for severe exposure.

  • Abrams' rule: strength is inversely related to w/c; a common approximation is fc' ≈ A/B^(w/c), so small w/c changes produce large strength changes.

  • Absolute volume method: V_aggregate = 1 m³ (or 1 yd³) minus volumes of water, cement, and air; aggregate volume is derived, not assumed.

  • Entrained air (typically 4–8%) improves freeze-thaw resistance; air content increases with maximum aggregate size decreasing and with exposure severity.

  • Supplementary cementitious materials: fly ash and slag reduce early strength but improve long-term strength, permeability, and sulfate resistance; silica fume greatly increases strength and reduces permeability.

  • Nominal maximum aggregate size should be the largest that permits adequate workability; it is limited by member dimensions (commonly ≤ 1/5 of narrowest dimension) and by clear spacing between reinforcement.

  • Slump is a workability indicator only; it does not measure placeability, and high-slump mixtures may segregate unless cohesion is controlled through paste content and grading.

  • Mixture proportioning starts from target mean strength (fc' plus margin for variability), then selects w/cm, air content, and water content, and finally computes cement and aggregate quantities.

Quick reference

Concrete Batching, Mixing, and Delivery

  • Batching tolerances: cementitious materials commonly ±1% of required mass; aggregates ±2%; water ±1%; admixtures ±3% (per ACI 304 guidance).

  • Moisture content of aggregates must be measured and free water subtracted from the batch water to maintain the specified w/cm.

  • Mixing time after all materials are in the drum is typically a minimum of 60–90 seconds for stationary mixers; truck mixers commonly require 70–100 revolutions at mixing speed.

  • Delivery: concrete should be discharged within 90 minutes of batching (or before 300 revolutions) unless a longer time is approved based on slump and temperature testing.

  • Truck mixer agitation speed is about 2–6 rpm; mixing speed is higher (typically 8–12 rpm). Adding water at the jobsite is permitted only within specified limits and with records.

  • Ready-mix tickets must record batch time, mix design, quantities, water added, revolutions, and discharge times; these are the primary delivery quality records.

  • Volumetric (mobile) mixers allow on-site proportioning and must be calibrated; mix proportions are verified by yield checks.

  • Concrete temperature at placement commonly should be between 5 °C and 35 °C (40–95 °F); hot-weather limits are often 32 °C (90 °F) or lower.

Quick reference

Concrete Placement and Consolidation

  • Free fall of concrete should generally not exceed 1.0–1.5 m (3–5 ft); use drop pipes or chutes to prevent segregation.

  • Place concrete in horizontal layers of limited thickness (commonly 300–600 mm) and consolidate each layer before placing the next.

  • Internal vibrators should penetrate the previous layer about 100–150 mm (4–6 in) to knit layers together; avoid over-vibration, which causes segregation.

  • Vibration is complete when the surface becomes relatively smooth, air bubbles diminish, and the concrete begins to level; typically 5–15 seconds per insertion point.

  • Vibrator spacing should be about 1.5 times the radius of action (commonly 450–600 mm); withdraw slowly to allow the hole to close.

  • Never use vibration to move concrete laterally; use hand shovels or chutes to reposition, since flowing with a vibrator causes segregation.

  • Placement in cold weather requires protection from freezing until the concrete attains sufficient strength (commonly 3.5 MPa or more) and maintaining temperature above 5 °C.

  • Pumping requires a well-graded, cohesive mix; excessive coarse aggregate or low fines causes blockages, so pump mixes often have higher sand content and adequate paste.

Quick reference

Finishing, Curing, and Protection

  • Do not finish concrete while bleed water is present on the surface; finishing too early causes a weak, dusty surface layer.

  • Bull floating or darbying should follow initial screeding; troweling should begin only after the surface has stiffened and bleed water has disappeared.

  • Curing must begin as soon as the concrete is finished and kept continuously moist; the curing period commonly is 7 days for normal concrete and 3 days for high-early-strength.

  • Curing methods include ponding, wet burlap, plastic sheeting, curing compounds, and formwork retention; curing compounds must be applied to a moist surface and form a continuous film.

  • Evaporation rate above about 1 kg/m²/h (0.2 lb/ft²/h) requires fogging, windbreaks, or evaporation retarders to prevent plastic shrinkage cracking.

  • Cold-weather protection: maintain concrete above 5 °C (40 °F) until it reaches about 3.5 MPa strength; use insulating blankets, heaters, or enclosures.

  • Hot-weather precautions include cooling aggregates and water, using ice, shading, and scheduling placement during cooler hours to limit concrete temperature.

  • Jointing: control joints should be cut or formed to about 1/4 of slab thickness and spaced so that panels are approximately square; saw cutting should occur as soon as concrete can support the saw without raveling.

Quick reference

Inspection, Testing, and Quality Control

  • Slump test measures consistency; typical tolerances are ±25 mm (1 in) for specified slump up to 100 mm, and ±40 mm (1.5 in) for greater slumps.

  • Air content by pressure meter or volumetric method; typical tolerance is ±1.5% for air-entrained concrete.

  • Compressive strength test: standard 150 × 300 mm cylinders (or 100 × 200 mm) cured under standard conditions and tested at 28 days; the average of two cylinders is a test result.

  • Acceptance criteria (ACI 318): no single strength test below fc' − 3.5 MPa (500 psi), and the average of three consecutive tests ≥ fc'.

  • Temperature test: measure concrete temperature at placement; commonly must be 10–32 °C (50–90 °F) depending on specification.

  • Sampling frequency commonly requires one set of strength specimens per 110 m³ (150 yd³) or per day of placement, whichever is more frequent.

  • Cylinders must be molded in layers (2 layers for 100×200 mm, 3 layers for 150×300 mm), rodded or vibrated per standard, and capped before testing.

  • Quality control includes verifying batch weights, moisture corrections, yield, and slump/air at the point of discharge; statistical evaluation uses standard deviation to determine required average strength.

Quick reference

Safety, Standards, and Specifications

  • ACI 318 is the building code requirements for structural concrete, covering design, materials, and construction requirements; ACI 301 covers specifications for structural concrete.

  • ACI 304 covers measuring, mixing, transporting, and placing; ACI 305 covers hot-weather concreting; ACI 306 covers cold-weather concreting.

  • ACI 308 covers curing; ACI 302 covers construction of floor slabs; ACI 117 covers tolerances.

  • Personal protective equipment for concrete work includes hard hat, safety glasses, gloves, boots, and respiratory protection for silica dust; wet concrete is alkaline and can cause chemical burns.

  • Silica exposure control: cutting, grinding, and drilling concrete require wet methods or local exhaust ventilation and respiratory protection per OSHA 29 CFR 1926.1153.

  • Formwork and shoring must be designed for loads including concrete weight, construction loads, and impact; reshoring is required until members can support themselves.

  • Fall protection is required at elevations of 1.8 m (6 ft) or more in general construction; guardrails, nets, or personal fall arrest systems must be used.

  • Lockout/tagout applies to mixers, conveyors, and pumps; never reach into a mixer drum or hopper while equipment is energized.