ASNT NDT Level II · Keep the key ideas within reach.

Quick reference

Electromagnetic Testing (ET)

  • Skin depth δ = 1/√(π f μ σ); it decreases as frequency, conductivity, or permeability increases, and increases with resistivity.

  • Approximate field/density at depth: 1δ retains about 37% of surface density, 2δ about 14%, 3δ about 5%.

  • Lower test frequency penetrates deeper but lowers resolution; raise frequency when only surface and near-surface defects matter.

  • The impedance plane plots resistance against inductive reactance; defect depth is read from phase angle, while amplitude alone is unreliable.

  • Fill factor = (coil inside area − part area) / coil inside area; a higher fill factor concentrates the field and raises sensitivity on small-diameter parts.

  • Lift-off shifts the signal mainly along one impedance-plane direction; hold it constant or use phase rotation to null it out.

  • Ferromagnetic materials restrict ET to surface and near-surface inspection because permeability dominates; remote field testing is used for ferromagnetic tubing.

  • Reference standards must match the part's alloy, temper, and heat treatment, because conductivity and permeability control the eddy current response.

Quick reference

Magnetic Particle Testing (MT)

  • Detection is best when the magnetic field is roughly perpendicular to the defect; a defect parallel to the flux produces little particle accumulation.

  • Circular magnetization (prod, central conductor, contact) finds longitudinal defects; longitudinal magnetization (coil, head shot) finds circumferential defects.

  • Coil magnetization current: I = 45,000 / (L/D) amperes, valid for parts with L/D of 3 or more; low L/D parts self-demagnetize and need more current.

  • Prod spacing is typically 3–8 in (75–200 mm) with about 100 A per inch of spacing (commonly 90–125 A/in).

  • The continuous method (current on while particles are applied) is more sensitive than the residual method, which requires a material with high retentivity.

  • Demagnetize after testing whenever residual magnetism could affect machining, welding, or service; use a reversing field of decreasing amplitude.

  • Fluorescent MT requires a minimum black light intensity of about 1000 µW/cm² at the inspection surface, about 5 min dark adaptation, and a darkened area.

  • Wet fluorescent particles in suspension give the best sensitivity for fine defects; dry powder suits high-temperature work and rough castings.

  • Scale, oil, and coatings can bridge or trap particles and produce false or missed indications, so surfaces are cleaned before magnetization.

Quick reference

Liquid Penetrant Testing (PT)

  • Standard sequence: pre-clean, apply penetrant and dwell, remove excess, dry, apply developer and dwell, inspect, post-clean.

  • Penetrant dwell is typically 10–15 min and developer dwell 10–30 min; tight or shallow discontinuities need the longer times.

  • Standard penetrant testing is limited to surface temperatures of 50–125 °F (10–52 °C); outside that range special penetrants or qualification are required.

  • Type I penetrant is fluorescent and needs black light; Type II is visible and needs adequate white light; sensitivity levels run 1/2 through 4.

  • Methods are A (solvent removable), B (water washable), C (post-emulsifiable, lipophilic), and D (post-emulsifiable, hydrophilic).

  • Water-washable penetrants require a water-tolerance test; post-emulsifiable systems are preferred on rough or as-cast surfaces.

  • Over-washing leaches penetrant from discontinuities and produces faint or missed indications, so wash time and pressure must be controlled.

  • Developer forms a thin uniform film, draws penetrant out of the discontinuity by capillarity, and increases visible contrast.

  • Blasting, grinding, or machining can smear or peen metal over discontinuities and mask them; chemical cleaning is preferred before PT.

Quick reference

Radiographic Testing (RT)

  • Geometric unsharpness Ug = F·t/d, where F is source size, t is object-to-film distance, and d is source-to-object distance; reduce it with a smaller source or larger d.

  • Attenuation follows I = I0 e^(−μx); the half-value layer halves intensity and the tenth-value layer reduces it to one tenth.

  • Inverse square law: intensity varies as 1/d², so doubling source-to-film distance requires about four times the exposure.

  • Typical acceptable film density is 1.8–4.0; density below the code minimum reduces contrast and requires re-radiography.

  • A source-side IQI (penetrameter) gives the required sensitivity; film-side placement demands a smaller, harder-to-see IQI for the same sensitivity.

  • Ir-192 has a 74-day half-life and serves steel about 0.5–3 in thick; Co-60 covers thicker sections; Se-75 and Yb-169 suit thinner material.

  • Lead intensifying screens cut exposure time and filter low-energy scatter, while fluorescent screens trade image resolution for speed.

  • Scatter control: collimate the beam, mask the part, back the cassette with lead, and use a backscatter shield checked with the Pb 'B' test.

  • Film processing time, temperature, and chemistry must be controlled, or density and contrast are not reproducible between exposures.

Quick reference

Ultrasonic Testing (UT)

  • Wavelength λ = c/f; higher frequency gives shorter wavelength, better resolution and sensitivity, but greater attenuation.

  • Acoustic impedance Z = ρc, and the reflection coefficient at normal incidence is R = (Z2 − Z1)/(Z2 + Z1).

  • Near field length N = D²f/(4c); flaw sizing and evaluation are normally performed beyond N, where the beam is more uniform.

  • Beam divergence half-angle for a circular transducer: sin θ = 1.22 λ/D; larger diameter and higher frequency reduce spread.

  • Snell's law sin θ1/c1 = sin θ2/c2 sets the wedge angle; the first critical angle eliminates refracted longitudinal waves and the second eliminates shear waves.

  • Common refracted shear angles are 45°, 60°, and 70°; 70° suits near-surface and weld cap inspection, 45° suits thicker sections.

  • Distance amplitude correction (DAC) curves compensate for beam spread and attenuation; record indication height as dB relative to the DAC.

  • Couplant must wet both surfaces and exclude air; glycerin, gel, oil, and water are selected for surface finish and material compatibility.

  • Typical steel velocities: longitudinal about 0.232 in/µs (5900 m/s) and shear about 0.127 in/µs (3230 m/s).

Quick reference

Visual Testing (VT)

  • Minimum illumination at the inspection surface is generally 100 foot-candles (about 1000 lux), with higher levels for small or low-contrast features.

  • Near vision must be corrected to 20/20 (Jaeger J-1 or equivalent) at 12–14 in (300–350 mm) and re-verified at least annually.

  • Direct visual testing requires the eye within 24 in (600 mm) of the surface with a viewing angle of at least 30°, preferably 45°.

  • Remote visual testing uses borescopes, fiberscopes, or cameras; resolution and illumination must be demonstrated at the remote inspection location.

  • Contrast is the luminance difference between indication and background; oblique lighting improves detection of surface-breaking discontinuities.

  • Common aids include magnifiers (2× to 10×), mirrors, weld gauges for undercut, fillet, and hi-lo, and surface comparators.

  • Surfaces must be clean and free of scale, spatter, and coatings that can hide discontinuities or create false indications.

  • Weld examination looks for undercut, porosity, cracks, incomplete fusion, misalignment, and spatter, with size and location recorded.