ASNT NDT Level II flashcards
ASNT NDT Level II · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Skin depth formula
- Depth below the surface where eddy current density falls to about 37% (1/e) of its surface value, given by δ = 1/√(π f μ σ).
- Lift-off effect
- Change in coil-to-part spacing that alters impedance magnitude strongly; it must be held constant, compensated, or phase-rotated out to avoid false indications.
- Fill factor
- Fraction of the coil's internal cross-section occupied by the test part. A higher fill factor concentrates the magnetic field and increases sensitivity, especially on small-diameter tubing.
- Phase angle in eddy current
- Angular position of the impedance-plane signal. It shifts with defect depth and material changes, letting defect signals be separated from lift-off or support plates.
- Remote field testing
- Low-frequency through-wall eddy current technique for ferromagnetic tubing, where the field travels along the wall and is detected by an internal receiver spaced from the exciter.
- Circular magnetization
- Magnetic field running circumferentially around the current path, produced by prods or a central conductor, and used to detect longitudinal defects parallel to the part axis.
- Longitudinal magnetization
- Magnetic field running along the part axis, produced by a coil or head shot, used mainly to detect circumferential defects transverse to the axis.
- Prod current rule
- Prod spacing is normally 3–8 in (75–200 mm), with about 100 amperes per inch of spacing, commonly in the 90–125 A/in range.
- Demagnetization requirement
- Performed after testing when residual magnetism could interfere with machining, welding, or service, using a reversing alternating field reduced gradually to zero.
- Continuous versus residual method
- In the continuous method current flows while particles are applied and sensitivity is higher; the residual method relies on retained magnetism and needs high-retentivity material.
- Capillary action in penetrant
- Force that draws penetrant into tight surface openings; it requires low surface tension and good wetting so the liquid enters narrow discontinuities.
- Post-emulsifiable penetrant
- Penetrant removed by applying an emulsifier before washing. It gives better excess-removal control on rough surfaces and reduces over-washing of indications.
- Developer function
- Forms a thin uniform film that draws penetrant out of discontinuities by capillarity and provides a contrasting background so indications become visible.
- Penetrant dwell time
- Time the penetrant stays on the surface, typically 10–15 minutes, with longer times for tight or shallow discontinuities and for lower temperatures.
- Penetrant temperature limits
- Standard penetrant testing requires surface temperatures between 50 and 125 °F (10–52 °C); outside this range special penetrants or technique qualification are needed.
- Geometric unsharpness formula
- Ug = F·t/d, where F is source size, t is object-to-film distance, and d is source-to-object distance. Smaller focal spots or greater distances sharpen the image.
- Inverse square law
- Radiation intensity varies inversely with the square of distance from the source, so doubling source-to-film distance reduces intensity to one quarter.
- Half-value layer
- Material thickness that reduces radiation intensity by half. It is used to estimate exposure times and shielding for a given radiation energy and material.
- Penetrameter (IQI)
- Image quality indicator of wires or steps placed on the source or film side; the required designation depends on material thickness and specified sensitivity.
- Film density range
- Photographic darkness of a radiograph, typically accepted between 1.8 and 4.0; densities below the code minimum lower contrast and require re-exposure.
- Iridium-192 source
- Gamma source with a 74-day half-life used for steel roughly 0.5 to 3 in thick; Co-60 is chosen for thicker sections.
- Acoustic impedance
- Product of density and sound velocity (Z = ρc). The impedance mismatch at an interface determines how much ultrasonic energy is reflected.
- Near field length
- N = D²f/(4c). Inside this distance the beam is complex and non-uniform, so defect sizing and evaluation are normally done beyond it.
- Snell's law in ultrasonic testing
- sin θ1/c1 = sin θ2/c2. It governs refraction at the wedge-to-part interface and determines the incident angle needed for a desired refracted angle.
- Distance amplitude correction curve
- Plot of echo height versus distance from a reference reflector that compensates for beam spread and attenuation when evaluating and sizing indications.
- First critical angle
- Incident angle at which the refracted longitudinal wave reaches 90 degrees and vanishes; beyond it only refracted shear waves travel in the part.
- Six dB drop method
- Sizing technique in which defect length is bounded by the points where the echo amplitude falls 6 dB from its maximum value.
- Illumination for visual testing
- Generally at least 100 foot-candles (about 1000 lux) at the inspection surface, with higher levels for small or low-contrast indications.
- Visual acuity requirement
- Near vision corrected to at least 20/20, demonstrated with a Jaeger J-1 or equivalent chart at 12–14 in, and re-verified at least annually.
- Direct visual testing
- Examination with the eye no more than 24 in (600 mm) from the surface and a viewing angle of at least 30 degrees, preferably 45 degrees.
- Remote visual testing
- Inspection using borescopes, fiberscopes, or cameras where direct access is impossible; resolution and illumination must be adequate at the remote location.
- Contrast in visual testing
- Luminance difference between an indication and its background; clean surfaces and oblique lighting raise contrast and improve detection reliability.