Question 1NDT General (Basic)

Which quantity is defined as the number of cycles of an alternating current completed in one second?

  1. Frequency Correct answer.
  2. Phase angle
  3. Wavelength
  4. Amplitude

Explanation

Frequency is the count of complete cycles occurring per unit time, expressed in hertz, where one hertz equals one cycle per second. The other listed quantities describe spatial length, magnitude, or timing offset rather than cycle count per second.

Question 2NDT General (Basic)

In the SI system, which unit expresses electrical conductivity?

  1. Ohm-meter
  2. Farad
  3. Tesla
  4. Siemens per meter Correct answer.

Explanation

Conductivity is the reciprocal of resistivity, and the reciprocal of the ohm-meter is the siemens per meter. Ohm-meter expresses resistivity, tesla expresses magnetic flux density, and the farad expresses capacitance.

Question 3NDT General (Basic)

A material is described as ferromagnetic. Which behavior best characterizes it?

  1. It slightly opposes an applied magnetic field
  2. It strongly concentrates and is attracted by magnetic fields Correct answer.
  3. It becomes a perfect conductor at low temperature
  4. It stores electric charge between parallel surfaces

Explanation

Ferromagnetic materials such as iron and nickel have high permeability and are strongly attracted to magnetic fields, concentrating flux within them. Slight opposition describes diamagnetism, and the other choices describe superconductivity and capacitance.

Question 4NDT General (Basic)

Which statement best describes the purpose of a calibration standard in nondestructive testing?

  1. It eliminates all variation between different inspectors
  2. It provides a known reference against which instrument response is verified Correct answer.
  3. It replaces the need for written test procedures
  4. It permanently increases the sensitivity of the test system

Explanation

A calibration standard supplies a known, characterized reference so that instrument readings can be verified and adjusted to a traceable basis. It does not change the inherent capability of the equipment, substitute for procedures, or remove human variability.

Question 5NDT General (Basic)

Which document typically establishes the minimum requirements for qualifying and certifying NDT personnel?

  1. A material purchase order
  2. An equipment calibration certificate
  3. A written practice issued by the employer Correct answer.
  4. A customer drawing

Explanation

The employer's written practice defines how personnel are trained, examined, and certified to the applicable standard. Purchase orders, calibration certificates, and drawings do not govern personnel qualification.

Question 6NDT General (Basic)

A technician reports a measured length as 25.4 mm. Which statement about significant figures is correct?

  1. The value contains five significant figures
  2. The value contains two significant figures
  3. The value contains an unlimited number of significant figures
  4. The value contains three significant figures Correct answer.

Explanation

In 25.4, the digits 2, 5, and 4 are all non-zero and therefore significant, giving three significant figures. Trailing zeros after a decimal point would also count, but there are none here.

Question 7NDT General (Basic)

Which of the following is a basic safety practice when working with industrial electrical test equipment?

  1. Removing ground connections to reduce electrical noise
  2. Bypassing interlocks to speed up testing
  3. De-energizing and locking out circuits before making connections Correct answer.
  4. Working alone so that no one else disturbs the setup

Explanation

Lockout and de-energization isolate hazardous energy before hands-on work, which is a fundamental electrical safety control. Working alone, defeating grounds, or bypassing interlocks all increase risk.

Question 8NDT General (Basic)

Which organization publishes consensus standards widely used across NDT methods in the United States?

  1. The Occupational Safety and Health Administration
  2. The National Fire Protection Association
  3. ASTM International Correct answer.
  4. The Federal Aviation Administration

Explanation

ASTM International develops consensus technical standards, including many that specify NDT methods, practices, and reference blocks. The other bodies regulate aviation, fire protection, or workplace safety rather than issuing general NDT method standards.

Question 9NDT General (Basic)

A coil is wound with 200 turns and carries a current of 0.5 A. What is the magnetomotive force in ampere-turns?

  1. 0.0025
  2. 400
  3. 100 Correct answer.
  4. 200.5

Explanation

Magnetomotive force equals the number of turns multiplied by the current, so 200 turns times 0.5 A equals 100 ampere-turns. Dividing rather than multiplying, or adding the two values, gives the other listed results.

Question 10NDT General (Basic)

An instrument displays a reading of 5.00 units when the true value is 5.10 units. What is the percent error of the reading relative to the true value?

  1. About 2.00 percent
  2. About 1.96 percent Correct answer.
  3. About 0.10 percent
  4. About 10.0 percent

Explanation

Percent error equals the absolute difference divided by the true value, times 100: (0.10/5.10) x 100, which is about 1.96 percent. Dividing by the indicated reading instead of the true value gives about 2.00 percent.

Question 11NDT General (Basic)

Which characteristic of an eddy current test system most directly determines its ability to resolve two closely spaced defects?

  1. The length of the interconnecting cable
  2. The color of the instrument display
  3. The ambient humidity of the inspection area
  4. Spatial resolution governed by coil size and frequency Correct answer.

Explanation

Resolution of adjacent features depends on the effective sensing volume, which is set by coil geometry and the test frequency through skin depth. Display color, cable length, and humidity do not govern resolving power.

Question 12NDT General (Basic)

A test procedure requires a reference standard to be verified before each shift. Which action best satisfies this requirement?

  1. Check the standard against a known artifact and record the result Correct answer.
  2. Inspect the standard visually for scratches
  3. Clean the standard with solvent and return it to storage
  4. Recalibrate the instrument only at annual service

Explanation

Verification means confirming that the reference still produces the expected known response and documenting that check. Cleaning, visual inspection, or annual calibration alone does not demonstrate that the standard remains valid at the start of a shift.

Question 13NDT General (Basic)

Which factor most limits the depth of penetration achievable in an eddy current inspection?

  1. The thickness of the instrument housing
  2. The diameter of the display screen
  3. The number of operators on the job
  4. Skin depth, which decreases as frequency and conductivity increase Correct answer.

Explanation

Eddy current density decays with depth according to skin depth, which shrinks as frequency, conductivity, or permeability increase. Housing thickness, display size, and staffing do not affect electromagnetic penetration.

Question 14NDT General (Basic)

A technician must select a test method for detecting surface-breaking cracks in a nonmagnetic aluminum forging. Which method is most directly suited?

  1. Penetrant testing Correct answer.
  2. Magnetic particle testing
  3. Radiographic testing
  4. Ultrasonic thickness gauging

Explanation

Penetrant testing reveals surface-breaking discontinuities in nonporous materials regardless of magnetic properties, making it suitable for aluminum. Magnetic particle testing requires ferromagnetic material, radiography is insensitive to tight surface cracks, and thickness gauging measures wall thickness.

Question 15NDT General (Basic)

Which statement correctly distinguishes accuracy from precision in measurement?

  1. Accuracy is repeatability; precision is closeness to the true value
  2. Accuracy and precision are synonymous terms in metrology
  3. Accuracy is closeness to the true value; precision is repeatability of readings Correct answer.
  4. Precision applies only to digital instruments

Explanation

Accuracy describes how close a result is to the true value, while precision describes how closely repeated measurements agree with one another. A system can be precise yet biased, or accurate on average yet scattered.

Question 16NDT General (Basic)

An inspector observes that a test result changes when the probe cable is moved. Which cause is most likely?

  1. A change in ambient barometric pressure
  2. A change in the material's conductivity
  3. A drift in the reference standard's dimensions
  4. A intermittent connection or shielding fault in the cable Correct answer.

Explanation

Sensitivity to cable movement points to an intermittent conductor, poor shield termination, or connector fault that alters the signal path. Material conductivity, barometric pressure, and reference dimensions do not change with cable motion.

Question 17NDT General (Basic)

Which practice best supports traceability of NDT measurement results?

  1. Recording only the final accept or reject decision
  2. Using calibration standards whose values are linked to a national metrology institute Correct answer.
  3. Skipping records when results are clearly acceptable
  4. Relying on the manufacturer's nominal instrument specifications

Explanation

Traceability requires an unbroken chain of comparisons linking measurements to recognized national or international standards. Recording only pass/fail outcomes, relying on nominal specifications, or omitting records breaks that chain.

Question 18NDT General (Basic)

A procedure specifies a frequency of 100 kHz. Which value is equivalent?

  1. 100,000 Hz Correct answer.
  2. 10,000 Hz
  3. 1,000 Hz
  4. 1,000,000 Hz

Explanation

The prefix kilo means one thousand, so 100 kHz equals 100 times 1000, or 100,000 Hz. The other values correspond to 1 kHz, 10 kHz, and 1 MHz respectively.

Question 19NDT General (Basic)

A technician calculates a signal-to-noise ratio of 40 dB. What does this indicate about the signal amplitude relative to noise?

  1. The signal amplitude is 40 times the noise amplitude
  2. The signal amplitude is 10,000 times the noise amplitude
  3. The signal amplitude is 100 times the noise amplitude Correct answer.
  4. The signal amplitude is 4 times the noise amplitude

Explanation

For amplitude quantities, decibels equal 20 times the base-10 logarithm of the ratio, so 40 dB corresponds to a ratio of 100. Treating decibels as a direct linear multiplier or as a 10-log ratio yields the incorrect values.

Question 20NDT General (Basic)

Which statement best describes the role of a written NDT procedure in a quality system?

  1. It certifies the individual inspector's competence
  2. It guarantees that no defects will be missed
  3. It replaces the need for instrument calibration
  4. It prescribes the controlled steps and acceptance criteria for a specific test Correct answer.

Explanation

A procedure documents the approved method, parameters, and acceptance criteria so that the test is performed consistently and can be audited. Certification of people, detection guarantees, and calibration are separate elements of the quality system.

Question 21NDT General (Basic)

A cylindrical part is inspected with an encircling coil. Which change would most increase the depth at which eddy currents remain detectable?

  1. Increasing the test frequency
  2. Lowering the test frequency Correct answer.
  3. Increasing the coil current only
  4. Reducing the coil diameter only

Explanation

Skin depth increases as frequency decreases, so lowering frequency allows eddy currents to penetrate more deeply. Raising frequency or current, or shrinking the coil, does not extend penetration depth.

Question 22NDT General (Basic)

Two inspectors measure the same feature repeatedly and obtain tight clusters that are both offset from the true value. Which description applies?

  1. The measurements are both accurate and precise
  2. The measurements are precise but not accurate Correct answer.
  3. The measurements are accurate but not precise
  4. The measurements are neither repeatable nor valid

Explanation

Tight clustering indicates high precision, while the shared offset from the true value indicates a systematic bias that reduces accuracy. Repeatability alone does not ensure correctness.

Question 23NDT General (Basic)

A reference standard used for eddy current setup shows a small but consistent change in response over several months. Which action is most appropriate?

  1. Recalibrate or replace the standard against a higher-level reference Correct answer.
  2. Record the reading and continue without further action
  3. Shorten the inspection time per part
  4. Increase the instrument gain to compensate

Explanation

A drifting reference no longer provides a valid known basis, so it must be recalibrated or replaced using a higher-level standard to restore traceability. Gain adjustment masks the problem, and ignoring the drift compromises all subsequent results.

Question 24NDT General (Basic)

An eddy current inspection of a ferromagnetic tube is planned. Which consideration most affects the interpretation of results compared with a nonmagnetic tube?

  1. High permeability concentrates flux and alters the expected impedance response Correct answer.
  2. The test frequency must always be set to zero
  3. The material cannot support eddy currents at all
  4. Skin depth becomes independent of frequency

Explanation

In ferromagnetic material, high permeability strongly influences field distribution and the impedance plane response, so interpretation and setup differ from nonmagnetic cases. Eddy currents still flow, frequency remains meaningful, and skin depth still depends on frequency.

Question 25NDT General (Basic)

A quality audit finds that an inspector used an expired calibration certificate for a reference instrument. Which conclusion is most defensible?

  1. Results are valid because the instrument still powered on
  2. Results are valid because the certificate exists in the file
  3. Results obtained with that instrument lack demonstrated traceability Correct answer.
  4. Results are valid if the inspector was certified

Explanation

Traceability depends on calibration being current; an expired certificate breaks the demonstrated chain of comparison. Functional operation, personnel certification, or the mere presence of a document does not restore valid calibration status.

Question 26NDT General (Basic)

Which physical quantity is defined as the opposition a material offers to the flow of electric current?

  1. Resistance Correct answer.
  2. Impedance
  3. Reluctance
  4. Conductance

Explanation

Resistance is the property that opposes current flow in a conductor and is measured in ohms. Conductance is its reciprocal, reluctance applies to magnetic circuits, and impedance is the combined opposition in AC circuits.

Question 27NDT General (Basic)

In an eddy current test, what is the primary effect of raising the test frequency while holding all other variables constant?

  1. Standard depth of penetration increases
  2. Conductivity of the part increases
  3. Standard depth of penetration decreases Correct answer.
  4. Magnetic permeability of the part decreases

Explanation

Standard depth of penetration varies inversely with the square root of frequency, so increasing frequency concentrates eddy currents nearer the surface. Material properties such as conductivity and permeability are not changed by the test frequency itself.

Question 28NDT General (Basic)

Which term describes a material that loses essentially all magnetization when the applied magnetizing force is removed?

  1. Paramagnetic
  2. Diamagnetic
  3. Magnetically soft Correct answer.
  4. Magnetically hard

Explanation

Soft magnetic materials have low coercivity and retain little magnetization once the field is removed, which is why they are used in cores and coils. Hard magnetic materials retain magnetization strongly and behave as permanent magnets.

Question 29NDT General (Basic)

What does the abbreviation NDT stand for?

  1. Nominal defect testing
  2. Neutral density testing
  3. Nondeforming testing
  4. Nondestructive testing Correct answer.

Explanation

NDT refers to inspection methods that examine a component for defects or property variations without impairing its serviceability. The other expansions are not standard terminology in the field.

Question 30NDT General (Basic)

Which statement best describes the purpose of a calibration program for NDT instruments?

  1. To establish the relationship between instrument indications and known reference values Correct answer.
  2. To extend the service life of the instrument
  3. To satisfy customer paperwork requirements
  4. To increase the maximum output of the instrument

Explanation

Calibration establishes and documents how an instrument's output corresponds to known standards so that indications can be interpreted reliably. It does not change the instrument's design performance or lifespan.

Question 31NDT General (Basic)

A technician must report a measured value in SI units. Which unit expresses electrical conductivity?

  1. Tesla
  2. Weber
  3. Siemens per meter Correct answer.
  4. Ohm-meter

Explanation

Conductivity is the reciprocal of resistivity and is expressed in siemens per meter in SI units. Ohm-meter is a resistivity unit, while tesla and weber are magnetic units.

Question 32NDT General (Basic)

Which of the following is a recognized advantage of nondestructive testing over destructive testing?

  1. The test eliminates the need for written procedures
  2. The tested part can remain available for service Correct answer.
  3. The test requires no trained personnel
  4. The test always detects every defect present

Explanation

Because NDT does not damage the component, inspected parts can often continue in service. NDT still requires qualified personnel, documented procedures, and has detection limits.

Question 33NDT General (Basic)

What does the term 'lift-off' refer to in an eddy current inspection?

  1. The change in frequency during scanning
  2. The force needed to remove a magnet from the part
  3. The spacing between adjacent probe coils
  4. The gap between the coil and the test surface Correct answer.

Explanation

Lift-off is the spacing or gap between the coil and the surface of the part, which changes coil impedance and can mask or mimic defect signals. It is controlled through probe design and scanning technique.

Question 34NDT General (Basic)

A coil has an inductive reactance of 300 ohms and a resistance of 400 ohms. What is the magnitude of its impedance?

  1. 100 ohms
  2. 350 ohms
  3. 700 ohms
  4. 500 ohms Correct answer.

Explanation

Impedance magnitude for a series combination is the square root of the sum of the squares of resistance and reactance. Here the square root of 400 squared plus 300 squared equals 500 ohms.

Question 35NDT General (Basic)

Which eddy current test parameter is most useful for suppressing the effect of small variations in probe-to-surface spacing?

  1. Fill factor
  2. Phase analysis Correct answer.
  3. Coil diameter
  4. Frequency selection

Explanation

Lift-off and defect signals typically differ in phase, so phase analysis can separate them even when amplitudes overlap. Frequency, coil diameter, and fill factor affect sensitivity but do not by themselves discriminate lift-off from defects.

Question 36NDT General (Basic)

Why is a ferromagnetic material often tested with eddy currents only after magnetization effects are addressed?

  1. The material becomes nonconductive when magnetized
  2. Permeability variations can dominate the signal and mask defects Correct answer.
  3. The coil inductance drops to zero
  4. Eddy currents cannot exist in ferromagnetic materials

Explanation

In ferromagnetic materials, permeability variations produce large impedance changes that can overwhelm defect signals. Techniques such as saturation or appropriate frequency selection are used to reduce this influence.

Question 37NDT General (Basic)

A technician needs to detect very small surface defects on a thin conductive sheet. Which combination is most appropriate?

  1. High frequency with a large encircling coil
  2. High frequency with a small coil Correct answer.
  3. Low frequency with a large coil
  4. Low frequency with a large fill factor

Explanation

High frequency concentrates eddy currents near the surface where small surface defects lie, and a small coil improves spatial resolution. Low frequency and large coils reduce surface sensitivity and resolution.

Question 38NDT General (Basic)

Which statement best describes the function of a phase shifter in an eddy current instrument?

  1. It rotates the displayed signal to place a feature of interest at a chosen reference angle Correct answer.
  2. It increases the frequency applied to the coil
  3. It amplifies the coil drive current
  4. It filters out all high-frequency noise

Explanation

A phase shifter rotates the signal display so that a selected signal, such as a defect or lift-off, can be aligned to a convenient reference angle for interpretation. It does not change frequency or drive current.

Question 39NDT General (Basic)

A technician records an eddy current signal amplitude that varies by 15 percent between repeated scans of the same known defect. Which action is most appropriate before accepting the results?

  1. Report the highest amplitude as the true value
  2. Reduce the gain until the variation disappears
  3. Ignore the variation because eddy current testing is qualitative
  4. Investigate scan speed, coupling, and setup repeatability Correct answer.

Explanation

Repeatability problems usually trace to controllable variables such as scan speed, lift-off, or setup stability. These should be identified and corrected before results are accepted. Adjusting gain or selecting a value does not address the cause.

Question 40NDT General (Basic)

Which factor determines the fill factor in an internal through-coil inspection of a tube?

  1. The ratio of tube length to coil length
  2. The ratio of tube conductivity to coil conductivity
  3. The ratio of test frequency to the tube's cutoff frequency
  4. The ratio of the coil's cross-sectional area to the tube's internal cross-sectional area Correct answer.

Explanation

Fill factor describes how completely the coil fills the available space in the tube, expressed as an area ratio. A high fill factor improves coupling and signal strength.

Question 41NDT General (Basic)

An inspector must verify that an eddy current instrument's frequency display is accurate. Which approach is most direct?

  1. Verify the display against the procedure's stated frequency
  2. Check the instrument against another instrument of the same model
  3. Measure the oscillator output with a calibrated frequency counter Correct answer.
  4. Compare the display to the coil's nameplate rating

Explanation

The most direct verification compares the actual oscillator output to a calibrated reference such as a frequency counter. Comparing displays or nameplates does not establish traceable accuracy.

Question 42NDT General (Basic)

Which statement best describes the skin effect in eddy current testing?

  1. Current density is uniform throughout the conductor
  2. Current density increases with depth into the conductor
  3. Current flows only on the far surface of the conductor
  4. Current density decreases with depth into the conductor Correct answer.

Explanation

The skin effect causes alternating current density to be highest at the surface and to decrease exponentially with depth. This behavior underlies the concept of standard depth of penetration.

Question 43NDT General (Basic)

A procedure requires a reference standard with known artificial defects. Which characteristic is most important for that standard?

  1. The defects are reproducibly located and sized Correct answer.
  2. The standard is larger than the parts being inspected
  3. The standard is made from the same alloy batch as production parts
  4. The standard is stored in the inspection area

Explanation

Reference standards must provide consistent, known responses so that system settings and sensitivity can be verified repeatably. Reproducible defect location and size are the essential characteristics.

Question 44NDT General (Basic)

Which of the following best explains why eddy current testing is generally limited to relatively thin or surface-near regions?

  1. Eddy current density attenuates rapidly with depth Correct answer.
  2. Eddy currents cannot be induced in thick materials
  3. Coils cannot generate fields in thick materials
  4. Thick materials are always nonconductive

Explanation

Because eddy current density falls off with depth according to the skin effect, useful signal is confined to a shallow region near the surface. This is a physical attenuation effect, not a prohibition on testing thick parts.

Question 45NDT General (Basic)

An inspector notices that the eddy current signal amplitude drifts steadily during a long inspection. Which cause is most likely?

  1. A change in the part's alloy specification
  2. A defect passing under the coil
  3. Thermal drift in the instrument electronics Correct answer.
  4. A sudden change in part conductivity

Explanation

Gradual drift over time is characteristic of thermal effects in electronics and is typically addressed by warm-up and periodic restandardization. Defects and material changes produce discrete signal changes rather than steady drift.

Question 46NDT General (Basic)

Which of the following best describes the role of a qualified Level III in an NDT organization?

  1. Performing only routine production scans
  2. Developing and interpreting procedures and establishing technique requirements Correct answer.
  3. Scheduling inspection personnel
  4. Maintaining the instrument inventory

Explanation

Level III personnel are responsible for procedure development, technique selection, and interpretation of standards and results. Routine scanning and administrative tasks are not the defining Level III function.

Question 47NDT General (Basic)

A technician must choose between two coils for inspecting a tube: one with a fill factor of 0.9 and one with 0.5. Which statement is correct?

  1. The 0.9 fill factor coil provides stronger coupling and better sensitivity Correct answer.
  2. The 0.5 fill factor coil provides stronger coupling and better sensitivity
  3. The 0.5 fill factor coil is preferred because lower coupling reduces noise
  4. Fill factor has no effect on signal strength

Explanation

A higher fill factor means the coil more completely occupies the available space, improving electromagnetic coupling and signal strength. Lower fill factor reduces coupling and sensitivity.

Question 48NDT General (Basic)

An eddy current signal from a known defect appears at a phase angle of 40 degrees, while a lift-off signal appears at 130 degrees. Which approach best isolates the defect response?

  1. Set the phase so that the lift-off signal is suppressed while the defect signal is retained Correct answer.
  2. Increase the gain until both signals are equal in amplitude
  3. Reduce the frequency until both signals merge
  4. Increase the scan speed to separate the signals in time

Explanation

When signals differ in phase, phase discrimination can suppress one while retaining the other. Amplitude or speed changes do not separate signals that overlap in time and differ only in phase.

Question 49NDT General (Basic)

A technician observes that the eddy current response to a known defect decreases as the coil is tilted relative to the surface. Which explanation is most consistent with this observation?

  1. Tilting changes the effective lift-off and coupling, reducing signal amplitude Correct answer.
  2. Tilting changes the conductivity of the material
  3. Tilting reverses the direction of eddy current flow
  4. Tilting increases the test frequency

Explanation

Tilting the coil increases the average gap and alters coupling between coil and part, which reduces signal amplitude. It does not change material conductivity or the applied frequency.

Question 50NDT General (Basic)

In a quality system, which document typically defines the minimum qualifications and certification requirements for NDT personnel?

  1. The purchase order for inspection services
  2. A written practice approved by the employer Correct answer.
  3. The instrument operating manual
  4. The material test report

Explanation

A written practice describes how the employer implements qualification and certification requirements for its NDT personnel. Instrument manuals and commercial documents do not define personnel qualifications.