ASNT Level III IR flashcards
ASNT Level III IR · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Wien's displacement law
- The peak wavelength of blackbody emission is inversely proportional to absolute temperature, lambda_max = 2898/T micrometres. At 300 K the peak is near 9.7 micrometres.
- Stefan-Boltzmann law
- Total radiant exitance of a blackbody equals sigma times T to the fourth power. For real surfaces multiply by emissivity, making exitance strongly sensitive to temperature.
- Kirchhoff's law
- For an opaque body in thermal equilibrium, spectral emissivity equals spectral absorptivity at each wavelength and temperature. Good absorbers are good emitters.
- Emissivity definition
- Ratio of radiation emitted by a real surface to that of a blackbody at the same temperature and wavelength. Values range from 0 to 1.
- Graybody assumption
- A body whose emissivity is constant across wavelength but less than one. Simplifies radiometric temperature calculation but is an approximation for most real materials.
- Atmospheric IR windows
- Wavelength bands where atmospheric transmission is high, principally 2-5.6 micrometres and 8-14 micrometres. Outside these bands water vapor and CO2 absorb strongly.
- Reflected apparent temperature
- The temperature of radiation reflected from the target into the camera, used by the camera to correct indicated temperature. Set it from a diffuse reflector near the target.
- Blackbody reference source
- A calibrated cavity radiator with known high emissivity used to verify or calibrate infrared cameras and confirm radiometric accuracy in the field or lab.
- NETD
- Noise-equivalent temperature difference: the target temperature change producing a signal equal to RMS noise. Lower values indicate better thermal sensitivity.
- Detectivity D*
- Normalized measure of detector sensitivity that accounts for detector area and bandwidth. Higher D* indicates a more sensitive detector.
- Microbolometer
- Uncooled thermal detector array whose resistance changes with absorbed infrared energy. Common in LWIR handheld and fixed cameras.
- Photon detector cooling
- Photon detectors such as InSb and MCT require cryogenic or thermoelectric cooling to reduce thermal noise and achieve high sensitivity and fast response.
- IFOV
- Instantaneous field of view: the angular subtense of one detector element, equal to detector size divided by focal length. Determines smallest resolvable target at a distance.
- Measurement field of view
- The area over which the camera averages temperature, commonly taken as three by three pixels. The target should fill at least this area.
- Radiometric accuracy
- Camera specification stating maximum temperature error under defined conditions, often plus or minus two degrees Celsius or two percent of reading.
- Active thermography
- Inspection technique that applies external energy to the target and observes the resulting thermal response, enabling detection of subsurface features and defects.
- Passive thermography
- Inspection that observes natural temperature differences without added excitation, commonly used for electrical, mechanical, and building envelope surveys.
- Pulsed phase thermography
- Technique that transforms pulsed thermal data into phase images via Fourier analysis, reducing sensitivity to emissivity variation and non-uniform heating.
- Lock-in thermography
- Periodic excitation at a fixed frequency with synchronous detection to extract amplitude and phase images, improving signal-to-noise for subtle defects.
- Building envelope delta-T
- Minimum steady indoor-outdoor temperature difference, often about ten degrees Celsius, needed for meaningful infrared surveys of insulation and air leakage.
- Electrical load requirement
- Thermographic inspection of electrical equipment should be performed under load near normal operating levels so abnormal heating is detectable.
- Comparative analysis
- Evaluating a component's temperature relative to similar components under similar load and conditions, rather than relying only on absolute temperature.
- False indication causes
- Reflections, emissivity variation, solar loading, and wind can create thermal patterns unrelated to defects. Verify by changing angle or repeating the inspection.
- Thermal bridge
- A localized path of high heat flow through an assembly, producing a distinct thermal pattern that must be distinguished from defects during interpretation.
- Severity classification
- Assigning a significance level to an anomaly based on pattern, temperature rise, and comparison to criteria, with the basis documented in the report.
- Detection limit
- The smallest defect or temperature difference reliably detectable under stated conditions; should be acknowledged in the inspection report.
- ASTM E1934
- Standard guide for examining electrical and mechanical equipment using infrared thermography, covering procedures, equipment, and reporting.
- ASTM E1933
- Standard practice for measuring and compensating for emissivity when using infrared imaging radiometers, including reference and contact methods.
- ASTM E1186
- Standard practice for air leakage detection in building envelopes using infrared thermography, addressing conditions and interpretation.
- ISO 18434-1
- Standard covering condition monitoring and diagnostics of machines using thermography, providing general procedures and guidance for industrial applications.
- SNT-TC-1A
- ASNT recommended practice for employer-written personnel qualification and certification programs in nondestructive testing, including training and examination guidance.
- Level III responsibilities
- Establishing and interpreting procedures and standards, administering the qualification program, and providing technical direction for the method within the employer's organization.