The ASNT NDT Level III certification is a professional credential in nondestructive testing, with Infrared Testing (IR) as one of the method-specific endorsements a Level III candidate can pursue. Level III personnel are typically the people who write and approve NDT procedures, interpret codes and specifications, select techniques and equipment, evaluate and sign off on results, and supervise or qualify Level I and Level II staff - so the IR exam is aimed at experienced infrared thermographers moving into that technical-leadership and program-ownership role rather than at entry-level operators. The ASNT Level III IR study guide has 6 sections and about 1,754 words.

01

Infrared Testing (IR) Method Fundamentals and Physics

Infrared testing relies on detecting thermal radiation emitted by objects according to their temperature. The fundamental relationship is given by Planck's law, which describes the spectral radiance of a blackbody as a function of wavelength and temperature.

385 words, about 2 min
02

Infrared Equipment, Detectors, and System Performance

Infrared systems use detectors that convert IR radiation into electrical signals. Two main classes: thermal detectors (e.g., microbolometers, thermopiles) respond to temperature changes and are generally uncooled, while photon detectors (e.g., InSb, HgCdTe, InGaAs) require cooling (often to cryogenic temperatures) for high sensitivity and fast response.

392 words, about 2 min
03

Test Procedures, Techniques, and Applications

Infrared testing procedures must be tailored to the application, whether predictive maintenance, building diagnostics, or electrical inspections. Key steps include: defining the objective, selecting appropriate equipment (spectral range, sensitivity, lens), preparing the scene (cleaning, minimizing reflections, ensuring proper emissivity), and establishing environmental conditions (temperature, humidity, wind, solar loading).

286 words, about 1 min
04

Interpretation and Evaluation of Results

Interpretation involves distinguishing true thermal anomalies from artifacts. Common artifacts include reflections (from low-emissivity surfaces), solar loading, wind cooling, and emissivity variations.

259 words, about 1 min
05

Codes, Standards, and Specifications

Infrared testing is governed by various standards. ASTM E1934 covers examination of electrical and mechanical equipment; ASTM E1186 for building diagnostics; ISO 18434-1 for machinery condition monitoring; NFPA 70B for electrical maintenance.

213 words, about 1 min
06

Personnel Qualification, Certification, and Administration

Personnel qualification in infrared testing is often based on ASNT Recommended Practice No. SNT-TC-1A or ANSI/ASNT CP-189.

219 words, about 1 min