ASNT NDT III LT study materials
ASNT NDT III LT study resources

ASNT NDT III LT cheat sheet

ASNT NDT III LT · Keep the key ideas within reach.

Quick reference

Leak Testing (LT) Method Fundamentals and Techniques

  • Leak rate Q for viscous flow through a capillary: Q = π d^4 ΔP / (128 μ L), where d is diameter, L length, μ viscosity, ΔP pressure drop.

  • Molecular flow conductance for a long tube: C = (π d^3 / (12 L)) √(2π R T / M), where R is gas constant, T temperature, M molar mass.

  • Bubble immersion test: leak rate (std cm³/s) ≈ (bubble volume)/(time to form bubble) × (bubble count), corrected to standard conditions.

  • Pressure decay test: leak rate Q = (V ΔP) / (Δt Patm), assuming ideal gas and isothermal conditions; V is test volume.

  • Helium mass spectrometer leak detector: minimum detectable leak typically 1×10^-10 std cm³/s; calibrated with a certified leak standard.

  • Vacuum test (hood test): tracer gas applied to outside of evacuated component; leak rate = (signal rise × calibrated sensitivity) / response time.

  • Ultrasonic leak detection: detects turbulent flow noise; effective for pressure differentials > 5 psi and leak rates > 1×10^-3 std cm³/s.

  • Halogen diode detector: sensitive to halogen gases; minimum detectable leak ~1×10^-6 std cm³/s; sensor can be poisoned by exposure to high concentrations.

Quick reference

Leak Testing Method Qualification, Administration, and Procedure Development

  • Qualification of LT procedures requires demonstration of repeatability and reproducibility; typically three runs by two operators on a known leak standard.

  • Calibration of leak detection equipment must be traceable to a national standard (e.g., NIST) and performed at intervals specified in the written procedure.

  • A leak standard must be certified and have a known leak rate; its uncertainty should be ≤ 1/3 of the tolerance being measured.

  • Procedure qualification record (PQR) must include test method, tracer gas, pressure, temperature, equipment, and acceptance criteria.

  • Environmental factors (temperature, background tracer gas, humidity) must be controlled or compensated during leak testing.

  • Acceptance criteria for leak tests are typically expressed as maximum allowable leak rate in std cm³/s or mbar·L/s.

  • Personnel performing leak tests must be qualified to the applicable standard (e.g., SNT-TC-1A) with vision acuity and training records.

Quick reference

General NDT Knowledge and Basic Physics

  • Ideal gas law: PV = nRT; used to convert leak rates to standard conditions (T=273 K, P=1 atm).

  • Viscosity of gases increases with temperature; for gases μ ∝ T^0.5 approximately.

  • Speed of sound in gas: c = √(γ R T / M), where γ is specific heat ratio.

  • Vacuum units: 1 atm = 760 torr = 101325 Pa = 1.01325 bar; 1 std cm³/s = 0.001 Pa·m³/s.

  • Leak rate conversion: 1 std cm³/s = 0.001 mbar·L/s = 0.1 Pa·L/s.

  • Pressure measurement: Bourdon tube for gauge pressure, Pirani gauge for rough vacuum, ionization gauge for high vacuum.

  • Flow regimes: viscous flow (continuum) when Knudsen number Kn < 0.01; molecular flow when Kn > 1; transitional in between.

  • NDT methods include VT, PT, MT, UT, RT, ET, LT; selection depends on material, defect type, and accessibility.

Quick reference

Certification Program Administration and Standards (SNT-TC-1A, CP-189)

  • SNT-TC-1A: employer-written practice; certification levels I, II, III; training hours and experience requirements are minimums.

  • CP-189: establishes minimum requirements for qualification and certification of NDT personnel; more prescriptive than SNT-TC-1A.

  • Level III responsibilities include procedure approval, interpretation of codes, and training/certification of Level I and II personnel.

  • Certification requires documented training, experience, and passing a general, specific, and practical examination.

  • Recertification: every 5 years for SNT-TC-1A; annual vision test (Jaeger 1 or equivalent) required.

  • Level III examination includes a basic exam, method exam, and a practical exam; passing score typically 80%.

  • Employer must maintain certification records including examination results, experience, and vision tests.