ASSE 5120 flashcards
ASSE 5120 · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Cross-connection
- Any actual or potential physical link between a potable water system and a source of contamination or pollution that could allow unwanted material to enter the drinking water supply.
- Backflow
- The unintended reverse flow of water or another substance into a potable water distribution system, caused by either backsiphonage or backpressure conditions within the piping.
- Backsiphonage
- Backflow produced by a negative or sub-atmospheric pressure in the supply piping, which draws downstream liquid into the potable system through an unprotected cross-connection.
- Backpressure
- Backflow caused when pressure downstream of a connection exceeds the supply pressure, forcing water backward; common sources are boilers, pumps, and elevated storage.
- Pollutant versus contaminant
- A pollutant impairs taste, odor, or appearance without creating a health hazard; a contaminant causes an actual health hazard, so it demands higher-level protection.
- Air gap protection
- A physical separation between the supply outlet and the flood-level rim of the receiving vessel, giving absolute protection without mechanical parts that can fail.
- Pounds per square inch to head
- One psi equals 2.31 feet of water column, and one foot of water column equals 0.433 psi; these conversions let you translate gauge readings into elevation head.
- Atmospheric pressure at sea level
- Standard atmospheric pressure is about 14.7 psi, or 101.3 kilopascals, which limits the maximum theoretical vacuum a backsiphonage condition can create.
- Orifice flow relationship
- Flow through a fixed opening varies with the square root of the pressure differential, so quadrupling the differential doubles the discharge rate through that orifice.
- Friction loss and velocity
- Friction head loss in a given pipe rises approximately with the square of velocity, so doubling the flow rate produces roughly four times the loss per unit length.
- Water hammer
- A pressure surge created by rapid changes in flow velocity, such as fast valve closure, which can damage piping and backflow assembly internals.
- Thermal expansion backflow
- Heating water in a closed system isolated by a check valve raises pressure, which can force water backward or require a thermal expansion control device.
- Cavitation damage
- Vapor bubbles forming where local pressure drops below vapor pressure collapse violently, eroding check components and causing chatter or premature assembly failure.
- Atmospheric vacuum breaker
- A device with an air inlet that opens at atmospheric pressure, installed at least six inches above downstream outlets and unsuitable for continuous pressure or backpressure.
- Pressure vacuum breaker
- A spring-loaded check combined with an air inlet, installed at least twelve inches above the highest downstream outlet, protecting only against backsiphonage.
- Double check valve assembly
- Two independently acting check valves with test cocks, used for low-hazard protection against both backsiphonage and backpressure, with no relief vent to atmosphere.
- Reduced pressure principle assembly
- A high-hazard assembly with two spring-loaded checks and a differential relief valve that discharges when supply pressure drops or the first check fails.
- Spill-resistant vacuum breaker
- A pressure vacuum breaker variant with a loaded air inlet check that seals during normal operation to prevent spilling, still limited to backsiphonage protection.
- Detector assembly purpose
- Fire-line assemblies with a metered bypass and small check valve that detect unauthorized water use while still protecting the potable main from backflow.
- Hose-bibb vacuum breaker
- A small threaded device for hose connections that admits air on backsiphonage; it cannot be used under continuous pressure or where backpressure exists.
- Differential pressure test kit
- The field instrument with a needle valve, sight tube, and calibrated gauge used to measure check holding pressures and relief valve opening points.
- RP relief valve criterion
- The relief valve should open when the differential between the two check zones falls to about two psi or less, confirming hydraulic dependence.
- Check valve holding test
- A test confirming each check resists reverse flow and records the differential pressure at which it holds, commonly at least one psi.
- PVB air inlet test
- A test verifying the air inlet opens at one psi or more of negative pressure and that the check holds at least one psi against reverse flow.
- Pre-test isolation steps
- Confirm no downstream flow, close isolation valves, and flush test cocks before measuring, then restore the assembly and check for leaks afterward.
- Gauge calibration record
- Documented certification of test gauge accuracy against a known reference, since gauge error becomes test-result error and can invalidate reported readings.
- ASSE device standards
- Numbered standards identify devices, such as 1001 for atmospheric vacuum breakers, 1013 for double check assemblies, and 1015 for reduced pressure assemblies.
- Containment versus isolation
- Containment protects the public main at the service connection; isolation protects fixtures and processes inside the building at each point of use.
- Testing frequency
- Annual testing is typical, but local ordinance governs; installation, repair, relocation, and change of use often trigger additional required tests.
- Program administrative elements
- An effective cross-connection program includes an ordinance, hazard surveys, device inventory, certified testers, records retention, and enforcement procedures.
- Required test report records
- Reports should capture device make, model, serial number, size, location, gauge readings, tester identity and certification, date, and pass or fail result.
- Failed device handling
- A failed assembly is tagged, reported to the purveyor, and either repaired and retested or replaced; the purveyor may order service interruption.