Plumbing and Mechanical Code Fundamentals

  • The plumbing code regulates the water supply, sanitary drainage, venting, storm drainage, and fixture systems within a building; the mechanical code governs HVAC, refrigeration, and related equipment.

  • A fixture unit (FU) is a dimensionless measure of the probable load a fixture places on the drainage or water supply system; 1 FU equals 1 cubic foot per minute (cfm) of drainage flow or 1 gallon per minute (gpm) of water supply.

  • The building drain extends from the building to the building sewer; the building sewer begins at the building foundation and runs to the public sewer or private disposal system.

  • The drainage system must be designed to convey the peak discharge without surcharge; the water supply system must deliver the peak demand at the minimum residual pressure required by the code.

  • The minimum size of a building water service is 3/4 inch; the minimum size of a building drain is 4 inches for buildings with more than one water closet.

  • Stack vents and vent stacks must extend at least 6 inches above the roof and at least 12 inches above any roof surface used for other purposes; the vent terminal must be at least 10 feet from any lot line, opening, or air intake.

  • The code establishes a minimum trap arm length and a maximum developed length based on pipe diameter; the trap arm must be at least two pipe diameters in length and the fixture must be vented within the prescribed distance.

  • A plumbing permit is required for the installation, alteration, repair, or replacement of a plumbing system; minor repairs and replacement of fixtures may be exempted by the authority having jurisdiction.

Quick reference

Water Supply and Distribution Systems

  • The water service pipe must be sized to deliver the peak demand at a residual pressure of at least 8 psi at the highest fixture; the minimum static pressure at the service entry is typically 20 psi.

  • The minimum size of a water service is 3/4 inch; the minimum size of a water distribution pipe is 1/2 inch, except that a 3/8-inch pipe may serve a single fixture with a low demand.

  • The water distribution system must be designed to limit the velocity of flow to 8 feet per second in metallic pipe and 5 feet per second in plastic pipe to reduce noise and erosion.

  • Pressure-reducing valves are required when the static pressure exceeds 80 psi; a pressure-relief valve or thermal expansion tank is required on a closed system to prevent excessive pressure from thermal expansion.

  • The minimum size of a water heater drain pan is 1.5 inches deep and must be at least 3 inches larger in diameter than the water heater; the pan must be piped to a drain with a minimum 3/4-inch pipe.

  • The water supply system must be protected against backflow by an air gap, a reduced pressure principle backflow preventer, a double check valve assembly, or a vacuum breaker, depending on the degree of hazard.

  • The minimum diameter of a water service for a single-family dwelling is 3/4 inch; the minimum diameter of a water meter is 5/8 inch.

  • The water distribution system must be tested at a pressure of at least 100 psi for at least 60 minutes; the pressure must not drop more than 5 psi during the test.

Quick reference

Sanitary Drainage, Venting, and Storm Drainage

  • The slope of a horizontal drainage pipe must be at least 1/4 inch per foot for pipe sizes 2 inches and smaller, and at least 1/8 inch per foot for pipe sizes 3 inches and larger.

  • The minimum size of a building drain is 4 inches; the minimum size of a building sewer is 4 inches; the minimum size of a soil stack is 3 inches.

  • A horizontal drainage pipe must be supported at intervals not exceeding 4 feet for cast iron, 4 feet for plastic, and 10 feet for copper; vertical pipe must be supported at each story.

  • A vent stack must extend at least 6 inches above the roof and at least 12 inches above any roof surface used for other purposes; the vent terminal must be at least 10 feet from any lot line, opening, or air intake.

  • The maximum developed length of a trap arm is based on the pipe diameter: 1-1/2 inch = 6 feet, 2 inch = 8 feet, 3 inch = 12 feet, and 4 inch = 16 feet, unless the fixture is vented by a circuit vent or other approved method.

  • A cleanout must be installed at the base of each soil stack, at the building drain, and at intervals not exceeding 100 feet in horizontal drainage pipes; cleanouts must be accessible.

  • Storm drainage must be sized to handle the rainfall intensity for the area; the minimum size of a storm drain is 3 inches; the slope must be at least 1/8 inch per foot for pipe sizes 3 inches and larger.

  • A backwater valve is required on the building sewer when the building drain is below the elevation of the public sewer; the valve must be accessible for maintenance.

Quick reference

Fixtures, Fixture Fittings, and Water Heaters

  • The minimum water closet flush volume is 1.6 gallons per flush; the minimum urinal flush volume is 1.0 gallon per flush; the minimum showerhead flow rate is 2.5 gallons per minute at 80 psi.

  • The minimum lavatory faucet flow rate is 2.2 gallons per minute at 60 psi; the minimum kitchen sink faucet flow rate is 2.2 gallons per minute at 60 psi.

  • The water heater must be installed with a temperature and pressure relief valve; the relief valve must be piped to a safe location and must not be connected to the drainage system without an air gap.

  • The water heater must be secured to resist seismic forces; the strapping must be installed at the upper and lower thirds of the tank and must be capable of resisting a horizontal force of 0.5 times the weight of the water heater.

  • The minimum size of a water heater drain pan is 1.5 inches deep and must be at least 3 inches larger in diameter than the water heater; the pan must be piped to a drain with a minimum 3/4-inch pipe.

  • A fixture must be provided with a trap; the trap must be of the same size as the fixture drain; the trap seal must be at least 2 inches and not more than 4 inches deep.

  • The minimum clearance between a fixture and a wall or partition is 15 inches from the centerline of the fixture to the wall; the minimum clearance between two fixtures is 30 inches center-to-center.

  • The water heater must be provided with a shutoff valve on the cold water supply; a check valve or backflow preventer is required on the cold water supply to prevent thermal expansion from backflowing into the public water system.

Quick reference

Cross-Connection Control and Backflow Prevention

  • A cross-connection is any actual or potential connection between a potable water system and any nonpotable source; backflow is the reversal of flow in a water system.

  • Backsiphonage is backflow caused by negative pressure in the supply system; backpressure is backflow caused by pressure in the nonpotable system exceeding the supply pressure.

  • An air gap is the most effective backflow prevention device; it must be at least twice the diameter of the supply pipe and never less than 1 inch.

  • A reduced pressure principle backflow preventer (RPZ) is required for high-hazard applications; it consists of two independently acting check valves and a differential pressure relief valve.

  • A double check valve assembly (DCVA) is used for low-hazard applications; it consists of two independently acting check valves and must be tested annually.

  • A pressure vacuum breaker (PVB) must be installed at least 12 inches above the highest downstream outlet; it is used for low-hazard applications.

  • An atmospheric vacuum breaker (AVB) must be installed at least 6 inches above the highest downstream outlet; it cannot be used under continuous pressure.

  • Backflow prevention devices must be tested at the time of installation and at least annually thereafter; the test results must be filed with the authority having jurisdiction.

Quick reference

Inspection, Testing, and Plan Review

  • The water distribution system must be tested at a pressure of at least 100 psi for at least 60 minutes; the pressure must not drop more than 5 psi during the test.

  • The drainage system must be tested by a water test, an air test, or a smoke test; the water test must be conducted by filling the system with water to a depth of at least 10 feet above the highest point of the system.

  • The air test for the drainage system must be conducted at a pressure of at least 5 psi for at least 15 minutes; the pressure must not drop more than 1 psi during the test.

  • The building sewer must be tested by a water test or an air test; the water test must be conducted by filling the sewer with water to a depth of at least 10 feet above the highest point of the sewer.

  • The final inspection must be conducted after all plumbing work is complete and before the system is placed in operation; the inspection must verify that all fixtures, appurtenances, and devices are installed in accordance with the approved plans.

  • Plan review must verify that the plumbing system complies with the code; the review must include the sizing of the water supply and drainage systems, the venting system, and the backflow prevention devices.

  • The authority having jurisdiction may require additional inspections for special plumbing systems, such as medical gas systems, grease interceptors, and private sewage disposal systems.

  • The permit holder must notify the authority having jurisdiction when the work is ready for inspection; the notice must be given at least 24 hours before the inspection.

Quick reference

Administration, Permits, and Code Enforcement

  • A plumbing permit is required for the installation, alteration, repair, or replacement of a plumbing system; minor repairs and replacement of fixtures may be exempted by the authority having jurisdiction.

  • The permit application must include a description of the work, the location, the name and address of the owner, and the name and license number of the plumber.

  • The permit must be posted on the job site; the permit is valid for a period of 180 days from the date of issuance; the permit may be extended for an additional 180 days upon written request.

  • The authority having jurisdiction may revoke a permit if the work is not performed in accordance with the approved plans or the code; the permit holder must be given notice and an opportunity for a hearing.

  • A certificate of occupancy must not be issued until the plumbing system has passed the final inspection; the certificate of occupancy is required before the building may be occupied.

  • The code official may issue a stop-work order if the work is being performed in violation of the code; the stop-work order must be in writing and must state the reason for the order.

  • A variance may be granted by the board of appeals if the strict application of the code would cause undue hardship; the variance must not compromise the health, safety, or welfare of the public.

  • The code official may assess penalties for violations of the code; the penalties may include fines, imprisonment, or both; each day of violation may be considered a separate offense.

Quick reference

Safety, Materials, and Special Plumbing Systems

  • The minimum thickness of a protective sleeve for a pipe passing through a concrete wall is 1/2 inch; the sleeve must be at least 2 inches larger in diameter than the pipe.

  • The minimum distance between a water service pipe and a sewer pipe is 10 feet horizontally or 18 inches vertically; the water pipe must be above the sewer pipe if the vertical separation is less than 18 inches.

  • The minimum distance between a water heater and combustible material is 6 inches for a gas-fired water heater; the water heater must be installed on a noncombustible floor or on a stand.

  • The minimum size of a grease interceptor is 10 gallons per minute for a single-compartment sink; the grease interceptor must be installed downstream of all fixtures that discharge grease.

  • The minimum size of a medical gas pipe is 1/2 inch; the pipe must be installed by a certified installer and must be tested in accordance with NFPA 99.

  • The minimum size of a fuel gas pipe is 1/2 inch; the pipe must be installed in accordance with the fuel gas code and must be tested at a pressure of at least 1.5 times the maximum working pressure.

  • The minimum size of a rainwater harvesting system pipe is 3/4 inch; the system must be protected against backflow and must be tested for leaks before being placed in operation.

  • The minimum size of a private sewage disposal system pipe is 4 inches; the system must be designed by a licensed engineer and must be approved by the authority having jurisdiction.