Cert III Electrician key terms
Cert III Electrician · Get comfortable with the vocabulary.
- Hierarchy of control
- Related: Risk assessment, Personal protective equipment, Isolation and lock-out
The ranked order of risk controls from most to least effective: eliminate the hazard, substitute it, use engineering controls, apply administrative controls, then use personal protective equipment as the last line of defence.
- Risk assessment
- Related: Hierarchy of control, Safe work method statement, Tag-out
A structured process of identifying hazards, judging how likely and how severe any harm could be, and deciding what controls are needed before work starts.
- Personal protective equipment
- Related: Hierarchy of control, Arc flash
Clothing and gear worn by a worker, such as insulated gloves, safety glasses, hearing protection and arc-rated clothing, that reduces exposure to hazards but does not remove them.
- Isolation and lock-out
- Related: Tag-out, Prove-test-prove, Test before you touch
The procedure of disconnecting all supply sources, proving the circuit dead, and fitting personal locks and danger tags so the installation cannot be re-energised while work proceeds.
- Tag-out
- Related: Isolation and lock-out, Hierarchy of control
Attaching a clearly written danger tag to an isolation point or control device to warn others that equipment must not be operated until the person who fitted the tag removes it.
- Test before you touch
- Related: Prove-test-prove, Isolation and lock-out
A safe working habit of verifying an installation or conductor is de-energised with a proven tester immediately before any contact, never relying on assumptions or labels alone.
- Safe work method statement
- Related: Risk assessment, Hierarchy of control
A written document describing how a high-risk construction task will be carried out, listing the hazards, the controls, and the sequence of steps workers must follow.
- Arc flash
- Related: Personal protective equipment, Isolation and lock-out
A sudden release of intense heat, light and pressure caused by an electrical fault through air between energised conductors, capable of causing severe burns and blast injury.
- Duty of care
- Related: Risk assessment, Notifiable incident
The legal obligation of a person conducting a business or undertaking, and of each worker, to take reasonable steps to protect health and safety so far as is reasonably practicable.
- Notifiable incident
- Related: Duty of care
A serious workplace event, such as a death, serious injury or dangerous electrical incident, that the regulator must be told about immediately after the site is made safe.
- Waste segregation
- Related: Environmental duty, Sustainable procurement
Sorting waste such as copper cable offcuts, fluorescent tubes, batteries, packaging and general rubbish into separate streams so each can be recycled or disposed of correctly.
- Environmental duty
- Related: Waste segregation, Sustainable procurement
The responsibility to prevent pollution and minimise harm to land, water and air from work activities, including correct handling and disposal of waste and hazardous substances.
- Ohm's law
- Related: Series circuit, Parallel circuit, Power formula
The relationship stating that voltage equals current multiplied by resistance, so any one value can be calculated when the other two are known in a circuit.
- Series circuit
- Related: Parallel circuit, Ohm's law
A circuit where components are connected end to end so the same current flows through each, while the supply voltage divides across the individual resistances.
- Parallel circuit
- Related: Series circuit, Ohm's law
A circuit where components are connected across the same two points, so each receives the full supply voltage while the total current divides between the branches.
- Power formula
- Related: Ohm's law, Power factor
The relationship that electrical power in watts equals voltage multiplied by current, and also equals current squared multiplied by resistance.
- Power factor
- Related: Power formula, Induction motor
The ratio of real power to apparent power in an alternating current circuit, indicating how much of the supplied current performs useful work rather than building magnetic fields.
- Alternating current
- Related: Direct current, Root mean square
An electric current that reverses direction periodically, typically many times each second, as supplied by the mains distribution network.
- Direct current
- Related: Alternating current
An electric current that flows continuously in one direction, as produced by batteries, solar panels and rectifier circuits.
- Root mean square
- Related: Alternating current, Multimeter
The effective value of an alternating quantity, equal to the direct value that would produce the same heating effect; for a sine wave it is the peak divided by about 1.414.
- Multimeter
- Related: Root mean square, Prove-test-prove
A test instrument combining voltage, current, resistance and often continuity measurement functions, selected by a rotary dial and connected to the circuit with test leads.
- Prove-test-prove
- Related: Test before you touch, Insulation resistance test, Multimeter
A testing sequence in which the instrument is checked on a known source before and after the actual test, confirming the tester worked and the reading can be trusted.
- Voltage drop
- Related: Cable current-carrying capacity, Derating factor
The reduction in voltage along a circuit caused by current flowing through conductor resistance, which must be limited so connected equipment receives adequate voltage.
- Cable current-carrying capacity
- Related: Derating factor, Voltage drop, Protective device coordination
The maximum continuous current a cable can carry under stated installation conditions without its insulation exceeding its rated temperature.
- Derating factor
- Related: Cable current-carrying capacity, Voltage drop
A multiplier below one applied to a cable's tabulated current rating to account for conditions such as grouping, ambient temperature, thermal insulation or installation method.
- Protective device coordination
- Related: Cable current-carrying capacity, Residual current device
Selecting and setting circuit breakers and fuses so that the device nearest a fault operates first, protecting the cable while limiting disruption to the rest of the installation.
- Residual current device
- Related: Earthing and bonding, Protective device coordination
A protective switch that compares current in the active and neutral conductors and trips when a small difference indicates leakage to earth, reducing electric shock risk.
- Earthing and bonding
- Related: Residual current device, Equipotential bonding
Connecting exposed conductive parts and the installation's earth system together and to the general mass of earth so fault current has a low-impedance path that operates protection.
- Equipotential bonding
- Related: Earthing and bonding
Joining conductive parts such as metal pipes, frames and earth bars so they sit at substantially the same potential, preventing dangerous voltage differences between them.
- Insulation resistance test
- Related: Prove-test-prove, Continuity test
A test applying a raised direct voltage between conductors and earth to measure insulation resistance and confirm the wiring is sound and dry before energising.
- Continuity test
- Related: Insulation resistance test, Earthing and bonding
A low-resistance check confirming that a conductor or protective earthing path is unbroken end to end, usually performed with a low-voltage ohmmeter.
- Single line diagram
- Related: As-built drawing, Schedule of circuits
A drawing using standard symbols to show the electrical supply, switchboards, protective devices and circuits of an installation in simplified form.
- As-built drawing
- Related: Single line diagram, Schedule of circuits
A drawing updated after construction to record the installation exactly as it was built, including any variations from the original design.
- Schedule of circuits
- Related: Single line diagram, As-built drawing
A table fixed at a switchboard listing each circuit, its rating, protective device, cable size and the equipment it supplies, supporting safe isolation and future work.
- Induction motor
- Related: Direct-on-line starter, Thermal overload
An alternating current motor in which a rotating magnetic field from the stator induces currents in the rotor, producing torque without brushes or direct electrical connection to the rotor.
- Direct-on-line starter
- Related: Induction motor, Thermal overload
A motor starting method that connects the motor directly to full supply voltage through a contactor, giving high starting current and simple control.
- Thermal overload
- Related: Induction motor, Direct-on-line starter
A protection device that trips a motor control circuit when sustained excess current heats a sensing element beyond a set level, preventing motor winding damage.
- Energy efficiency
- Related: Sustainable procurement, Demand management
Choosing equipment, lighting and control strategies that deliver the required service using less energy, lowering running costs and greenhouse gas emissions over the installation's life.
- Demand management
- Related: Energy efficiency, Power factor
Techniques such as load scheduling, power factor correction and automatic control that reduce peak demand and total consumption from the supply network.
- Sustainable procurement
- Related: Energy efficiency, Waste segregation
Selecting materials and equipment on whole-of-life criteria including energy use, durability, recyclability and responsible sourcing, not just purchase price.