Basic Scaffolding (SB) study materials
Basic Scaffolding (SB) study resources

Basic Scaffolding (SB) flashcards

Basic Scaffolding (SB) · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Standard
The vertical upright member of a scaffold that carries the load down to the base plate or sole board and into the ground or supporting structure.
Ledger
A horizontal tube running parallel to the building face that connects standards together and supports the transoms or bearers carrying the platform.
Transom
A horizontal member spanning between standards perpendicular to the wall; it supports the decking or putlogs and helps tie the two scaffold faces together.
Putlog scaffold
A scaffold whose inner ends of putlogs sit in holes in a masonry wall, so it depends on the wall for support and is not fully independent.
Sole board
A timber or steel pad placed under a base plate to spread the standard's load over a larger ground area and reduce settlement risk.
Base plate
The steel plate fixed to the foot of a standard that bears on the sole board and distributes the leg load over the bearing surface.
Scaffold tie
A connection from the scaffold to the structure that resists wind and lateral loads and prevents the scaffold from pulling away or overturning.
Guardrail height
The toprail is normally set between 0.9 and 1.15 metres above the platform, with a midrail and a toeboard of at least 100 mm.
Toeboard
A low board or barrier at the platform edge, at least 100 mm high, that stops tools and material from being kicked off the deck.
Mobile tower stability
A mobile tower needs locked castors and outriggers or stabilizers where specified; it must never be moved with persons or material on the platform.
Duty rating
The load class of a scaffold (light, medium, or heavy duty) that sets the maximum uniformly distributed load the platform is designed to carry.
Dead load
The permanent self-weight of the scaffold structure, decking, guardrails, and fixed attachments such as sheeting or signage.
Live load
The variable load from persons, tools, and stacked material on the platform, which must stay within the scaffold's duty rating.
Wind load
The force from wind pressure on the scaffold and any sheeting or netting; it rises with the square of wind speed and drives tie and brace design.
Point load
A concentrated load applied over a small area, such as a wheel of a barrow or a stacked pallet, which may exceed the UDL allowance locally.
Overloading signs
Warning signs include sagging or bowed ledgers, cracked decking, bent transoms, and visible deflection, which require immediate unloading and inspection.
Ground bearing check
Confirm the soil or surface can carry the leg loads; soft fill, backfill, and made ground need assessment and wider sole boards or an engineer's design.
Frost heave risk
Freezing and thawing of ground under a base can lift or settle the scaffold, so bases need drainage and re-inspection after cold weather.
Erection sequence
Set and level bases, erect standards and first ledgers, install bracing and ties, then add decking, guardrails, and access as the lifts rise.
Dismantling order
Dismantle from the top down: remove toeboards and guardrails, then decking, then ledgers and transoms, then standards, lowering components rather than dropping them.
Tie removal rule
Ties are removed only as dismantling descends past them; removing ties ahead of the work leaves the scaffold unstable in wind.
Method statement
A written, site-specific document describing the safe sequence, plant, access, and controls for erecting, altering, or dismantling the scaffold.
Ladder access rules
Access ladders extend about 1 m above the landing, are secured top and bottom, sit at roughly 1:4, and keep rungs clear of obstruction.
Fall arrest anchor
A verified anchorage point, ideally overhead, that keeps the lanyard clear of edges and swing-fall hazards and supports prompt rescue.
Rescue plan
A pre-arranged procedure and equipment to recover a worker suspended in a harness quickly, because suspension trauma can become life-threatening within minutes.
Scaffold tag system
Green tags mark scaffolds safe for use with date and inspector; red tags mark scaffolds do not use; tags must be current, legible, and fixed at access points.
Inspection triggers
Inspect before first use, after alteration, after impact or severe weather, and at the intervals set by the governing standard or site rules.
Coupler torque check
Right-angle and swivel couplers are tightened to the manufacturer's specified torque, commonly around 40-65 Nm, and verified with a torque wrench.
Defect examples
Bent or corroded tubes, cracked welds, missing couplers, loose base jacks, split decking, and missing toeboards are defects that remove a scaffold from service.
Duty holder duties
Employers and contractors must provide a safe workplace, competent persons, training, information, and risk assessments covering scaffold erection and use.
Competent person
A person with the training, experience, and knowledge to perform the scaffold task safely and to recognize and correct defects or unsafe conditions.
Design requirement
Complex, non-standard, or heavily loaded scaffolds need design by a competent engineer and a drawing showing ties, bracing, and loading limits.