Intermediate scaffolder licence
A high-risk work licence class authorising the holder to erect, alter, and dismantle the scaffold types specified in the national competency standard for that class, subject to any conditions.
Licence condition
A restriction or requirement attached to a licence, such as the scaffold types permitted or supervision required, which the holder must comply with at all times.
PCBU duty
The primary duty of a person conducting a business or undertaking to ensure health and safety so far as reasonably practicable, including safe scaffolding systems, training, and supervision.
Scaffold plan
A documented description of the scaffold type, dimensions, load class, foundation, ties, and access, prepared before erection and used to control the work.
Ground bearing check
Verification that the soil or surface under base plates can support the scaffold loads without excessive settlement, often requiring soleboards or engineered support.
Service clearance
The safe distance maintained between a scaffold and overhead or underground services such as powerlines, confirmed with the asset owner before work begins.
SWMS
A safe work method statement setting out the high-risk construction work, the hazards, the controls, and the review arrangements, required before work starts.
Plumb tolerance
The permitted deviation of a standard from vertical, specified by the manufacturer or design, commonly checked with a spirit level at each lift.
Tie installation
The fixing of scaffold ties to the structure at the spacing set by the design, installed progressively as erection proceeds to maintain stability.
Dismantling sequence
Removal of scaffold components in reverse order of erection, working from the top down, with ties removed only as the work descends.
Duty rating
The rated load a scaffold platform may carry, commonly light, medium, or heavy, set by the design and displayed at the access point.
Dead load
The permanent weight of scaffold components such as standards, ledgers, transoms, planks, and guardrails, which the design must support.
Live load
The variable load on a platform from workers, tools, and materials, which must not exceed the duty rating of the scaffold.
Wind load
The force on a scaffold from wind, affected by location, height, terrain, and permeability, used by the designer to set tie spacing and restrictions.
Soleboard
A timber or engineered pad under a base plate that spreads the standard load over a larger area to keep ground pressure within capacity.
Scaffold tag
A label at the access point recording the scaffold ID, duty rating, inspection date, inspector, and status such as safe, incomplete, or do not use.
Coupler torque
The tightening force applied to a scaffold coupler, checked with a torque wrench to the value specified by the manufacturer or design.
Post-event inspection
An inspection by a competent person after high wind, impact, or alteration, required before the scaffold is used again regardless of the normal inspection cycle.
Suspension trauma
A medical emergency that can develop within minutes when a person is suspended in a harness, requiring prompt rescue and monitoring.
Rescue plan
A documented, practised, and resourced procedure for recovering a fallen or suspended worker from a scaffold without delay.
Competent person
A person with the training, qualification, and experience to perform the specific scaffold task safely, verified through records and observation.
Toolbox talk
A short pre-work briefing communicating the scaffold plan, hazards, controls, and any changes to the crew before work begins.
Wind speed limit
The maximum wind speed at which a scaffold may be erected, used, or dismantled, set by the manufacturer or design, above which work stops.
Overhead protection
A fan, gantry, or catch platform installed where a scaffold adjoins a public way to protect people below from falling objects.
Scaffold register
A record of each scaffold's ID, design reference, duty rating, erection date, and inspection history, kept for compliance and audit.
Hierarchy of control
The order of risk controls from elimination and substitution through engineering and administrative controls to PPE as the last resort.
Dynamic risk assessment
A check at the start of each shift or task that identifies changes in conditions and confirms controls remain effective before work continues.
Component inspection
Pre-use and periodic checking of scaffold parts for damage or wear, with defective items tagged and removed from service.
Fall arrest system
Equipment that stops a fall, requiring a rated anchor, suitable lanyard, trained user, inspection, and a rescue plan.
Notifiable incident
A death, serious injury, or dangerous incident such as scaffold collapse that must be reported to the regulator immediately.
Height-to-base ratio
The relationship between a scaffold's height and its base dimensions, which governs stability and may require outriggers or a wider base.