NSW Electrical Licence · Get comfortable with the vocabulary.

Ohm's law

The fixed relationship in a resistive circuit where voltage equals current multiplied by resistance, so any one value can be calculated when the other two are known.

Related: Voltage drop, Impedance
Impedance

The total opposition a circuit presents to alternating current, combining resistance with reactance so that current and voltage may not peak together.

Related: Power factor, Ohm's law
Power factor

The ratio of real power to apparent power in an AC circuit, indicating how effectively current is being converted into useful work.

Related: Impedance, Apparent power
Apparent power

The product of root-mean-square voltage and current in an AC circuit, measured in volt-amperes and including both real and reactive components.

Related: Power factor, Impedance
Voltage drop

The reduction in voltage along a conductor caused by its resistance and current flow, which must be limited so equipment receives adequate voltage.

Related: Ohm's law, Cable current-carrying capacity
Three-phase supply

An AC supply using three conductors whose voltages are displaced by 120 electrical degrees, allowing efficient motor operation and balanced loading.

Related: Star-delta connection, Phase rotation
Star-delta connection

Two ways of connecting three-phase windings or loads, one giving higher voltage at lower current and the other lower voltage at higher current.

Related: Three-phase supply, Motor starter
Phase rotation

The order in which the three phase voltages reach their peaks, which determines the direction of rotation of three-phase motors.

Related: Three-phase supply, Motor starter
Cable current-carrying capacity

The maximum continuous current a conductor can carry under stated installation conditions without exceeding its rated temperature, after applying correction factors.

Related: Derating factor, Voltage drop
Derating factor

A multiplier applied to a cable's tabulated current rating to account for conditions such as ambient temperature, grouping, or thermal insulation.

Related: Cable current-carrying capacity, Thermal insulation rating
Thermal insulation rating

A reduced current rating applied when a cable is surrounded by thermal insulation, since heat cannot escape as readily and the conductor runs hotter.

Related: Derating factor, Cable current-carrying capacity
Installation method

The way a cable is fixed, buried, enclosed, or supported, which determines how effectively heat is dissipated and which current rating table applies.

Related: Cable current-carrying capacity, Derating factor
Equipotential bonding

Connecting conductive parts together so they sit at substantially the same potential, reducing the risk of shock between simultaneously accessible surfaces.

Related: Main earthing terminal, Earth fault loop impedance
Main earthing terminal

The designated bar or link in an installation where protective earth conductors, the earthing conductor, and bonding conductors are connected together.

Related: Equipotential bonding, Protective earthing
Protective earthing

Connecting exposed conductive parts of equipment to earth so that fault current flows and a protective device operates quickly to disconnect supply.

Related: Earth fault loop impedance, Residual current device
Earth fault loop impedance

The total impedance of the path taken by fault current from the source through the fault and back, which must be low enough for prompt disconnection.

Related: Protective earthing, Prospective fault current
Prospective fault current

The current that would flow at a point in an installation if a short circuit or low-impedance fault occurred there, used to select protective devices.

Related: Earth fault loop impedance, Circuit breaker
Residual current device

A protective device that continuously compares currents in active and neutral conductors and trips when an imbalance indicates current leaking to earth.

Related: Protective earthing, Circuit breaker
Circuit breaker

An automatically operated switch that opens a circuit on overload or short circuit and can be reset once the fault is corrected.

Related: Prospective fault current, Fuse
Fuse

A protective device containing a element that melts and opens the circuit when current exceeds its rating for a set time.

Related: Circuit breaker, Prospective fault current
Overload

A condition where current exceeds the normal operating value without a fault, and if sustained will overheat conductors and equipment.

Related: Circuit breaker, Cable current-carrying capacity
Double insulation

A construction where live parts are separated from accessible surfaces by both basic insulation and an additional independent layer of insulation.

Related: Class I appliance, Protective earthing
Class I appliance

Equipment that relies on basic insulation plus a protective earth connection to its exposed metal parts for protection against electric shock.

Related: Double insulation, Protective earthing
Ingress protection rating

A two-digit code describing how well an enclosure resists entry of solid objects and water, guiding suitability for a given environment.

Related: Class I appliance, Isolation
Isolation

Disconnecting all active conductors from supply and securing the disconnection so work can proceed without the risk of re-energisation.

Related: Lockout tagout, Prove dead
Prove dead

Confirming a circuit is de-energised using a tester that has been checked before and after the test to prove it is functioning.

Related: Isolation, Lockout tagout
Continuity test

A check that a conductive path is intact and has low resistance, commonly used for protective earth conductors and bonding connections.

Related: Insulation resistance test, Protective earthing
Insulation resistance test

A measurement applying a high DC voltage between conductors and earth to confirm insulation is sound and free of moisture or damage.

Related: Continuity test, Prove dead
Polarity test

A verification that active, neutral, and protective earth conductors are connected to the correct terminals throughout an installation.

Related: Continuity test, Isolation
Lockout tagout

A procedure using locks and warning tags on isolation points so a circuit cannot be re-energised while work is in progress.

Related: Isolation, Prove dead
Risk assessment

A structured process of identifying hazards, evaluating the likelihood and severity of harm, and deciding on controls before work begins.

Related: Hierarchy of control, Lockout tagout
Hierarchy of control

An ordered set of risk controls starting with eliminating the hazard, then substituting, engineering, administrative measures, and finally personal protective equipment.

Related: Risk assessment, Lockout tagout
Personal protective equipment

Clothing and equipment worn by a worker, such as gloves, eye protection, and insulated tools, as a last line of defence against hazards.

Related: Hierarchy of control, Risk assessment
Safe approach distance

The minimum distance a person or conductive object must keep from exposed live parts to avoid arc or contact hazards.

Related: Isolation, Risk assessment
Electrical licence

The authorisation issued by the regulator permitting a person to carry out electrical wiring work within defined scope and conditions.

Related: Certificate of compliance, Supervision
Certificate of compliance

A document completed by the licensed worker declaring that electrical work has been carried out and tested in accordance with requirements.

Related: Electrical licence, Compliance test
Supervision

The oversight a licensed electrical worker provides to less qualified persons, remaining responsible for the quality and safety of the work.

Related: Electrical licence, Certificate of compliance
Compliance test

The set of verification checks and measurements performed on completed work to confirm it meets the wiring rules before being placed in service.

Related: Certificate of compliance, Insulation resistance test