BPC Commercial Builder (Unlimited) flashcards
BPC Commercial Builder (Unlimited) · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Work Breakdown Structure
- A hierarchical decomposition of the total project scope into manageable deliverable packages. Each estimate line item maps to one WBS code so costs roll up without duplication.
- Total Float
- The amount of time an activity can be delayed without delaying project completion. Calculated as late start minus early start, or late finish minus early finish.
- Loaded Labor Rate
- The base hourly wage multiplied by one plus the burden rate. Burden includes payroll taxes, workers' compensation, insurance, and fringe benefits.
- Unit-Price Contract
- A contract paying a fixed price per unit of measured work. The owner bears quantity risk while the contractor bears unit-cost risk.
- Builder's Risk Insurance
- Coverage for the structure under construction, materials in transit and storage, and related soft costs from a covered loss. It excludes employee injury and third-party liability.
- Retainage
- A percentage withheld from each progress payment until substantial completion. It protects the owner against liens and defective work and is commonly five to ten percent.
- Soil Swell Factor
- The percentage increase in volume when bank soil is excavated and loosened. Loose volume equals bank volume multiplied by one plus the swell factor.
- Competent Person
- An individual capable of identifying existing and predictable hazards and authorized to take prompt corrective action. Required for daily excavation inspections under OSHA.
- Allowable Bearing Pressure
- The maximum soil pressure a foundation may impose, set by geotechnical report. Footing area must be large enough that service load divided by area stays below it.
- Water-Cement Ratio
- The ratio of water weight to cementitious material weight in a mix. Lower ratios increase strength and durability; it is the primary mix design control.
- Slip-Critical Connection
- A bolted steel connection designed to prevent slip at service loads. It requires pretensioned high-strength bolts and faying surfaces prepared to a specified slip coefficient.
- Board Foot
- A lumber volume unit equal to one square foot of one-inch-thick stock. Computed as nominal thickness times nominal width times length in feet, divided by twelve.
- Panel Span Rating
- A sheathing label showing maximum support spacing in inches, roof first then floor. A 24/16 rating allows twenty-four inches on roof and sixteen on floor.
- Mill Certificate
- A steel mill's certified report of chemical and mechanical properties for a heat of steel. It documents yield strength and is required for code compliance.
- Vapor Retarder Class
- A rating of resistance to water vapor diffusion. Class I is under 0.1 perm, Class II is 0.1 to 1.0, and Class III is 1.0 to 10 perms.
- Cricket
- A small sloped roof diverting water around a chimney or wall projection. Required behind chimneys wider than thirty inches to prevent ponding and leakage.
- U-Factor
- The overall rate of heat transfer through an assembly, equal to one divided by total R-value. Lower values indicate better insulating performance.
- Demand Factor
- The ratio of maximum demand to total connected load. Used to size electrical services because not all connected loads operate simultaneously.
- Fixture Unit
- A dimensionless measure of probable drainage or supply demand for a plumbing fixture. Fixture units are summed and converted to peak flow for pipe sizing.
- Voltage Drop
- The reduction in voltage along a conductor due to resistance. Kept under three percent on branch circuits and five percent total feeder plus branch.
- Fire-Rated Assembly
- A listed wall or floor system with a stated hourly rating. Board type, layers, stud size and spacing, and fastener schedule must match the listing exactly.
- Solar Heat Gain Coefficient
- The fraction of incident solar radiation admitted through glazing as heat. Lower values reduce cooling load in warm climates and are specified for south and west exposures.
- Clear Opening Width
- The unobstructed width through a door when open at ninety degrees. Egress doors typically require at least thirty-two inches of clear width.
- Personal Fall Arrest System
- A full-body harness, anchorage, and deceleration device limiting free fall to six feet. Anchorage must resist five thousand pounds per worker.
- Safety Data Sheet
- A standardized document listing a chemical's hazards, handling, and first-aid measures. It must be accessible to workers under hazard communication rules.
- Certificate of Occupancy
- An official document issued after final inspections confirm the building complies with approved plans and codes. It authorizes occupancy and use of the structure.
- Maximum Price Contract
- A cost-plus agreement with a guaranteed maximum price. The contractor absorbs costs above the cap, and savings below it are shared per a stated formula.
- Escalation
- An allowance for price increases between the estimate basis date and construction. Computed by compounding an annual rate over the elapsed months.
- Modular Brick
- A brick sized to produce a nominal four by two and two-thirds by eight inch module with three-eighths inch mortar joints. About six and three-quarter bricks cover one square foot of wall.
- Absolute Volume Method
- A concrete mix design procedure summing the volumes of cement, water, air, and aggregates to one cubic yard. It yields proportions for a target water-cement ratio.
- Drainage Plane
- The weather-resistive surface behind cladding that sheds water to the exterior. It requires through-wall flashing and weep holes at its base.
- Equal Friction Method
- A duct sizing technique assigning the same pressure drop per unit length to each duct section. Sizes are read from friction charts at a target rate per hundred feet.